Qiangsheng Li

Mr. Qiangsheng Li

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 January 2021 in Journal of Cleaner Production
Verified
Journal Article
Closed access
CXChen Xiong
Chen Xiong
QLQiangsheng Li
Qiangsheng Li
TLTianhao Lan
Tianhao Lan
HLHaodao Li
Haodao Li
WLWujian Long
Wujian Long
FXFeng Xing
Feng Xing

15 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
CXChen Xiong
Chen Xiong
TLtian hao Lan
tian hao Lan
QLQiangsheng Li
Qiangsheng Li
HLHao-Dao Li
Hao-Dao Li
WLWu-Jian Long
Wu-Jian Long
This study investigates the feasibility of collaborative use of recycled carbon fiber reinforced polymer (RCFRP) fibers and recycled aggregate (RA) in concrete, which is called RCFRP fiber reinforced RA concrete (RFRAC). The mechanical properties of the composite were studied through experimental investigation, considering different RCFRP fiber contents (0%, 0.5%, 1.0%, and 1.5% by volume) and different RA replacement rates (0%, 10%, 20%, and 30% by volume). Specifically, ten different mixes were designed to explore the flowability and compressive and flexural strengths of the proposed composite. Experimental results indicated that the addition of RCFRP fibers and RA had a relatively small influence on the compressive strength of concrete (less than 5%). Moreover, the addition of RA slightly decreased the flexural strength of concrete, while the addition of RCFRP fibers could significantly improve the flexural performance. For example, the flexural strength of RA concrete with 1.5% RCFRP fiber addition increased by 32.7%. Considering the good flexural properties of the composite and its potential in reducing waste CFRP and construction solid waste, the proposed RFRAC is promising for use in civil concrete structures with high flexural performance requirements.

7 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRuihao Zheng
Ruihao Zheng
CXChen Xiong
Chen Xiong
XDXiangbin Deng
Xiangbin Deng
QLQiangsheng Li
Qiangsheng Li
YLYi Li
Yi Li
This study presents a machine learning-based method for the destructive power assessment of earthquake to structures. First, the analysis procedure of the method is presented, and the backpropagation neural network (BPNN) and convolutional neural network (CNN) are used as the machine learning algorithms. Second, the optimized BPNN architecture is obtained by discussing the influence of a different number of hidden layers and nodes. Third, the CNN architecture is proposed based on several classical deep learning networks. To build the machine learning models, 50,570 time-history analysis results of a structural system subjected to different ground motions are used as training, validation, and test samples. The results of the BPNN indicate that the features extraction method based on the short-time Fourier transform (STFT) can well reflect the frequency-/time-domain characteristics of ground motions. The results of the CNN indicate that the CNN exhibits better accuracy (R2 = 0.8737) compared with that of the BPNN (R2 = 0.6784). Furthermore, the CNN model exhibits remarkable computational efficiency, the prediction of 1000 structures based on the CNN model takes 0.762 s, while 507.81 s are required for the conventional time-history analysis (THA)-based simulation. Feature visualization of different layers of the CNN reveals that the shallow to deep layers of the CNN can extract the high to low-frequency features of ground motions. The proposed method can assist in the fast prediction of engineering demand parameters of large-number structures, which facilitates the damage or loss assessments of regional structures for timely emergency response and disaster relief after earthquake.

14 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CXChen Xiong
Chen Xiong
XDXiangbin Deng
Xiangbin Deng
YLYanmei Liang
Yanmei Liang
QLQiangsheng Li
Qiangsheng Li
JHJin Huang
Jin Huang
DLDawang Li
Dawang Li
Buildings in coastal cities are susceptible to chloride ion attack and the seismic performance of these buildings can be impaired due to corrosion of reinforcements. In this study, a regional seismic damage simulation method that considers the influence of corrosion-induced seismic performance degradation is proposed. Firstly, the framework of the method is introduced, and the simulation process is presented. Secondly, experimental data of corroded reinforced concrete (RC) components are collected to obtain the reduction rules of component level backbone curve parameters (i.e., initial stiffness, peak carrying capacity, peak displacement, and ultimate carrying capacity). Afterwards, pushover analyses of typical RC frames in different corrosion conditions (i.e., degree of corrosion of components and proportion of corroded components) are conducted to acquire the reduction rules of interstory backbone curve parameters of corroded RC frame structures. Finally, RC frame structures, in Shenzhen city, are simulated using different corrosion scenarios. Simulated results indicate that some buildings along the coastline are affected by airborne chloride-induced corrosion and severe seismic damage can be observed. Moreover, some buildings that are far from the coastline can also experience severe seismic damage due to irregular use of sea sand as constructional material. The proposed method can be used to simulate the seismic performance of corroded RC structures and the outcomes of this study are expected to provide a useful reference for the seismic risk management of coastal cities.