Paul Oakley

Dr. Paul Oakley

Private Practice, Department of Kinesiology and Health Sciences, York University, Toronto, ON, Canada
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Journal of Physical Therapy Science
Verified
Journal Article
Open access
PDF file
Paul OakleyPaul Oakley
Paul Oakley
NENiousha Navid Ehsani
Niousha Navid Ehsani
IMIbrahim M. Moustafa
Ibrahim M. Moustafa
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
[Purpose] To systematically review the literature on the use of cervical extension traction methods for increasing cervical lordosis in those with hypolordosis and cervical spine disorders. [Methods] Literature searches for controlled clinical trials were performed in Pubmed, PEDro, Cochrane, and ICL databases. Search terms included iterations related to the cervical spine, neck pain and disorders, and extension traction rehabilitation. [Results] Of 1,001 initially located articles, 9 met the inclusion/exclusion criteria. The trials demonstrated increases in radiographically measured lordosis of 12–18°, over 5–15 weeks, after 15–60 treatment sessions. Untreated controls/comparison groups not receiving extension traction showed no increase in cervical lordosis. Several trials demonstrated that both traction and comparison treatment groups experienced immediate pain relief. Traction treatment groups maintained their pain and disability improvements up to 1.5 years later. Comparative groups not receiving lordosis improvement experienced regression of symptoms towards pre-treatment values by 1 years’ follow-up. [Conclusion] There are several high-quality controlled clinical trials substantiating that increasing cervical lordosis by extension traction as part of a spinal rehabilitation program reduces pain and disability and improves functional measures, and that these improvements are maintained long-term. Comparative groups who receive multimodal rehabilitation but not extension traction experience temporary relief that regresses after treatment cessation.

1 April 2020 in Dose-Response
Verified
Journal Article
Open access
PDF file
Paul OakleyPaul Oakley
Paul Oakley
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
ALARA is the acronym for “As Low As Reasonably Achievable.” It is a radiation protection concept borne from the linear no-threshold (LNT) hypothesis. There are no valid data today supporting the use of LNT in the low-dose range, so dose as a surrogate for risk in radiological imaging is not appropriate, and therefore, the use of the ALARA concept is obsolete. Continued use of an outdated and erroneous principle unnecessarily constrains medical professionals attempting to deliver high-quality care to patients by leading to a reluctance by doctors to order images, a resistance from patients/parents to receive images, subquality images, repeated imaging, increased radiation exposures, the stifling of low-dose radiation research and treatment, and the propagation of radiophobia and continued endorsement of ALARA by regulatory bodies. All these factors result from the fear of radiogenic cancer, many years in the future, that will not occur. It has been established that the dose threshold for leukemia is higher than previously thought. A low-dose radiation exposure from medical imaging will likely upregulate the body’s adaptive protection systems leading to the prevention of future cancers. The ALARA principle, as used as a radiation protection principle throughout medicine, is scientifically defunct and should be abandoned.

1 April 2019 in Dose-Response
Verified
Journal Article
Open access
PDF file
Paul OakleyPaul Oakley
Paul Oakley
NENiousha Navid Ehsani
Niousha Navid Ehsani
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
X-rays have been the gold standard for diagnosis, evaluation, and management of spinal scoliosis for decades as other assessment methods are indirect, too expensive, or not practical in practice. The average scoliosis patient will receive 10 to 25 spinal X-rays over several years equating to a maximum estimated dose of 10 to 25 mGy. Some patients, those getting diagnosed at a younger age and receiving early and ongoing treatments, may receive up to 40 to 50 X-rays, approaching at most 50 mGy. There are concerns that repeated radiographs given to patients are carcinogenic. Some studies have used the linear no-threshold model to derive cancer-risk estimates; however, it is invalid for low-dose irradiation (ie, X-rays); these estimates are untrue. Other studies have calculated cancer-risk ratios from long-term health data of historic scoliosis cohorts. Since data indicate reduced cancer rates in a cohort receiving a total radiation dose between 50 and 300 mGy, it is unlikely that scoliosis patients would get cancer from repeated X-rays. Moreover, since the threshold for leukemia is about 1100 mGy, scoliosis patients will not likely develop cancers from spinal X-rays. Scoliosis patients likely have long-term health consequences, including cancers, from the actual disease entity itself and not from protracted X-ray radiation exposures that are essential and indeed safe.

9 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAisha Salim Al Suwaidi
Aisha Salim Al Suwaidi
Ibrahim Moustafa Abu AmerIbrahim Moustafa Abu Amer
Ibrahim Moustafa Abu Amer
MKMeeyoung Kim
Meeyoung Kim
Paul OakleyPaul Oakley
Paul Oakley
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
Forward head posture (FHP) is a common postural displacement that is significantly associated with neck pain, with higher risks of having neck pain in female and older populations. This study investigated the effect of two different forward head posture (FHP) interventions in elderly participants with poor posture and non-specific neck pain. Sixty-six elderly participants with a craniovertebral angle (CVA) < 50° were randomized into either a Chiropractic Biophyics® (CBP®) or a standardized exercise based FHP correction group (Standard Group). Both groups were treated for 18 sessions over a 6-week period. A 3-month post-treatment follow-up was also assessed with no further interventions. The CBP group received a mirror image® exercise and a Denneroll™ cervical traction orthotic (DCTO); the standard group performed a protocol of commonly used stretching and strengthening exercises for the neck. Both groups received 30 min of their respective interventions per session. The primary outcome was the CVA, with secondary outcomes including pain intensity, Berg balance score (BBS), head repositioning accuracy (HRA), and cervical range of motion (CROM). After 18 sessions (6 weeks later), the CBP group had statistically significant improvement in the CVA (p < 0.001), whereas the standard group did not. In contrast, both groups showed improved functional measurements on the BBS and HRA as well as improved pain intensity. However, at the 3-month follow-up (with no further treatment), there were statistically significant differences favoring the CBP group for all outcomes (p < 0.001). The differences in the between group outcomes at the 3-month follow-up indicated that the improved outcomes were maintained in the CBP group, while the standard group experienced regression of the initially improved outcomes at 6 weeks. It is suggested that the improvement in the postural CVA (in the CBP group but not in the standard group) is the driver of superior and maintained pain and functional outcomes.

1 April 2018 in Dose-Response
Verified
Journal Article
Open access
PDF file
Paul OakleyPaul Oakley
Paul Oakley
JCJerry M. Cuttler
Jerry M. Cuttler
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
To remedy spine-related problems, assessments of X-ray images are essential to determine the spine and postural parameters. Chiropractic/manual therapy realignment of the structure of the spine can address a wide range of pain, muscle weakness, and functional impairments. Alternate methods to assess such spine problems are often indirect and do not reveal the root cause and could result in a significant misdiagnosis, leading to inappropriate treatment and harmful consequences for the patient. Radiography reveals the true condition and alignment of the spine; it eliminates guesswork. Contemporary approaches to spinal rehabilitation, guided by accurate imaging, have demonstrated superiority over primitive treatments. Unfortunately, there are well-meaning but misguided activists who advocate elimination or minimization of exposures in spine radiography. The radiation dose employed for a plain radiograph is very low, about 100 times below the threshold dose for harmful effects. Rather than increasing risk, such exposures would likely stimulate the patient’s own protection systems and result in beneficial health effects. Spine care guidelines need to be revised to reflect the potential benefits of modern treatments and the lack of health risks from low X-ray doses. This would encourage routine use of radiography in manual spine therapy, which differs from common pharmacologic pain relief practice.

1 April 2018 in Dose-Response
Verified
Journal Article
Open access
PDF file
Paul OakleyPaul Oakley
Paul Oakley
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
Evidence-based contemporary spinal rehabilitation often requires radiography. Use of radiography (X-rays or computed tomography scans) should not be feared, avoided, or have their exposures lessened to decrease patient dose possibly jeopardizing image quality. This is because all fears of radiation exposures from medical diagnostic imaging are based on complete fabrication of health risks based on an outdated, invalid linear model that has simply been propagated for decades. We present 7 main arguments for continued use of radiography for routine use in spinal rehabilitation: (1) the linear no-threshold model for radiation risk estimates is invalid for low-dose exposures; (2) low-dose radiation enhances health via the body’s adaptive response mechanisms (ie, radiation hormesis); (3) an X-ray with low-dose radiation only induces 1 one-millionth the amount of cellular damage as compared to breathing air for a day; (4) radiography is below inescapable natural annual background radiation levels; (5) radiophobia stems from unwarranted fears and false beliefs; (6) radiography use leads to better patient outcomes; (7) the risk to benefit ratio is always beneficial for routine radiography. Radiography is a safe imaging method for routine use in patient assessment, screening, diagnosis, and biomechanical analysis and for monitoring treatment progress in daily clinical practice.