Erik Reimhult

Erik Reimhult


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2008 in Sensors
Verified
Journal Article
Open access
PDF file
DGDorothee Grieshaber
Dorothee Grieshaber
RMRobert MacKenzie
Robert MacKenzie
JVJanos Voros
Janos Voros
ERErik Reimhult
Erik Reimhult
Quantification of biological or biochemical processes are of utmost importance for medical, biological and biotechnological applications. However, converting the biological information to an easily processed electronic signal is challenging due to the complexity of connecting an electronic device directly to a biological environment. Electrochemical biosensors provide an attractive means to analyze the content of a biological sample due to the direct conversion of a biological event to an electronic signal. Over the past decades several sensing concepts and related devices have been developed. In this review, the most common traditional techniques, such as cyclic voltammetry, chronoamperometry, chronopotentiometry, impedance spectroscopy, and various field-effect transistor based methods are presented along with selected promising novel approaches, such as nanowire or magnetic nanoparticle-based biosensing. Additional measurement techniques, which have been shown useful in combination with electrochemical detection, are also summarized, such as the electrochemical versions of surface plasmon resonance, optical waveguide lightmode spectroscopy, ellipsometry, quartz crystal microbalance, and scanning probe microscopy. The signal transduction and the general performance of electrochemical sensors are often determined by the surface architectures that connect the sensing element to the biological sample at the nanometer scale. The most common surface modification techniques, the various electrochemical transduction mechanisms, and the choice of the recognition receptor molecules all influence the ultimate sensitivity of the sensor. New nanotechnology-based approaches, such as the use of engineered ion-channels in lipid bilayers, the encapsulation of enzymes into vesicles, polymersomes, or polyelectrolyte capsules provide additional possibilities for signal amplification. In particular, this review highlights the importance of the precise control over the delicate interplay between surface nano-architectures, surface functionalization and the chosen sensor transducer principle, as well as the usefulness of complementary characterization tools to interpret and to optimize the sensor response.


16 October 2009 in Nano Letters
Verified
Journal Article
Closed access
EAEsther Amstad
Esther Amstad
TGTorben Gillich
Torben Gillich
IBIdalia Bilecka
Idalia Bilecka
MTMarcus Textor
Marcus Textor
ERErik Reimhult
Erik Reimhult

31 May 2011 in Nanoscale
Verified
Journal Article
Closed access
PDF file
EAEsther Amstad
Esther Amstad
MTMarcus Textor
Marcus Textor
ERErik Reimhult
Erik Reimhult
Superparamagnetic iron oxide nanoparticles (NPs) are used in a rapidly expanding number of research and practical applications in the biomedical field, including magnetic cell labeling separation and tracking, for therapeutic purposes in hyperthermia and drug delivery, and for diagnostic purposes, e.g., as contrast agents for magnetic resonance imaging. These applications require good NP stability at physiological conditions, close control over NP size and controlled surface presentation of functionalities. This review is focused on different aspects of the stability of superparamagnetic iron oxide NPs, from its practical definition to its implementation by molecular design of the dispersant shell around the iron oxide core and further on to its influence on the magnetic properties of the superparamagnetic iron oxide NPs. Special attention is given to the selection of molecular anchors for the dispersant shell, because of their importance to ensure colloidal and functional stability of sterically stabilized superparamagnetic iron oxide NPs. We further detail how dispersants have been optimized to gain close control over iron oxide NP stability, size and functionalities by independently considering the influences of anchors and the attached sterically repulsive polymer brushes. A critical evaluation of different strategies to stabilize and functionalize core–shell superparamagnetic iron oxide NPs as well as a brief introduction to characterization methods to compare those strategies is given.

25 February 2011 in Nano Letters
Verified
Journal Article
Closed access
EAEsther Amstad
Esther Amstad
JKJoachim Kohlbrecher
Joachim Kohlbrecher
EMElisabeth Müller
Elisabeth Müller
TSThomas Schweizer
Thomas Schweizer
MTMarcus Textor
Marcus Textor
ERErik Reimhult
Erik Reimhult

6 November 2004 in Analytical Chemistry
Verified
Journal Article
Closed access
ERErik Reimhult
Erik Reimhult
CLCharlotte Larsson
Charlotte Larsson
BKBengt Kasemo
Bengt Kasemo
FHFredrik Höök
Fredrik Höök