In this study, the electric field signatures of negative ground flashes pertinent to the Swedish thunderstorms were recorded simultaneously during the summer of 2014 using wide (up to 100 MHz) and narrow (at 3 MHz and 30 MHz as central frequencies) bandwidth antenna systems. The electric field signatures were recorded for a time duration of 250 ms. In the analysis, the whole flash was considered and a total of 98 flashes were chosen where electric field signatures of all wideband, 3 MHz and 30 MHz signals were present. It is observed that preliminary breakdown pulses are stronger radiators at 3 and 30 MHz compared to the return strokes. A comparison of our results with those of the previous studies obtained from different geographical regions clearly shows that the strength of preliminary breakdown pulses is higher in the temperate region (Sweden for instance) and is a function of latitude.
In this study, electromagnetic field radiation bursts known as chaotic pulse trains (CPTs) and regular pulse trains (RPTs) generated by lightning flashes were analyzed. Through a numerical analysis it was found that a typical CPT could be generated by superimposing several RPTs onto each other. It is suggested that the chaotic pulse trains are created by a superposition of several regular pulse trains. Since regular pulse trains are probably created by dart or dart-stepped leaders or K-changes inside the cloud, chaotic pulse trains are caused by the superposition of electric fields caused by more than one of these leaders or K-changes propagating simultaneously. The hypothesis is supported by the fact that one can find regular pulse trains either in the beginning, middle or later stages of chaotic pulse trains.
This paper presents the characteristics of the preliminary breakdown pulses (PBP) in 51 positive ground flashes recorded during 2014 summer thunderstorms in Sweden. Electric field measurements were conducted remotely using a broadband antenna system (up to 100 MHz) for a recording length of 1 s with 200 ms trigger time. In the analysis, PBP trains were observed in 86% of the cases. Based on the number of trains preceding the first return stroke, the PBP were classified into single and multiple train PBP. Characteristics of the first PBP train were determined and based on the initial polarity of the pulses, three types of PBP were identified. Characteristics of the subsequent PBP trains in the multiple train PBP were also analyzed and they were compared with the first PBP train. Based on the conceptual charge cloud configuration, we found that the inverted dipole is consistent with our observation. We also found that PBP in positive ground flashes during summer thunderstorms in Sweden are weak since the average ratios of the PBP peak to the first return stroke peak lie only between 0.21 and 0.26. Possible reasons for no detection of PBP and the different types of PBP observed were also discussed.
1 December 2017 in Electric Power Systems Research