Sharayu Nimonkar

Dr. Sharayu Nimonkar


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of International Society of Preventive and Community Dentistry
Verified
Journal Article
Open access
PDF file
SNSharayu Nimonkar
Sharayu Nimonkar
VBVikram M Belkhode
Vikram M Belkhode
SGSr Godbole
Sr Godbole
PNPranali Vinod Nimonkar
Pranali Vinod Nimonkar
TDTrupti Dahane
Trupti Dahane
SSSeema Sathe
Seema Sathe
Context: Infection control is an important concept in the present day practice of dentistry. Disinfection of dental impressions is part of the daily routine in a dental clinics. After disinfection, it is important that impressions remain dimensionally stable. Aim: The purpose of this study was to compare the effect of chemical disinfectants and ultraviolet (UV) disinfection on the dimensional stability of the polyvinyl siloxane impressions. Objectives: The objective of the study is (1) To evaluate the effect of chemical disinfectant (2% glutaraldehyde and 1% sodium hypochlorite) and UV disinfectant on the dimensional stability of polyvinyl siloxane impression material. (2) Comparative evaluation of the dimensional discrepancy between the cast poured from the polyvinyl impressions material, that is subjected to chemical disinfectant and UV disinfectant to that of cast poured from impressions that were nondisinfected. Materials and Methods: A customized tray was fabricated to make impressions. Impressions were divided into four groups, 10 samples were disinfected with 2% glutaraldehyde for 20 min, 10 samples were disinfected with 1% sodium hypochlorite for 20 min, 10 samples were disinfected with UV light for 20 min, and 10 samples were not subjected to disinfection which served as control group. All the samples were poured after 30 min in die stone. Measurements were recorded using traveling microscope of 0.001 accuracy. Statistical analysis used in this study was the one-way ANOVA test. Results: The result showed significant dimensional changes in samples disinfected with 2% glutaraldehyde and 1% sodium hypochlorite, whereas samples disinfected with UV disinfectant unit showed no significant dimensional changes when compared with control group samples. Within the chemical groups, impressions disinfected with 1% sodium hypochlorite showed more discrepancy in the dimensions when compared to the 2% glutaraldehyde disinfected group. Conclusions: UV light disinfectant can be safely used to disinfect impressions as compared to chemical disinfectants in clinical prosthodontic procedures.

30 July 2022 in Cureus
Verified
Journal Article
Open access
SPSweta G. Pisulkar
Sweta G. Pisulkar
RMRohit A Mistry
Rohit A Mistry
SNSharayu Nimonkar
Sharayu Nimonkar
CDChinmayee Dahihandekar
Chinmayee Dahihandekar
GPGajanan Pisulkar
Gajanan Pisulkar
VBVikram Belkhode
Vikram Belkhode
Osteoporosis has been an enigma in terms of the administration of implant therapy. It has been implicated as a cause of implant failure as it directly affects the quality of the bone. The diagnosis of osteoporosis is mainly done by measuring skeletal bone mineral density (BMD). During implant therapy, the BMD of jaws can be evaluated on routine orthopantomogram (OPG) or cone beam CT (CBCT). The various advantages of CBCT include establishing a correlation between skeletal bone density and bone density of jaws and estimating its effect on implant stability in osteoporotic patients, which in turn will help in determining the prognosis of the implant in osteoporotic patients. This review is a summary of all patient-related studies conducted in the mentioned context of implant placement in patients with osteoporosis, treatment modalities, and prognosis. We performed a search of relevant articles on Google Scholar, PubMed, and Cochrane, which yielded a total of 25 articles for full-text reviews. After excluding some articles based on the exclusion criteria, a review was conducted along with a pilot study on implant placement in osteoporotic patients. Regional bone density can be a helpful parameter in predicting primary implant stability and it can be a useful indicator of skeletal BMD. With a careful evaluation of BMD, dental implants can be placed in patients with osteoporosis with a better prognosis for the treatment.

1 January 2020 in The Journal of Indian Prosthodontic Society
Verified
Journal Article
Open access
PDF file
SNSharayu Nimonkar
Sharayu Nimonkar
SSSeema Sathe
Seema Sathe
SPSweta Pisulkar
Sweta Pisulkar
VBVikram Belkhode
Vikram Belkhode
ABAnjali Borle
Anjali Borle
Aim: To evaluate different methods, techniques, and concepts documented in the literature to assess iris positioning accurately to the related dimensions needed to effectuate maxillofacial rehabilitation of ocular prosthesis. Settings and Design: This systematic review was conducted as per the PRISMA guidelines which is the most opted reporting protocol. Materials and Methods: Two electronic databases PubMed and Cochrane Library) were searched for manuscripts published from 1969 till September 30, 2019. An electronic search (of peer review restricted to English language dental literature was conducted to identify the relevant scientific article on iris positioning in maxillofacial prostheses. Two observers independently read the abstracts and selected 17 full text articles fulfilling the inclusion criteria. Statistical Analysis Used: No meta-analysis was conducted due to heterogeneity of data obtained. Results: All the 17 documented articles related to determination of the iris positioning to perform maxillofacial prosthetic rehabilitation depicting the use of a strip of plastic template, a Boley's gauge, a millimeter ruler, a pupillometer, window light, an ocular locator with fixed caliper, inverted anatomic tracings, a transparent graph grid were reviewed systematically. Conclusion: Currently, there is no evidence in the form of a systematic review of the available literature discussing the best technique available for perfectly matching the iris positioning. However, the latest techniques making use of digital technology such as digital photography, is believed to be more precise for iris positioning in the ocular prosthesis.

16 February 2022 in Trials
Verified
Journal Article
Open access
PDF file
VBVikram Belkhode
Vikram Belkhode
SGSurekha Godbole
Surekha Godbole
SNSharayu Nimonkar
Sharayu Nimonkar
PNPranali Nimonkar
Pranali Nimonkar
SPSweta Pisulkar
Sweta Pisulkar
Background: Obstructive sleep apnea (OSA) is due to the obstruction of the upper airway during sleep. This condition is often associated with multiple symptoms and co-morbidities. There are many treatment options mentioned in the literature to manage OSA, among which interventional option of continuous positive airflow (CPAP) and non-interventional option, i.e., mandibular advancement device (MAD), which is an oral appliance (OA), are the most preferred ones. This study aims to evaluate the efficacy of customized maxillary oral appliances with mandibular advancement devices in moderate OSA patients.Methods: A prospective interventional study with a randomized controlled trial will be carried out involving 40 participants (sample size), with an apnea-hypopnea index (AHI) > 15–30, recorded on polysomnography (PSG). Study participants will be randomly divided into the following treatment groups: control group or group subjected to mandibular advancement device (MAD,n=20) and second group subjected to customized maxillary oral appliance (CMOA,n=20). Baseline assessment of apnea/hypopnea index (AHI), oxygen saturation in blood, percentage of rapid eye movement, electroencephalogram, electrocardiogram, oro-nasal airflow via a pressure transducer, and Epworth Sleepiness Scale will be done. Then both study group participants will receive their respective appliances. And after one month and three months of delivery of the appliance, all the parameters, i.e., AHI, oxygen saturation in blood, percentage of rapid eye movement, electroencephalogram, electrocardiogram, oro-nasal airflow via a pressure transducer, and Epworth Sleepiness Scale will be re-evaluated and compared with the baseline measurements. Descriptive and analytical statistics will be done. SPSS (Statistical Package for Social Sciences) Version 20.1 will be used as statistical software. The statistical significance between the two groups after one month and three months will be evaluated atp< 0.05.Discussion: We expect, customized maxillary oral appliance to be more efficient in managing moderate OSA, in comparison with MAD. If the hypothesis of the present study is confirmed, then this customized maxillary appliance will be quoted as a “gold standard” for managing moderate OSA.Trial registration: CTRI/2020/07/026936Registered 31 July 2020.

1 April 2020 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
SGSurekha Godbole
Surekha Godbole
SSSeema Sathe
Seema Sathe
SPSweta Pisulkar
Sweta Pisulkar
SNSharayu Nimonkar
Sharayu Nimonkar
VBVikram M Belkhode
Vikram M Belkhode
PNPranali V Nimonkar
Pranali V Nimonkar
To evaluate the change in color of the maxillofacial silicone after curing using a mobile phone colorimeter application. A two-piece metal mold was fabricated. Twenty five samples were made using M511, maxillofacial silicone. A jig was prepared to hold the mobile phone at a fix distance from the samples. The color was measured for each sample in terms of HSV (hue, saturation, value) with the mobile phone colorimeter application after manipulation and after polymerization of the samples. Data were statistically analyzed using the Student's paired t test and the software used in the analysis was SPSS 22.0 version. The mean difference of hue was 1.32 ± 2.71, with p value 0.053. Mean differences in saturation was 0.72 ± 2.01, with p value 0.066. Mean differences in value were 2.16 ± 3.11, with a p value 0.002. The measure of value showed statistically significant differences (p < 0.05). There was a significant change in the value of the color of the maxillofacial silicone after polymerization. Increasing the value of the color by 2-3% at the time of manipulation of the maxillofacial silicone with the use of a mobile phone colorimeter application can help the clinician to reproduce the same color in the final prosthesis after curing to achieve a predictable esthetic outcome for a facial prosthesis.

1 January 2023 in The Journal of Indian Prosthodontic Society
Verified
Journal Article
Open access
SNSharayu Nimonkar
Sharayu Nimonkar
VBVikramMurlidhar Belkhode
VikramMurlidhar Belkhode
CDChinmayee Dahihandekar
Chinmayee Dahihandekar
PNPranaliVinod Nimonkar
PranaliVinod Nimonkar
SPSweta Pisulkar
Sweta Pisulkar
Task for a prosthodontist. The custom-made ocular prostheses are preferred over the prefabricated stock eye shells as it provides intimate contact with the tissue bed, enabling an ideal fit. For an esthetic ocular prosthesis, the precise positioning of an iris is a primary requirement to avoid the squint eye appearance. Various case reports are documented in the literature for centralizing the iris in the prosthetic eye. This review article explores the established methods and techniques for positioning the iris in a custom-made ocular prosthesis....