Noel Keijsers

Dr. Noel Keijsers

Sint Maartenskliniek, Department of Research & Innovation, Nijmegen, The Netherlands;

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Clinical Biomechanics
Verified
Journal Article
Closed access
NKNoel Keijsers
Noel Keijsers
NSN.M. Stolwijk
N.M. Stolwijk
JLJ.W.K. Louwerens
J.W.K. Louwerens
JDJ. Duysens
J. Duysens

27 December 2022 in Disability and Rehabilitation
Verified
Journal Article
Closed access
CECarmen Joanne Ensink
Carmen Joanne Ensink
NKNoel Keijsers
Noel Keijsers
BGBrenda E. Groen
Brenda E. Groen
The System Usability Scale (SUS) is the most commonly used questionnaire to assess usability of healthcare innovations but is not available in Dutch (D-SUS). This study aims to translate the SUS to... Successful implementation of new rehabilitation technologies is partially dependent on good system usability.The System Usability Scale is translated to Dutch (D-SUS) to evaluate usability of healt...

1 January 2009 in Journal of Biomechanics
Verified
Journal Article
Closed access
NKNoel Keijsers
Noel Keijsers
Niki StolwijkNiki Stolwijk
Niki Stolwijk
BNB. Nienhuis
B. Nienhuis
JDJ. Duysens
J. Duysens

1 January 2010 in Gait & Posture
Verified
Journal Article
Closed access
NKNoel Keijsers
Noel Keijsers
NSN.M. Stolwijk
N.M. Stolwijk
TPT.C. Pataky
T.C. Pataky

11 December 2019 in Spinal Cord Series and Cases
Verified
Journal Article
Open access
PDF file
FHF. H. M. van Herpen
F. H. M. van Herpen
RDR. B. van Dijsseldonk
R. B. van Dijsseldonk
HRH. Rijken
H. Rijken
NKNoel Keijsers
Noel Keijsers
JLJ. W. K. Louwerens
J. W. K. Louwerens
INIlse van Nes
Ilse van Nes
Introduction Powered robotic exoskeletons are a promising solution to enable standing and walking in patients with spinal cord injury (SCI). Although training and walking with an exoskeleton in motor complete SCI patients is considered safe, the risks of unexpected (technical) adverse events and the risk of fractures are not fully understood. This article reports the occurrence of two different cases of bone fracture during exoskeleton usage. Furthermore, advice is given for extra safety training and instructions. Case presentation The first case concerns a 47-year-old woman with T12 AIS A SCI. Her exoskeleton shut down unexpectedly probably causing a misalignment of the joints of her lower extremities relative to the joints of the exoskeleton, which resulted in a fracture of her left tibia. The second case involves a 39-year-old man with L1 AIS B SCI. An unexpected fracture of the right distal tibia occurred without a specific prior (traumatic) incident. Discussion Exoskeleton training instructors, SCI patients and their buddies should be instructed how to handle emergency situations. Furthermore, they should be aware of the risk of stress fractures of the lower extremities. Proper alignment of the exoskeleton relative to the body is of utmost importance to reduce fracture risk. In the case of swelling and discoloring of the skin, radiographic examination should be performed in order to exclude any fracture.

4 April 2022 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Open access
INIlse van Nes
Ilse van Nes
RDRosanne B. van Dijsseldonk
Rosanne B. van Dijsseldonk
FHFrank H.M. van Herpen
Frank H.M. van Herpen
HRHennie Rijken
Hennie Rijken
AGAlexander C.H. Geurts
Alexander C.H. Geurts
NKNoel Keijsers
Noel Keijsers
To examine changes in quality of life (QoL) after an eight-week period of robotic exoskeleton training in a homogeneous group of patients with chronic complete spinal cord injury (SCI).Prospective ...