Carlo Augusto Mallio

Dr. Carlo Augusto Mallio

Departmental Faculty of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Investigative Radiology
Verified
Journal Article
Closed access
YEYuri Errante
Yuri Errante
VCVincenzo Cirimele
Vincenzo Cirimele
Carlo Augusto MallioCarlo Augusto Mallio
Carlo Augusto Mallio
VLVincenzo Di Lazzaro
Vincenzo Di Lazzaro
Bruno Beomonte ZobelBruno Beomonte Zobel
Bruno Beomonte Zobel
CQCarlo Cosimo Quattrocchi
Carlo Cosimo Quattrocchi
The purpose of this study was to assess the association between the serial number of gadolinium-enhanced magnetic resonance imaging (MRI) examinations and the signal hyperintensity of the dentate nucleus on unenhanced T1-weighted images in patients with multiple sclerosis (MS) and those with brain metastases (BMs). A group of 38 patients with MS and 37 patients with BM who had undergone at least 2 consecutive enhanced MRI examinations in our institution were examined for this retrospective observational study. The average T1 signal intensity of the dentate nuclei and the pons was obtained, and the dentate nuclei-to-pons (DNP) signal intensity ratio was calculated. These values were compared between patients with less than 6 and 6 enhanced MRI scans or more (eMRI). Relative changes of the DNP were plotted against the number of enhanced MRI scans (eMRIn). A progressive increase in the T1 signal intensity of the DNP ratio was observed both in the MS group and in the BM group. The DNP ratios of the last eMRI scans in the subgroup of patients with 6 eMRI scans or more were significantly higher than those of the first eMRI scan in the MS group (P < 0.001) and in the BM group (P < 0.01). Relative changes of the DNP showed a positive correlation with the eMRIn with a Spearman ρ of 0.96 (P < 0.001) in the MS group and that of 0.88 (P < 0.001) in the BM group. Curve regression analyses of the relative change of DNP ratios showed linear models to best fit the data with r(2) of 0.89 in the MS group and r(2) of 0.74 in the BM group. Our study shows that the increase in the unenhanced T1 signal intensity has a linear relationship with the eMRIn in patients with MS and BM. Indeed, we estimated a linear regression model to fit the progressive increase in T1 signal intensity of the dentate nucleus after multiple enhanced MRI scans. This finding suggests substantial dechelation of gadodiamide in patients with normal renal function, raising further concerns regarding the stability of this agent. Further comparative studies with other gadolinium chelates, specifically both linear and macrocyclic, are strongly recommended.

1 July 2015 in Investigative Radiology
Verified
Journal Article
Closed access
CQCarlo Cosimo Quattrocchi
Carlo Cosimo Quattrocchi
Carlo Augusto MallioCarlo Augusto Mallio
Carlo Augusto Mallio
YEYuri Errante
Yuri Errante
VCVincenzo Cirimele
Vincenzo Cirimele
LCLuciano Carideo
Luciano Carideo
Bruno Beomonte ZobelBruno Beomonte Zobel
Bruno Beomonte Zobel
The dentate nucleus of the cerebellum may appear as hyperintense on unenhanced T1 magnetic resonance images (MRIs) of the brain. Recently, T1 signal hyperintensity has received attention owing to data on the association of this finding with the history of multiple injections of gadolinium-based contrast agents, specifically gadodiamide, in patients with multiple sclerosis and brain metastases. We conducted a retrospective study on patients with a meningioma who had routinely undergone follow-up enhanced MRI scans with gadodiamide. Across a time interval of 18 months (from January 2013 to July 2014), we identified 102 consecutive patients eligible for this study. A significant increase in T1 hyperintensity of the dentate nuclei of the cerebellum on nonenhanced scans was observed between the first and the last MRI in the group of patients with a history of at least 6 enhanced MRI scans (P < 0.01), whereas no differences were observed in the group with 1 to 5 enhanced MRI scans (P = 0.74). Further research is necessary to shed light on the mechanism of the T1 hyperintensity as well as on the histological and microstructural appearance of the dentate nucleus after multiple intravenous injections of gadodiamide. The finding raises the question of substantial dechelation of this agent in patients with normal renal function.

29 May 2023 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
Carlo Augusto MallioCarlo Augusto Mallio
Carlo Augusto Mallio
ASAndrea C. Sertorio
Andrea C. Sertorio
CBCaterina Bernetti
Caterina Bernetti
BZBruno Beomonte Zobel
Bruno Beomonte Zobel

18 July 2012 in Journal of Neuro-Oncology
Verified
Journal Article
Closed access
PDF file
CQCarlo Cosimo Quattrocchi
Carlo Cosimo Quattrocchi
YEYuri Errante
Yuri Errante
CGChiara Gaudino
Chiara Gaudino
Carlo Augusto MallioCarlo Augusto Mallio
Carlo Augusto Mallio
AGAlessandro Giona
Alessandro Giona
Bruno Beomonte ZobelBruno Beomonte Zobel
Bruno Beomonte Zobel

2 March 2013 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
CQCarlo Cosimo Quattrocchi
Carlo Cosimo Quattrocchi
AGAlessandro Giona
Alessandro Giona
Alberto Di MartinoAlberto Di Martino
Alberto Di Martino
YEYuri Errante
Yuri Errante
LSLaura Scarciolla
Laura Scarciolla
Bruno Beomonte ZobelBruno Beomonte Zobel
Bruno Beomonte Zobel
Objective To determine the prevalence of clinically and non-clinically relevant extra-spinal incidental findings (IF) in patients undergoing magnetic resonance imaging (MRI) of the lumbar spine and to evaluate the rate of undetected findings in archived radiological reports. Methods A retrospective search of patients undergoing lumbar spine MRI from January 2006 to December 2010 was conducted. By means of randomisation, we retrospectively reviewed 3,000 lumbar spine MRI examinations. Extra-spinal abnormalities were classified according to a modified CT Colonography Reporting and Data System (C-RADS). We retrospectively compared our structured approach with the archived MRI reports as it regarded the detection of extra-spinal IF to estimate non-detection rates. Results By means of the structured approach used, extra-spinal findings were detected in 2,060 (68.6 %) of the 3,000 lumbar spine MRI examinations; 362 (17.6 %) patients had indeterminate or clinically important findings (E3 and E4) requiring clinical correlation or further evaluation. After review of the original archived radiological reports, potentially important C-RADS E3 and E4 extra-spinal IF were respectively reported in 47 of the 265 (17.7 %) and in 8 of 74 (10.8 %) patients. Conclusions Our study shows that incidental extra-spinal findings at conventional lumbar spine MRI are common but underestimated in radiological reports.

7 October 2023 in European Radiology
Verified
Journal Article
Open access
PDF file
VMvan der Molen
van der Molen
AJAart J.
Aart J.
CQCarlo Cosimo Quattrocchi
Carlo Cosimo Quattrocchi
Carlo Augusto MallioCarlo Augusto Mallio
Carlo Augusto Mallio
IDIlona Dekkers
Ilona Dekkers
In 2014, for the first time, visible hyperintensities on unenhanced T1-weighted images in the nucleus dentatus and globus pallidus of the brain were associated with previous Gadolinium-based contrast agent (GBCA) injections and gadolinium deposition in patients with normal renal function. This led to a frenzy of retrospective studies with varying methodologies that the European Society of Magnetic Resonance in Medicine and Biology Gadolinium Research and Educational Committee (ESMRMB-GREC) summarised in 2019. Now, after 10 years, the members of the ESMRMB-GREC look backward and forward and review the current state of knowledge of gadolinium retention and deposition. Clinical relevance statement: Gadolinium deposition is associated with the use of linear GBCA but no clinical symptoms have been associated with gadolinium deposition. Key Points: • Traces of Gadolinium-based contrast agent-derived gadolinium can be retained in multiple organs for a prolonged time. • Gadolinium deposition is associated with the use of linear Gadolinium-based contrast agents. • No clinical symptoms have been associated with gadolinium deposition.