New results achieved with recently grown Hg2Cl2 and PbBr2 crystals are described. With an optimized crystal growth technique Hg2Cl2 crystals were grown that show a significantly reduced acoustic attenuation compared to prior crystals, from 13.4 to 8 dB/μs-GHz2. These crystals allow the development of Hg2Cl2 Bragg cells with time-bandwidth product figures in the 5100 to 6900 range, frequency operation as high as that for Te02, and resolution about 25% higher than TeO2 for similar crystal lengths. PbBr2 crystals were also grown that exhibit a large figure of merit (M2 550) with an attenuation coefficient of 12 dB/μs-GHz2. This material may be the choice for infrared devices where large diffraction efficiencies are needed.
Device-quality single crystals of mercurous bromide were grown by the physical vapor transport method. Crystals transmitted light wavelengths up to and did not show any absorption bands. Detailed x-ray Laue and x-ray diffraction studies were used to characterize and orient the crystals. Optical evaluation was performed by fabricating slabs of crystals. A design was developed to fabricate acousto-optic tunable filters with 10-deg off-axis orientation operating in the mid- and long-wavelength regions. An acousto-optic tunable filter (AOTF) was fabricated using a crystal with a 16-mm optical aperture for the 10-deg design. A theoretical tuning curve for a mercurous bromide crystal-based AOTF using this design was also computed for the first time. Experimentally measured data on frequency matching agreed well with the theoretical predictions, and the transducer thickness was suitable for filtering with the fabricated AOTF.
Orientation-patterned zinc selenide (OPZnSe) is a unique quasi-phase-matched nonlinear optical material for enabling frequency conversion from visible to long-wave infrared wavelengths. We have fabricated and tested OPZnSe devices over a wide spectral range. Single-crystal OPZnSe films of greater than thickness were grown and characterized for optical loss showing an attenuation coefficient less than from . We demonstrated nonlinear frequency conversion in the near infrared, mid-infrared, and long-wave infrared in these devices through a variety of nonlinear optical mixing processes.
13 February 2019 in Crystal Research and Technology
Chromium- and cobalt-doped zinc selenide nanoparticles were synthesized using a low-temperature reactive solution growth method. The morphological and optical characteristics were compared to those of doped zinc selenide (ZnSe) bulk crystals grown by the physical vapor transport (PVT) method. We observed agglomeration of particles; however, the thioglycerol capping agent has been shown to limit particle grain growth and agglomeration. This process enables doping by addition of chromium and cobalt salts in the solution. A slightly longer refluxing time was required to achieve cobalt doping as compared with chromium doping due to lower refluxing temperature. The nanoparticle growth process showed an average particle size of approximately 300 nm for both Cr- and Co-doped zinc selenide. The optical characterization of Co:ZnSe is ongoing; however, preliminary results showed a very high bandgap compared to that of pure ZnSe bulk crystal. Additionally, Co:ZnSe has an order of magnitude higher fluorescence intensity compared to bulk Cr:ZnSe samples.
We have experimentally demonstrated and report on the results of crystal growth, fabrication, design, development, and performance for the long-wavelength infrared (LWIR) hyperspectral imager based on an acousto-optic tunable filter (AOTF) utilizing an efficient crystal, thallium arsenic selenide ( TAS). Results on the growth of -diameter, -long crystal boules, to fabricate -long AOTF devices, and on the system design and performance are presented. To achieve an -resolution AOTF, we developed a design utilizing growth at off from the axis of the crystal and achieved efficiency. A system concept was developed with high efficiency, resolution, and throughput utilizing this TAS AOTF. The test setup consisted of an LWIR camera (microbolometer), the AOTF, and a blackbody radiative source (hot filament), and represents the first time AOTF imaging has been achieved with a microbolometer camera. The filament was placed in front of the AOTF, and the camera was aligned to the first-order diffracted beam of the AOTF. The AOTF was tuned to wavelength by applying a rf signal to the transducer. Preliminary experimental results obtained for gas utilizing this system are reported.