Jun Guo

Dr. Jun Guo


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Journal of Hydrology
Verified
Journal Article
Closed access
JGJun Guo
Jun Guo
YLYi Liu
Yi Liu
QZQiang Zou
Qiang Zou
Lei YeLei Ye
Lei Ye
SZShuang Zhu
Shuang Zhu
HZHairong Zhang
Hairong Zhang

19 April 2024 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
XCXinyu Chang
Xinyu Chang
JGJun Guo
Jun Guo
HQHui Qin
Hui Qin
JHJingwei Huang
Jingwei Huang
XWXinying Wang
Xinying Wang
PRPingan Ren
Pingan Ren

29 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
JLJiazheng Lu
Jiazheng Lu
JGJun Guo
Jun Guo
ZJZhou Jian
Zhou Jian
YYYihao Yang
Yihao Yang
WTWenhu Tang
Wenhu Tang
Ice disasters have frequently occurred worldwide in recent years, which seriously affected power transmission system operations. To improve the resilience of power grids and minimize economic losses, this paper proposes a framework for assessing the influence of ice disasters on the resilience of power transmission systems. This method considers the spatial–temporal impact of ice disasters on the resilience of power transmission systems, and the contingence set for risk assessment is established according to contingency probabilities. Based on meteorological data, the outage models of power transmission components are developed in the form of generic fragility curves, and the ice load is given by a simplified freezing rain ice model. A cell partition method is adopted to analyze the way ice disasters affect the operation of power transmission systems. The sequential Monte Carlo simulation method is used to assess resilience for capturing the stochastic impact of ice disasters and deriving the contingency set. Finally, the IEEE RTS-79 system is employed to investigate the impact of ice disasters by two case studies, which demonstrate the viability and effectiveness of the proposed framework. In turn, the results help recognize the resilience of the system under such disasters and the effects of different resilience enhancement measures.

1 January 2018 in IEEE Access
Verified
Journal Article
Open access
JLJiazheng Lu
Jiazheng Lu
JGJun Guo
Jun Guo
ZJZhou Jian
Zhou Jian
XXXunjian Xu
Xunjian Xu
Widespread fire disasters always occur in several concentrated short periods. A large range of fire disasters can cause the tripping of dozens of transmission lines simultaneously, posing a serious threat to safe operation of the power grid. The degree of risk cannot be efficiently calculated, making it difficult to guide the optimization of the allocation of fire extinguishing equipment. This paper describes the development of a large wildfire disaster power grid fault fire extinguishing equipment optimal allocation method and a proposed fast calculation method of transmission line risk. The risk index is calculated for different regional power grids according to subareas. According to the grid risk, fire extinguishing equipment will be deployed in advance to address high-risk areas of the grid fire, fully exploiting the limited equipment fire extinguishing effectiveness. The proposed method is verified in the Hunan provincial power grid as a case study. The results show that the number of calculations can be reduced to 1.2 × 10 3 for the case in which 20 transmission lines are threatened by fire disasters; using computer resources with 30 trillion operations per second, the calculation time is less than 5 min. This capability can provide scientific and efficient guidance for disaster treatment of the electric power grid.

17 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
JGJun Guo
Jun Guo
TFTao Feng
Tao Feng
ZCZelin Cai
Zelin Cai
XLXianglong Lian
Xianglong Lian
WTWenhu Tang
Wenhu Tang
The analysis of the fault propagation path of transmission lines and the method of identification of vulnerable lines during typhoon weather conditions is of great significance. In this context, this paper introduces the failure probability model of transmission lines under such conditions by considering both wind speed and the load of the lines. The Monte Carlo simulation (MCS) and the DC model based on OPA are applied to simulate the failure of transmission lines. The cascading failure state transition diagram (CFSTD) is proposed based on the failure chains and the criticality ranking of nodes in CFSTD by the average weight coefficient (AWC) for identifying vulnerable lines of the power grid under such conditions. A new weight in CFSTD is proposed to describe the vulnerability of each line and a new resilience index is used to assess the impacts of a typhoon on the system. The proposed method is demonstrated by using the modified IEEE 118-bus test system. Results show that the method proposed in this paper can simulate the fault propagation path, and identify the critical components of power grid under a typhoon.

17 November 2016 in Natural Hazards
Verified
Journal Article
Closed access
PDF file
JLJiazheng Lu
Jiazheng Lu
JGJun Guo
Jun Guo
JHJianping Hu
Jianping Hu
LYLi Yang
Li Yang
TFTao Feng
Tao Feng