Julián David Arias-Londoño

Prof. Julián David Arias-Londoño

Department of Systems Engineering and Computer Science, Universidad de Antioquia, Medellín, Antioquia, Colombia

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Juan Rafael Orozco-ArroyaveJuan Rafael Orozco-Arroyave
Juan Rafael Orozco-Arroyave
FHF. Hönig
F. Hönig
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
JVJ. F. Vargas-Bonilla
J. F. Vargas-Bonilla
KDK. Daqrouq
K. Daqrouq
ENE. Nöth
E. Nöth
The aim of this study is the analysis of continuous speech signals of people with Parkinson's disease (PD) considering recordings in different languages (Spanish, German, and Czech). A method for the characterization of the speech signals, based on the automatic segmentation of utterances into voiced and unvoiced frames, is addressed here. The energy content of the unvoiced sounds is modeled using 12 Mel-frequency cepstral coefficients and 25 bands scaled according to the Bark scale. Four speech tasks comprising isolated words, rapid repetition of the syllables /pa/-/ta/-/ka/, sentences, and read texts are evaluated. The method proves to be more accurate than classical approaches in the automatic classification of speech of people with PD and healthy controls. The accuracies range from 85% to 99% depending on the language and the speech task. Cross-language experiments are also performed confirming the robustness and generalization capability of the method, with accuracies ranging from 60% to 99%. This work comprises a step forward for the development of computer aided tools for the automatic assessment of dysarthric speech signals in multiple languages.

1 April 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
LMLaureano Moro-Velazquez
Laureano Moro-Velazquez
JGJorge A. Gomez-Garcia
Jorge A. Gomez-Garcia
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
NDNajim Dehak
Najim Dehak
JGJuan I. Godino-Llorente
Juan I. Godino-Llorente

1 November 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Juan Rafael Orozco-ArroyaveJuan Rafael Orozco-Arroyave
Juan Rafael Orozco-Arroyave
EBElkyn Alexander Belalcazar-Bolanos
Elkyn Alexander Belalcazar-Bolanos
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
JVJesus Francisco Vargas-Bonilla
Jesus Francisco Vargas-Bonilla
SSSabine Skodda
Sabine Skodda
ENElmar Noth
Elmar Noth
This paper evaluates the accuracy of different characterization methods for the automatic detection of multiple speech disorders. The speech impairments considered include dysphonia in people with Parkinson's disease (PD), dysphonia diagnosed in patients with different laryngeal pathologies (LP), and hypernasality in children with cleft lip and palate (CLP). Four different methods are applied to analyze the voice signals including noise content measures, spectral-cepstral modeling, nonlinear features, and measurements to quantify the stability of the fundamental frequency. These measures are tested in six databases: three with recordings of PD patients, two with patients with LP, and one with children with CLP. The abnormal vibration of the vocal folds observed in PD patients and in people with LP is modeled using the stability measures with accuracies ranging from 81% to 99% depending on the pathology. The spectral-cepstral features are used in this paper to model the voice spectrum with special emphasis around the first two formants. These measures exhibit accuracies ranging from 95% to 99% in the automatic detection of hypernasal voices, which confirms the presence of changes in the speech spectrum due to hypernasality. Noise measures suitably discriminate between dysphonic and healthy voices in both databases with speakers suffering from LP. The results obtained in this study suggest that it is not suitable to use every kind of features to model all of the voice pathologies; conversely, it is necessary to study the physiology of each impairment to choose the most appropriate set of features.

21 October 2010 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
JGJ I Godino-Llorente
J I Godino-Llorente
NSNicolás Sáenz-Lechón
Nicolás Sáenz-Lechón
VOVíctor Osma-Ruiz
Víctor Osma-Ruiz
GCGerman Castellanos-Dominguez
German Castellanos-Dominguez
This paper proposes a new approach to improve the amount of information extracted from the speech aiming to increase the accuracy of a system developed for the automatic detection of pathological voices. The paper addresses the discrimination capabilities of 11 features extracted using nonlinear analysis of time series. Two of these features are based on conventional nonlinear statistics (largest Lyapunov exponent and correlation dimension), two are based on recurrence and fractal-scaling analysis, and the remaining are based on different estimations of the entropy. Moreover, this paper uses a strategy based on combining classifiers for fusing the nonlinear analysis with the information provided by classic parameterization approaches found in the literature (noise parameters and mel-frequency cepstral coefficients). The classification was carried out in two steps using, first, a generative and, later, a discriminative approach. Combining both classifiers, the best accuracy obtained is 98.23% ± 0.001.

14 December 2020 in IEEE Access
Verified
Journal Article
Open access
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
JGJORGE ANDRÉS GÓMEZ GARCÍA
JORGE ANDRÉS GÓMEZ GARCÍA
LMLaureano Moro-Velazquez
Laureano Moro-Velazquez
JGJuan I. Godino-Llorente
Juan I. Godino-Llorente
Current standard protocols used in the clinic for diagnosing COVID-19 include molecular or antigen tests, generally complemented by a plain chest X-Ray. The combined analysis aims to reduce the significant number of false negatives of these tests and provide complementary evidence about the presence and severity of the disease. However, the procedure is not free of errors, and the interpretation of the chest X-Ray is only restricted to radiologists due to its complexity. With the long term goal to provide new evidence for the diagnosis, this paper presents an evaluation of different methods based on a deep neural network. These are the first steps to develop an automatic COVID-19 diagnosis tool using chest X-Ray images to differentiate between controls, pneumonia, or COVID-19 groups. The paper describes the process followed to train a Convolutional Neural Network with a dataset of more than 79, 500 X-Ray images compiled from different sources, including more than 8, 500 COVID-19 examples. Three different experiments following three preprocessing schemes are carried out to evaluate and compare the developed models. The aim is to evaluate how preprocessing the data affects the results and improves its explainability. Likewise, a critical analysis of different variability issues that might compromise the system and its effects is performed. With the employed methodology, a 91.5% classification accuracy is obtained, with an 87.4% average recall for the worst but most explainable experiment, which requires a previous automatic segmentation of the lung region.

12 November 2010 in Logopedics Phoniatrics Vocology
Verified
Journal Article
Closed access
Julián David Arias-LondoñoJulián David Arias-Londoño
Julián David Arias-Londoño
JGJuan I. Godino-Llorente
Juan I. Godino-Llorente
MMMaria Markaki
Maria Markaki
YSYannis Stylianou
Yannis Stylianou
This work presents a novel approach for the automatic detection of pathological voices based on fusing the information extracted by means of mel-frequency cepstral coefficients (MFCC) and features derived from the modulation spectra (MS). The system proposed uses a two-stepped classification scheme. First, the MFCC and MS features were used to feed two different and independent classifiers; and then the outputs of each classifier were used in a second classification stage. In order to establish the best configuration which provides the highest accuracy in the detection, the fusion of information was carried out employing different classifier combination strategies. The experiments were carried out using two different databases: the one developed by The Massachusetts Eye and Ear Infirmary Voice Laboratory, and a database recorded by the Universidad Politécnica de Madrid. The results show that the combination of MFCC and MS features employing the proposed approach yields an improvement in the detection accuracy, demonstrating that both methods of parameterization are complementary.