Hong Seok Kim

Dr. Hong Seok Kim

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
JHJeremy T. Hines
Jeremy T. Hines
WJWoo-Lam Jo
Woo-Lam Jo
QCQuanjun Cui
Quanjun Cui
MMMichael A. Mont
Michael A. Mont
KKKyung-Hoi Koo
Kyung-Hoi Koo
JPJung-Wee Park
Jung-Wee Park
Hines JT, et al. J Korean Med Sci. 2021 May;36(24):e177. https://doi.org/10.3346/jkms.2021.36.e177

1 January 2020 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
HKHong Seok Kim
Hong Seok Kim
JPJung Wee Park
Jung Wee Park
SMSun-Young Moon
Sun-Young Moon
YLYoung-kyun Lee
Young-kyun Lee
YHYong-Chan Ha
Yong-Chan Ha
KKKyung-Hoi Koo
Kyung-Hoi Koo
Kim HS, et al. J Korean Med Sci. 2020 Nov;35(49):e410. https://doi.org/10.3346/jkms.2020.35.e410

15 November 2021 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
HKHong Seok Kim
Hong Seok Kim
JPJung Wee Park
Jung Wee Park
JHJoo Hyung Ha
Joo Hyung Ha
YLYoung-kyun Lee
Young-kyun Lee
YHYong-Chan Ha
Yong-Chan Ha
KKKyung-Hoi Koo
Kyung-Hoi Koo
Background: Long-term follow-up results of ceramic-on-ceramic (COC) total hip arthroplasty (THA), specifically, in patients with osteonecrosis of the femoral head (ONFH) are unknown. We evaluated (1) clinical results and radiological outcomes, (2) ceramic-related complications: noise and ceramic fracture, (3) osteolysis, and (4) survivorship after alumina COC THA in ONFH patients with longer than 10-year follow-up. Methods: From May 2003 to June 2009, 325 ONFH patients (403 hips) underwent primary THAs at our department. Among them, 231 patients (293 THAs) were followed for 10 to 16 (mean, 12.9) years. There were 148 men and 83 women, their mean age at the time of THA was 47.2 years, and their mean body index was 24.0 kg/m2. The postoperative CT scans were done in 160 hips. Results: Grinding sensation or squeak was noted in 6.8% (20/293), ceramic head fracture occurred in 2.4% (7/293) and acetabular osteolysis developed in 0.7% (2/293). All 7 ceramic fractures occurred in 28-mm short-neck heads. There was no detectable wear or prosthetic loosening, and the 16-year survivorship was 96.0% (95% confidence interval; 93.8% to 98.2%). The mean Harris hip score was 91.7 (range, 84 to 100) points at the final follow-up. Conclusions: The 10- to 16-year results of alumina COC THAs were encouraging with an excellent survivorship. However, ceramic fracture and noise still remain matters of concern. We recommend not to use 28-mm short-neck ceramic head to avoid ceramic head fractures. Level of Evidence: III

1 January 2014 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
HKHong Seok Kim
Hong Seok Kim
YJYan Jin
Yan Jin
MCMin-Ho Choi
Min-Ho Choi
JKJae-Hwan Kim
Jae-Hwan Kim
YLYoung Ha Lee
Young Ha Lee
SHSung-Tae Hong
Sung-Tae Hong
Kim HS, et al. J Korean Med Sci. 2014 Dec;29(12):1618-1625. https://doi.org/10.3346/jkms.2014.29.12.1618

28 September 2022 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
JPJung-Wee Park
Jung-Wee Park
HKHong Seok Kim
Hong Seok Kim
SPSojeong Park
Sojeong Park
SKSung Hwa Kim
Sung Hwa Kim
YLYoung-kyun Lee
Young-kyun Lee
KKKyung-Hoi Koo
Kyung-Hoi Koo
Park JW, et al. Clin Orthop Surg. 2022 Sep;14:e69. https://doi.org/10.4055/cios22027

26 October 2021 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
HKHong Seok Kim
Hong Seok Kim
JPJung-Wee Park
Jung-Wee Park
SLSoong Joon Lee
Soong Joon Lee
YLYoung-kyun Lee
Young-kyun Lee
YHYong-Chan Ha
Yong-Chan Ha
KKKyung-Hoi Koo
Kyung-Hoi Koo
Background: Recently, impingement between the femoral stem and ceramic liner, which appears as a notch in the stem neck on radiographs, has emerged as a new complication. However, the proportion of impingement, potential risk factors, and related complications are poorly elucidated. Question/purposes: In patients who underwent ceramic-on-ceramic (CoC) THA and had at least 10 years of follow-up, we asked: (1) What proportion had radiographic evidence of stem neck–ceramic liner impingement (notching of the stem), and what implant design, implantation factors, or complications such as ceramic fracture or metallosis are associated with impingement? (2) How common are the complications of noise and ceramic fracture? (3) What are the radiologic changes (including fixation of femoral and acetabular components, osteolysis, and heterotopic ossification) and clinical outcomes as determined by the modified Harris hip score (mHHS) for this cohort? (4) What is the survivorship with implant revision as the endpoint and with reoperation for any reason as the endpoint after CoC THA using a thick-neck stem design? Methods: Between May 2003 and April 2010, 643 patients underwent primary THA at a tertiary referral hospital. After excluding patients with metal-on-polyethylene and with ceramic-on-polyethylene implants, 621 patients were considered eligible for this study. All patients received the same hemispherical titanium cup, a standard-length tapered titanium stem, and a CoC bearing. Of those, 19% (115) were lost to follow-up before 10 years, and 8% (50) were excluded because they died before the minimum follow-up duration of 10 years, leaving 73% (456) for analysis. Patients had a mean age of 50 ± 14 years and were followed for a median (range) of 13 years (10 to 17). The mean cup abduction was 38° ± 5°, and the mean cup anteversion was 26° ± 7°. To determine the proportion of patients with the neck-liner impingement, we analyzed the plain radiographs of every patient during follow-up to detect notches around the stem. The detection of stem neck notches on the radiographs was reliable (intraobserver reliability: κ = 0.963; p < 0.001 and interobserver reliability: κ = 0.975; p < 0.001). To evaluate factors related to notching, we compared the possible confounding factors including gender, age, BMI, implant position, neck length, and head diameter. Complications such as ceramic fracture, noise, dislocation, and periprosthetic joint infection were recorded. Noise was evaluated via interview and with the Hip Noise Assessment Questionnaire, which assessed the noise qualitatively. For clinical outcome, we assessed the mHHS, which includes pain and function scales (0 [worst] to 100 [best]), every visit. Tilting of at least 4° or migration of at least 4 mm was the criteria for cup loosening; subsidence more than 3 mm, any change in position, or a continuous radiolucent line greater than 2 mm was the criteria for stem loosening. To evaluate osteolysis, we performed CT scans in 57% (262 of 456) of patients. Kaplan-Meier survivorship analysis was performed using the endpoints of survivorship free from implant revision and survivorship free from reoperation for any cause. Results: The proportion of stem neck notching was 11% (49 of 456). There were no differences in cup abduction and anteversion between hips with notches and those without notches. Notched hips were more likely to have 28-mm than 32-mm heads (90% [44 of 49] versus 70% [285 of 407]; odds ratio 3.77 [95% CI 1.46 to 9.73]; p = 0.004). None of the 49 notched hips had a ceramic head or liner fracture or evidence of metallosis. A ceramic head fracture was reported in 2% (9 of 456); all fractures occurred in 28-mm short neck heads. A ceramic liner fracture occurred in 0.2% (1 of 456), and noise was noted in 6% (27 of 456). Acetabular osteolysis developed in 2% (7 of 456). The mHHS was 91 ± 12 points at the final follow-up. The survivorship free from implant revision was 97% (95% CI 96% to 99%), and the survivorship free from reoperation for any cause was 96% (95% CI 95% to 98%) at 13 years. Conclusion: The proportion of stems with neck–ceramic liner impingement and ceramic component fracture were unacceptably high after the use of a thick-neck stem design, especially when a 28-mm head was used. We have discontinued the use of this stem design and we recommend that such stems should not be used when CoC bearings are used. As these findings might be generalized to other bearing couples, further studies focused on polyethylene liner wear and local metallosis due to thick stem neck are warranted. Level of Evidence: Level III, therapeutic study.