Electret filters are electrostatically charged nonwovens which are commonly used in aerosol filtration to remove fine particles from gases. It is known that the charge and thus also the filtration efficiency can degrade over time. Thus, many testing standards require to remove the charge by treatment with liquid isopropanol (IPA) or IPA-saturated air. However, the parameters influencing this discharge have not been completely clarified yet. The aim of this work was, on the one hand, to experimentally investigate the influence of the IPA treatment on different electret filters and, on the other hand, to show the optimization potential of electret filters with respect to efficiency and long-term stability by numerical simulations. The experiments revealed that the air permeability is a central influencing parameter. Small pores lead to a reduced discharge efficiency using liquid IPA, while both treatment methods are suitable for larger pores. The simulations showed that a homogeneous charge distribution within the filter depth is advantageous for the initial performance. In contrast, charge penetrating deeper in the filter medium delays the charge decay and thus increases the operating time, with the trade-off of a lower initial performance.
The measurement and assessment of indoor air quality in terms of respirable particulate constituents is relevant, especially in light of the COVID-19 pandemic and associated infection events. To analyze indoor infectious potential and to develop customized hygiene concepts, the measurement monitoring of the anthropogenic aerosol spreading is necessary. For indoor aerosol measurements usually standard lab equipment is used. However, these devices are time-consuming, expensive and unwieldy. The idea is to replace this standard laboratory equipment with low-cost sensors widely used for monitoring fine dust (particulate matter—PM). Due to the low acquisition costs, many sensors can be used to determine the aerosol load, even in large rooms. Thus, the aim of this work is to verify the measurement capability of low-cost sensors. For this purpose, two different models of low-cost sensors are compared with established laboratory measuring instruments. The study was performed with artificially prepared NaCl aerosols with a well-defined size and morphology. In addition, the influence of the relative humidity, which can vary significantly indoors, on the measurement capability of the low-cost sensors is investigated. For this purpose, a heating stage was developed and tested. The results show a discrepancy in measurement capability between low-cost sensors and laboratory measuring instruments. This difference can be attributed to the partially different measuring method, as well as the different measuring particle size ranges. The determined measurement accuracy is nevertheless good, considering the compactness and the acquisition price of the low-cost sensors.