Dominik Krumm

Dr. Dominik Krumm

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CGCarina Gerlach
Carina Gerlach
DKDominik Krumm
Dominik Krumm
MIMarko Illing
Marko Illing
JLJustin Lange
Justin Lange
Olfa KanounOlfa Kanoun
Olfa Kanoun
AHArved Hubler
Arved Hubler
In this paper, a low cost and flexible plantar pressure monitoring system is presented that is suited for everyday use to prevent pressure ulcers. To define the technical specifications of the sensor system, a gait analysis study was carried out. Analysis of measured data based on a multivariate approach and neural network classification shows that it is possible to dissociate between healthy and unhealthy rollover patterns. To implement a pressure sensor element, a multiwalled carbon nanotube (MWCNT)-polydimethylsiloxane (PDMS)-composite was selected. A sensor matrix made of the composite was fully printed to enable pressure distribution measurements. As a final application, a printed insole was fabricated with six single MWCNT-PDMS pressure sensors that were situated on characteristic points of the insole to detect the unhealthy rollover patterns. Its functionality to measure plantar pressures was proven on a human foot inside a running shoe during walking.

1 July 2020 in Applied Ergonomics
Verified
Journal Article
Closed access
DKDominik Krumm
Dominik Krumm
SSStefan Schwanitz
Stefan Schwanitz
SOStephan Odenwald
Stephan Odenwald

27 July 2022 in Royal Society Open Science
Verified
Journal Article
Open access
MMMichael Mauersberger
Michael Mauersberger
FHFalk Hähnel
Falk Hähnel
KWKlaus Wolf
Klaus Wolf
JMJohannes Markmiller
Johannes Markmiller
AKAlexander Knorr
Alexander Knorr
SOStephan Odenwald
Stephan Odenwald
Aircraft design must be lightweight and cost-efficient on the condition of aircraft certification. In addition to standard load cases, human-induced loads can occur in the aircraft interior. These are crucial for optimal design but difficult to estimate. In this study, a simple bipedal spring-mass model with roller feet predicted human-induced loads caused by human gait for use within an end-to-end design process. The prediction needed no further experimental data. Gait movement and ground reaction force (GRF) were simulated by means of two parameter constraints with easily estimable input variables (gait speed, body mass, body height). To calibrate and validate the prediction model, experiments were conducted in which 12 test persons walked in an aircraft mock-up under different conditions. Additional statistical regression models helped to compensate for bipedal model limitations. Direct regression models predicted single GRF parameters as a reference without a bipedal model. The parameter constraint with equal gait speed in experiment and simulation yielded good estimates of force maxima (error 5.3%), while equal initial GRF gave a more reliable prediction. Both parameter constraints predicted contact time very well (error 0.9%). Predictions with the bipedal model including full GRF curves were overall as reliable as the reference.

9 December 2012 in Sports Engineering
Verified
Journal Article
Closed access
PDF file
DKDominik Krumm
Dominik Krumm
SSStefan Schwanitz
Stefan Schwanitz
SOStephan Odenwald
Stephan Odenwald

1 January 2014 in Procedia Engineering
Verified
Journal Article
Open access
SOStephan Odenwald
Stephan Odenwald
DKDominik Krumm
Dominik Krumm

21 March 2023 in Sports Engineering
Verified
Journal Article
Open access
PDF file
GSGiuseppe Sanseverino
Giuseppe Sanseverino
DKDominik Krumm
Dominik Krumm
WKWolfgang Kilian
Wolfgang Kilian
SOStephan Odenwald
Stephan Odenwald
The analysis of human gait is of fundamental importance for the monitoring and enhancement of athletes’ performances. The kinematics and kinetics of human gait are mostly investigated with optical motion capture systems and force plates that require specialised laboratories and limit the possible test conditions. On the contrary, body-attached sensor networks provide an opportunity for long-term acquisitions in unsupervised, naturalistic scenarios. In this study, a wearable sensor network consisting of two wireless dataloggers and two instrumented insoles with eight pressure sensors each is used. Custom algorithms for the automatic detection of hike events and the estimation of the related temporal parameters based on sensors data are presented. The proposed algorithms were tested against laboratory measurements performed on an instrumented treadmill and showed relative errors of less than 2.5% in the estimation of stride time, step time and cadence. Higher relative errors were found in the estimation of stance and swing phases. The developed algorithms were also applied in a field study. In this paper data from one subject are considered. The aim of this research work is to provide an effective sensor-based methodology for the evaluation of gait parameters in naturalistic settings.