This paper reports the experience acquired with a photovoltaic (PV) hybrid system simulated as an alternative to diesel system for a residential home located in Southern Nigeria. The hybrid system was designed to overcome the problem of climate change, to ensure a reliable supply without interruption, and to improve the overall system efficiency (by the integration of the battery bank). The system design philosophy was to maximize simplicity; hence, the system was sized using conventional simulation tool and representative insolation data. The system includes a 15 kW PV array, 21.6 kWh (3600 Ah) worth of battery storage, and a 5.4 kW (6.8 kVA) generator. The paper features a detailed analysis of the energy flows through the system and quantifies all losses caused by PV charge controller, battery storage round-trip, rectifier, and inverter conversions. In addition, simulation was run to compare PV/diesel/battery with diesel/battery and the results show that the capital cost of a PV/diesel hybrid solution with batteries is nearly three times higher than that of a generator and battery combination, but the net present cost, representing cost over the lifetime of the system, is less than one-half of the generator and battery combination.
The objective of this work is to develop a power management system that will control the power flow of an integrated renewable energy system with the focus on solar energy and wind energy and dual energy storage systems (batteries are used as the primary energy storage system for short to moderate storage term, whereas hydrogen fuel cell is used as a backup and long-term energy storage). These storage systems are needed to provide high reliability and control systems are necessary for the stable and optimal operation of the whole system. An Intelligent Power Management System (IPMS) is developed to handle various changes in power supply and power demand by managing erratic power and provide suitable control algorithm for the whole system. In order to test and validate the proposed IPMS model, simulations were conducted under various power supply and power demand using power system modeled in HOMER environment. The performed simulations confirm the ability of the IPMS to satisfy the load at all times using solar and wind power (which are unsteady renewables), through the support of batteries and hydrogen fuel cell without a reduction in the power quality or load supply.
7 April 2021 in Renewable Energy and Environmental Sustainability
Primary Healthcare Centres (PHCs) remain the populations' first point of contact when seeking medical help. Women and children, whose health status decides the fate of the country, are the predominant users of primary healthcare centres which means they (the PHCs') must function as high quality health providers. Karshi Primary Healthcare Centre (KPHC) is one of the health facility that need reliable electricity to improve their healthcare delivery. Due to unreliable power supply, they rely on a diesel powered solution as a primary source of power supply. This negatively impacts patients and the environment, and has been a burden on their operational budgets. Change in energy system is the solution to this unreliable, costly, and unsecure power supply in Karshi, and its objective is to improve and enhance the quality of healthcare delivery services. The assumption is that with better energy source, there will be better healthcare services. A solar powered system with battery storage was proposed as the solution and the simulation results demonstrate that except for the initial cost of investment, the solar PV generator performs better than the diesel generator, in terms of the life cycle costs and the cost per unit energy. The life cycle cost and the cost of energy show a decrease of 75% each. The environmental analysis implies that the solar PV energy system has the potential to avoid the 9371 kg of carbon dioxide if the system is implemented in the future at KPHC. The proposed powered system will supply electricity for the laboratory equipment (centrifuges, microscopes, blood chemical analyzer, hematology analyzer, CD4 machine), vaccine-refrigeration, general purpose refrigerator, computer and telecommunications, while being able to cater to a greater number of patients than in the past.
Access to electricity can have a positive psychological impact through a lessening of the sense of exclusion, and vulnerability often felt by the orphanages. This paper presented the simulation and optimization study of a stand-alone photovoltaic power system that produced the desired power needs of an orphanage. Solar resources for the design of the system were obtained from the National Aeronautics and Space Administration (NASA) Surface Meteorology and Solar Energy website at a location of 6°51′N latitude and 7°35′E longitude, with annual average solar radiation of 4.92 kWh/m2/d. This study is based on modeling, simulation, and optimization of energy system in the orphanage. The patterns of load consumption within the orphanage were studied and suitably modeled for optimization. Hybrid Optimization Model for Electric Renewables (HOMER) software was used to analyze and design the proposed stand-alone photovoltaic power system model. The model was designed to provide an optimal system configuration based on an hour-by-hour data for energy availability and demands. A detailed design, description, and expected performance of the system were presented in this paper.
This paper presents the feasibility analysis and study of integrated renewable energy (IRE) using solar photovoltaic (PV) and wind turbine (WT) system in a hypothetical study of rural health clinic in Borno State, Nigeria. Electrical power consumption and metrology data (such as solar radiation and wind speed) were used for designing and analyzing the integrated renewable energy system. The health clinic facility energy consumption is 19 kWh/day with a 3.4 kW peak demand load. The metrological data was collected from National Aeronautics and Space Administration (NASA) website and used to analyze the performance of electrical generation system using HOMER program. The simulation and optimization results show that the optimal integrated renewable energy system configuration consists of 5 kW PV array, BWC Excel-R 7.5 kW DC wind turbine, 24 unit Surrette 6CS25P battery cycle charging, and a 19 kW AC/DC converter and that the PV power can generate electricity at 9,138 kWh/year while the wind turbine system can generate electricity at 7,490 kWh/year, giving the total electrical generation of the system as 16,628 kWh/year. This would be suitable for deployment of 100% clean energy for uninterruptable power performance in the health clinic. The economics analysis result found that the integrated renewable system has total NPC of 137,139 US Dollar. The results of this research show that, with a low energy health facility, it is possible to meet the entire annual energy demand of a health clinic solely through a stand-alone integrated renewable PV/wind energy supply.