Background: Proton arc therapy may improve physical dose conformity and reduce concerns of elevated linear energy transfer (LET) and relative biological effectiveness (RBE) at the end of the proton range, while offering more degrees of freedom for normal tissue sparing. To explore the potential of proton arc therapy, we studied the effect of increasing the number of beams on physical and biologically equivalent dose conformity in the setting of pediatric brain tumors. Material and methods: A cylindrical phantom (Ø = 150 mm) with central cylindrical targets (Ø = 25 and 30 mm) was planned with increasing number of equiangular coplanar proton beams (from 3 to 36). For four anonymized pediatric brain tumor patients, two ‘surrogate’ proton arc plans (18 equiangular coplanar or sagittal beams) and a reference plan with 3 non-coplanar beams were constructed. Biologically equivalent doses were calculated using two RBE scenarios: RBE1.1; and RBELET, the physical dose weighted by the LET. For both RBE scenarios, dose gradients were assessed, and doses to cognitive brain structures were reported. Results: Increasing the number of beams resulted in an improved dose gradient and reduced volume exposed to intermediate LET levels, at the expense of increased low-dose and low-LET volumes. Most of the differences between the two RBE scenarios were seen around the prescription dose level, where the isodose volumes increased with the RBELET plans, e.g. up to 63% in the 3-beam plan for the smallest phantom target. Overall, the temporal lobes were better spared with the sagittal proton arc surrogate plans, e.g. a mean dose of 3.9 Gy compared to 6 Gy in the reference 3-beam plan (median value, RBE1.1). Conclusion: Proton arc therapy has the potential to improve dose gradients to better spare cognitive brain structures. However, this is at the expense of increased low-dose/low-LET volumes, with possible implications for secondary cancer risks.
Background: Several brain substructures associated with cognition (BSCs) are located close to typical pediatric brain tumors. Pediatric patients therefore have considerable risks of neurocognitive impairment after brain radiotherapy. In this study, we investigated the radiation doses received by BSCs for three common locations of pediatric brain tumor entities. Material and methods: For ten patients in each group [posterior fossa ependymoma (PFE), craniopharyngioma (CP), and hemispheric ependymoma (HE)], the cumulative fraction of BSCs volumes receiving various dose levels were analyzed. We subsequently explored the differences in dose pattern between the three groups and used available dose response models from the literature to estimate treatment-induced intelligence quotient (IQ) decline. Results: Doses to BSCs were found to differ considerably between the groups, depending on their position relative to the tumor. Large inter-patient variations were observed in the ipsilateral structures of the HE groups, and at low doses for all three groups. IQ decline estimates differed depending on the model applied, presenting larger variations in the HE group. Conclusion: While there were notable differences in the dose patterns between the groups, the extent of estimated IQ decline depended more on the model applied. This inter-model variability should be considered in dose–effect assessments on cognitive outcomes of pediatric patients.
10 August 2023 in Physics and Imaging in Radiation Oncology
Proton arc therapy (PAT) is currently explored for clinical implementation, despite its associated low-dose bath. This study therefore aimed at evaluating the risk of radiation-induced second primary cancer (SPC) for PAT in pediatric brain tumor patients. Two brain-specific models for SPC induction were applied in five cases to compare volumetric modulated arc therapy (VMAT), intensity modulated proton therapy (IMPT) and PAT surrogate plans. The PAT integral dose was reduced by a median of 29% compared to VMAT, and 17% compared to IMPT. For both models, the estimated SPC risks were consistently the lowest for PAT.
Survivors of pediatric brain tumors are susceptible to neurovascular disease after radiotherapy, with dose to the chiasm or Circle of Willis (CW) as risk factors. The aims of this study were to dev...
As no guidelines for pencil beam scanning (PBS) proton therapy (PT) of paediatric posterior fossa (PF) tumours exist to date, this study investigated planning techniques across European PT centres, with special considerations for brainstem and spinal cord sparing. A survey and a treatment planning comparison were initiated across nineteen European PBS-PT centres treating paediatric patients. The survey assessed all aspects of the treatment chain, including but not limited to delineations, dose constraints and treatment planning. Each centre planned two PF tumour cases for focal irradiation, according to their own clinical practice but based on common delineations. The prescription dose was 54 Gy(RBE) for Case 1 and 59.4 Gy(RBE) for Case 2. For both cases, planning strategies and relevant dose metrics were compared. Seventeen (89 %) centres answered the survey, and sixteen (80 %) participated in the treatment planning comparison. In the survey, thirteen (68 %) centres reported using the European Particle Therapy Network definition for brainstem delineation. In the treatment planning study, while most centres used three beam directions, their configurations varied widely across centres. Large variations were also seen in brainstem doses, with a brainstem near maximum dose (D2%) ranging from 52.7 Gy(RBE) to 55.7 Gy(RBE) (Case 1), and from 56.8 Gy(RBE) to 60.9 Gy(RBE) (Case 2). This study assessed the European PBS-PT planning of paediatric PF tumours. Agreement was achieved in e.g. delineation-practice, while wider variations were observed in planning approach and consequently dose to organs at risk. Collaboration between centres is still ongoing, striving towards common guidelines.