Fatigue is one of the main causes for in service failure of mechanical components and structures. With the development of new materials, such as high strength aluminium or titanium alloys with different microstructures from steels, materials no longer have a fatigue limit in the classical sense, where it was accepted that they would have ‘infinite life’ from 10 million (107) cycles. The emergence of new materials used in critical mechanical parts, including parts obtained from metal additive manufacturing (AM), the need for weight reduction and the ambition to travel greater distances in shorter periods of time, have brought many challenges to design engineers, since they demand predictability of material properties and that they are readily available. Most fatigue testing today still uses uniaxial loads. However, it is generally recognised that multiaxial stresses occur in many full-scale structures, being rare the occurrence of pure uniaxial stress states. By combining both Ultrasonic Fatigue Testing with multiaxial testing through Single-Input-Multiple-Output Modal Analysis, the high costs of both equipment and time to conduct experiments have seen a massive improvement. It is presently possible to test materials under multiaxial loading conditions and for a very high number of cycles in a fraction of the time compared to non-ultrasonic fatigue testing methods (days compared to months or years). This work presents the current status of ultrasonic fatigue testing machines working at a frequency of 20 kHz to date, with emphasis on multiaxial fatigue and very high cycle fatigue. Special attention will be put into the performance of multiaxial fatigue tests of classical cylindrical specimens under tension/torsion and flat cruciform specimens under in-plane bi-axial testing using low cost piezoelectric transducers. Together with the description of the testing machines and associated instrumentation, some experimental results of fatigue tests are presented in order to demonstrate how ultrasonic fatigue testing can be used to determine the behaviour of a steel alloy from a railway wheel at very high cycle fatigue regime when subjected to multiaxial tension/torsion loadings.
5 June 2025 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Vegetal fibre composites are in significant demand by the industry due to their renewability and biodegradability. An important characteristic of fibre reinforced composites is that various mechanical responses can be obtained by altering the constitutive stacking sequence of laminates. The bio-inspiration of the composite designs represents an increasing trend due to their capacity to improve the overall strength of the structure. In this study, samples with bioinspired and non-inspired, quasi-isotropic, stacking configurations were manufactured. Hand layup of flax fibre epoxy pre-preg, consolidation using vacuum bagging and polymerisation in autoclave were used as the manufacturing method. The test samples have been tested under a constant quasi static regime of 2 mm/min with three mechanical response regions being identified. Two samples from each stacking configuration have been tested and the mean mechanical response has been considered in the investigation. The contact force-displacement data, energy absorbed, maximum contact force and related displacement are reported. The bio-inspired stacking sequence
[±45/40/80]
s laminates showed with 62% higher peak load than the conventional stacking laminate. The main energy dissipating mechanisms, observed by looking at the front and rear of the samples, were matrix cracking, delamination and fibre failure. It can be detected, in terms that the quasi-isotropic stacking sequence exhibited a limited damage area compared to the bio-inspired samples.