Xiao Peng

Dr. Xiao Peng


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2019 in European Journal of Inorganic Chemistry
Verified
Journal Article
Closed access
PDF file
JCJing‐Jing Chen
Jing‐Jing Chen
YXYao‐Chun Xu
Yao‐Chun Xu
ZGZhi‐Liang Gan
Zhi‐Liang Gan
XPXiao Peng
Xiao Peng
XYXiao‐Yi Yi
Xiao‐Yi Yi

20 September 2019 in RSC Advances
Verified
Journal Article
Open access
PDF file
YLYongping Li
Yongping Li
YYYufeng Yuan
Yufeng Yuan
XPXiao Peng
Xiao Peng
JSJun Song
Jun Song
JLJunxian Liu
Junxian Liu
Junle QuJunle Qu
Junle Qu
This study proposed a novel Fano resonance (FR) biosensor with ultrahigh detection sensitivity by integrating two dimensional (2D) hexagonal boron nitride (h-BN) nanosheets with a plasmonic silver film–silicon hybrid nanostructure. Owing to its ultralow-loss in surface plasmon polaritons (SPPs), 2D h-BN nanosheets can act as a planar photon waveguide (PWG) for generating energy level splitting. Notably, both asymmetric FR sharp lines and plasmon induced transparency (PIT) can be produced by modulating the coupling strength between the planar PWG mode provided by h-BN nanosheets and the surface plasmon polariton (SPP) mode in the silver film–silicon hybrid nanostructure. Compared with conventional phase-modulation SPR biosensors, our proposed configuration based on Fano resonance can produce ultrahigh reflectivity of 0.934 and overcome the limitation of quasi-darkness reflectivity which is difficult for further phase extraction. More importantly, our proposed FR configuration can provide a promising phase detection sensitivity as high as 3.13 × 106 degree per RIU (refractive index unit, RIU), which is enhanced by almost 100 times compared with conventional phase-modulation SPR biosensors. In addition, our proposed configuration has also shown the characteristics of multiple-order Fano resonances, largely depending on the partial coupling between the SPP mode and the different-order PWG mode. Our proposed FR biosensor can provide a highly promising candidate for designing a multiple-order FR platform for performing ultrasensitive detection.

15 December 2022 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
ZLZhen Lu
Zhen Lu
SWSihan Wu
Sihan Wu
ZXZeyu Xiao
Zeyu Xiao
JSJun Song
Jun Song
HWHuifeng Wu
Huifeng Wu
XPXiao Peng
Xiao Peng
Polystyrene nanoplastics (PS-NPs) are typical accumulated nanoplastics in the marine environment and organisms, and have strong potential risks to marine ecological environment and human health. MiRNAs could respond to and participate in the response process of environmental stressors. However, the response of miRNAs to nanoplastics has not been fully explored. In this study, miRNA responses of digestive glands in mussels Mytilus galloprovincialis treated by 200 nm PS-NPs (20, 200, 2000 μg/L) for 7 days were characterized by BGISEQ-500 deep sequencing and bioinformatics analysis, along with histopathological quantification with planimetric parameters on hematoxylin and eosin (H&E) staining. Results showed that one novel miRNA (novel_mir63) and seven known miRNAs (miR-34_2, miR-34_5, miR-281_8, let-7-5p_6, miR-10, miR-124, miR-29b-3p) were significantly (adjusted P-value < 0.05) differentially expressed after PS-NPs treatments, and most of them were down-regulated expect for novel_mir63 and miR-34_2. Function analysis of target genes corresponding to these differentially expressed miRNAs indicated that PS-NPs disturbed the process related to metabolism, aging, cardiac function, neural excitation, and repairment. Among them, acetyl-CoA C-acetyltransferase and purine metabolism pathway played vital connection roles. Meanwhile, significantly morphology changes of digestive tubes obtained from H&E stained sections also implied severely disrupted metabolic capability in digestive glands, reflected by significantly increased mean diverticular radius (MDR) and mean luminal radius (MLR) values and the ratio of MLR to mean epithelial thickness (MET), and significantly decreased MET value and MET/MDR. Overall, these findings have revealed new characterization of miRNAs and their target genes in mussel M. galloprovincialis under PS-NPs stress, and provide important clues to further elucidate the toxicity mechanisms of PS-NPs.

11 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KLKeyi Li
Keyi Li
LLLintong Li
Lintong Li
NXNanlin Xu
Nanlin Xu
XPXiao Peng
Xiao Peng
YZYingxin Zhou
Yingxin Zhou
Junle QuJunle Qu
Junle Qu
This study theoretically proposed a novel surface plasmon resonance biosensor by incorporating emerging two dimensional material blue phosphorus and graphene layers with plasmonic gold film. The excellent performances employed for biosensing can be realized by accurately tuning the thickness of gold film and the number of blue phosphorus interlayer. Our proposed plasmonic biosensor architecture designed by phase modulation is much superior to angular modulation, providing 4 orders of magnitude sensitivity enhancement. In addition, the optimized stacked configuration is 42 nm Au film/2-layer blue phosphorus /4-layer graphene, which can produce the sharpest differential phase of 176.7661 degrees and darkest minimum reflectivity as low as 5.3787 × 10−6. For a tiny variation in local refractive index of 0.0012 RIU (RIU, refractive index unit) due to the binding interactions of aromatic biomolecules, our proposed biosensor can provide an ultrahigh detection sensitivity up to 1.4731 × 105 °/RIU, highly promising for performing ultrasensitive biosensing application.

20 April 2021 in Frontiers in Chemistry
Verified
Journal Article
Open access
PDF file
YLYanfeng Liu
Yanfeng Liu
ZPZheng Peng
Zheng Peng
XPXiao Peng
Xiao Peng
WYWei Yan
Wei Yan
ZYZhigang Yang
Zhigang Yang
JQJunle Qu
Junle Qu
First reported in 1994, stimulated emission depletion (STED) microscopy has long been regarded as a powerful tool for real-time superresolved bioimaging . However, high STED light power (101∼3 MW/cm2) is often required to achieve significant resolution improvement, which inevitably introduces phototoxicity and severe photobleaching, damaging the imaging quality, especially for long-term cases. Recently, the employment of nanoprobes (quantum dots, upconversion nanoparticles, carbon dots, polymer dots, AIE dots, etc.) in STED imaging has brought opportunities to overcoming such long-existing issues. These nanomaterials designed for STED imaging show not only lower STED power requirements but also more efficient photoluminescence (PL) and enhanced photostability than organic molecular probes. Herein, we review the recent progress in the development of nanoprobes for STED imaging, to highlight their potential in improving the long-term imaging quality of STED microscopy and broadening its application scope. We also discuss the pros and cons for specific classes of nanoprobes for STED bioimaging in detail to provide practical references for biological researchers seeking suitable imaging kits, promoting the development of relative research field.

26 May 2021 in Membranes
Verified
Journal Article
Open access
PDF file
YGYong Guo
Yong Guo
YHYangrui Huang
Yangrui Huang
LJli jin
li jin
LWLuwei Wang
Luwei Wang
Zhigang YangZhigang Yang
Zhigang Yang
Junle QuJunle Qu
Junle Qu
We report a deep penetration microscopic imaging method with a non-diffracting Airy beam. The direct mapping of volume imaging in free space shows that the axial imaging range of the Airy beam is approximately 4 times that of the traditional Gaussian beam along the axial direction while maintaining a narrow lateral width. Benefiting from its non-diffracting property, the microscopic imaging with Airy beam illumination can acquire image structures through turbid medium and capture a volumetric image in a single frame. We demonstrate the penetration ability of the Airy microscopic imaging through a strongly scattering environment with 633 nm and 780 nm lasers. The performances of the volumetric imaging method were evaluated using HeLa cells and isolated mouse kidney tissue. The thick sample was scanned layer by layer in the Gaussian mode, however, in the Airy mode, the three-dimensional (3D) structure information was projected onto a two-dimensional (2D) image, which vastly increased the volume imaging speed. To show the characteristics of the Airy microscope, we performed dynamic volumetric imaging on the isolated mouse kidney tissue with two-photon.