Yanjun Wang

Dr. Yanjun Wang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
YCYan Chen
Yan Chen
YZYing Zhao
Ying Zhao
YWYanjun Wang
Yanjun Wang
Background: Diabetes is a complex metabolic disorder known to induce a high blood glucose level that fluctuates outside the normal range. Diabetes affects and damages the organs in the body and causes heart issues, blindness and kidney failure. Continuous monitoring is mandatory to keep the blood glucose level within a healthy range. Materials and Methods: This research was focused on diagnosing diabetes mellitus on zeolite nanoparticle-polyethylene glycol complex-immobilized interdigitated electrode sensor (IDE) surfaces. Zeolite nanoparticles were extracted from the fly ash of a thermal power plant by alkaline extraction. The surface morphology of the synthesized nanoparticles was observed by field-emission scanning electron microscopy and transmission electron microscopy, and the presence of certain elements and the particle size were determined by energy-dispersive X-ray spectroscopy and particle size analysis, respectively. Results: The crystalline PEG-zeolite nanoparticles were synthesized with a size of 40± 10 nm according to high-resolution microscopy. A particle size analyzer revealed the sizes of the fly ash and PEG-zeolite particles as 60± 10 μm and 50± 10 nm, respectively. The IDE surface was evaluated for its ability to display antifouling properties and sense glucose levels on the abovementioned nanoparticle-modified surface. Glucose oxidase was probed on the PEG-zeolite-modified IDE surface, and glucose was detected. PEG zeolite performed well with excellent antifouling properties on the IDE sensor surface and improved the glucose detection limit to 0.03 mg/mL from 0.08 mg/mL, as determined by linear regressions [y = 5.365x - 6.803; R2 = 0.9035 (zeolite surface) and y = 5.498x + 5.914R2 = 0.9061 (PEG-zeolite surface)]. This enhancement was ∼ 3-fold, and sensitivities were found to be 0.03 and 0.06 mg/mL glucose for the PEG-zeolite- and zeolite-modified surfaces, respectively, showing a 2-fold difference. Conclusion: The excellent biocompatible surface modified by PEG zeolite exhibited high performance and is useful for medical diagnosis.

11 March 2020 in Phytotherapy Research
Verified
Journal Article
Closed access
PDF file
YCYan Chen
Yan Chen
YZYing Zhao
Ying Zhao
YWYanjun Wang
Yanjun Wang
ANAli Nazary‐Vannani
Ali Nazary‐Vannani
Cain ClarkCain Clark
Cain Clark
YZYong Zhang
Yong Zhang

15 June 2016 in Journal of Acupuncture and Tuina Science
Verified
Journal Article
Closed access
PDF file
LZLihua Zhang
Lihua Zhang
YZYan-Chun Zhang
Yan-Chun Zhang
YWYanjun Wang
Yanjun Wang
YHYi-Xu Han
Yi-Xu Han
PLPengpeng li
Pengpeng li