Aim: The objective of this study is to report the incidence of retinopathy of prematurity (ROP) outliers that fall outside the screening guidelines of the American Academy of Ophthalmology (AAO) in our country. Methods: A retrospective review of 503 records of newborns evaluated in our institution between January 2011 and March 2017. We analyzed the data by subgroups based on gestational age (GA), birth weight (BW) and stage, focusing on the outliers that don’t meet the criteria of the screening AAO guidelines (GA ≤ 30 weeks, BW ≤ 1500 g). Results: Of the 503 records, 352 had some degree of ROP, 91.76% being bilateral, and 26.2% require treatment. The mean GA at delivery was 30.56 ± 2.33 weeks, and the mean BW was 1287.90 ± 338.52 g. For the current AAO/AAP ROP screening, 19.9% were outliers, of which (57%) had ROP diagnosis and (38%) required treatment. Conclusions: ROP diagnosis in newborns of BW > 1500 g or GA > 30 weeks is not uncommon in Mexico, and it is important to take this into account to adjust the selection criteria on each population to reach all the infants at risk.
This paper proposes a teleophthalmology support system in which we use algorithms of object detection and semantic segmentation, such as faster region-based CNN (FR-CNN) and SegNet, based on several CNN architectures such as: Vgg16, MobileNet, AlexNet, etc. These are used to segment and analyze the principal anatomical elements, such as optic disc (OD), region of interest (ROI) composed by the macular region, real retinal region, and vessels. Unlike the conventional retinal image quality assessment system, the proposed system provides some possible reasons about the low-quality image to support the operator of an ophthalmoscope and patient to acquire and transmit a better-quality image to central eye hospital for its diagnosis. The proposed system consists of four steps: OD detection, OD quality analysis, obstruction detection of the region of interest (ROI), and vessel segmentation. For the OD detection, artefacts and vessel segmentation, the FR-CNN and SegNet are used, while for the OD quality analysis, we use transfer learning. The proposed system provides accuracies of 0.93 for the OD detection, 0.86 for OD image quality, 1.0 for artefact detection, and 0.98 for vessel segmentation. As the global performance metric, the kappa-based agreement score between ophthalmologist and the proposed system is calculated, which is higher than the score between ophthalmologist and general practitioner.
1 May 2019 in Translational Vision Science & Technology
Purpose: We describe the functioning of a novel device, aimed to assess patient head position after a pneumatic retinopexy. Methods: We enrolled patients with the clinical diagnosis of rhegmatogenous retinal detachment. All patients were asked to wear a specially designed headband with a monitoring device composed of an accelerometer, gyroscope, and magnetometer, powered by a 3.7V lithium battery. Every 200 ms, the device measured neck flexion and extension, left and right rotation, and left and right flexion. Patients were asked to come back the next morning for follow-up and headband retrieving. Results: The device was worn an average of 19.17 ± 2.1 hours and performed a mean number of 57,670 ± 8663 measurements without power failures or program errors. An acceptable head position was kept for a mean of 3.33 ± 1.8 hours. The hardest axis to maintain was the right and left flexion of the neck (5.5 ± 2.54 hours of acceptable positioning). Conclusion: Real-time monitoring of patient head position after a vitreoretinal procedure is feasible. Maintaining a fixed head position for more than 5 consecutive hours is difficult to achieve and physicians should consider this difficulty when planning treatment. Translational Relevance: In addition to a significant improvement to the basic design of similar devices, our device allows for assessment of patient adherence to postoperative instructions objectively for the first time to our knowledge. This information could be used in the future to elaborate more detailed position nomograms to improve outcomes
To describe fundus autofluorescence (FAF) patterns in premature infants and to determine whether FAF increases gradually with increasing post-gestational age. This was a cross-sectional, observational and descriptive case series. FAF images were obtained from patients screened for Retinopathy of Prematurity. The presence of the following hypo-autofluorescence areas/structures was graded and ranked: macular pigment (foveal centre), optic nerve head, peripapillary vessels/vascular arcade (PP/VA), and equatorial vessels (EqV). Ranks were attributed to the number of structures visualized from the posterior pole towards the periphery. The rank of FAF could then be analysed by Spearman’s correlation against age. Additionally, patients were divided by age into group 1 (< 40 weeks of corrected gestational age (WCGA)) and group 2 (> 40 WCGA). Differences between groups were tested with the Mann–Whitney U test. Thirteen patients were analysed. The mean WCGA at examination was 47.85 weeks. Spearman’s correlation showed a strong positive correlation (r = 0.714) (P = 0.006) of FAF and WCGA. The Mann–Whitney U test revealed that the PP/VA and EqV were significantly more visible at > 40 WCGA than at < 40 WCGA (8.0 [P = 0.016] and 7.5 [P = 0.03], respectively). Patterns of FAF are described for the first time in premature infants. FAF increases gradually with age and centrifugally from the posterior pole towards the equator in premature infants.
Uveal melanoma (UM) and conjunctival melanoma (CM) are distinct entities with different etiologies and genetic background. We present a case of an atypical subconjunctival melanoma arising from a b...