Nadra Bohli

Dr. Nadra Bohli

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SBSyrine Behi
Syrine Behi
NBNadra Bohli
Nadra Bohli
JCJuan Casanova-Cháfer
Juan Casanova-Cháfer
Eduard LlobetEduard Llobet
Eduard Llobet
AAAbdelghani Adnane
Abdelghani Adnane
Benzene, toluene, and xylene, commonly known as BTX, are hazardous aromatic organic vapors with high toxicity towards living organisms. Many techniques are being developed to provide the community with portable, cost effective, and high performance BTX sensing devices in order to effectively monitor the quality of air. In this paper, we study the effect of decorating graphene with tin oxide (SnO2) or tungsten oxide (WO3) nanoparticles on its performance as a chemoresistive material for detecting BTX vapors. Transmission electron microscopy and environmental scanning electron microscopy are used as morphological characterization techniques. SnO2-decorated graphene displayed high sensitivity towards benzene, toluene, and xylene with the lowest tested concentrations of 2 ppm, 1.5 ppm, and 0.2 ppm, respectively. In addition, we found that, by employing these nanomaterials, the observed response could provide a unique double signal confirmation to identify the presence of benzene vapors for monitoring occupational exposure in the textiles, painting, and adhesives industries or in fuel stations.

14 September 2017 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
NBNadra Bohli
Nadra Bohli
HCHanen Chammem
Hanen Chammem
OMOlivier Meilhac
Olivier Meilhac
LMLaurence Mora
Laurence Mora
AAAbdelghani Adnane
Abdelghani Adnane
Glycosylated albumin is considered as a potentially accurate indicator of shorter-term average glucose concentration compared to the current standard HbA1c and as such, it’s attracting the interest of the scientific community as a possible diagnosis marker for diabetic patients. The purpose of this paper is to achieve a better understanding of the glycation effect of albumin on its electrochemical properties. That is done through the use of Interdigitated gold microelectrodes (IDGE) as support in a label free impedimetric immunosensor for detection of human serum albumin detection in glycated (GA) and non-glycated (HSA) form. Anti-human serum albumin, a monoclonal antibody, was physisorbed on the surface of IDGE and used as HSA/GA bioreceptor. Electrochemical Impedance Spectroscopy (EIS), Cyclic Voltammetry (CV), and Surface Plasmon Resonance imaging (SPRi) were used for the characterization of the grafted layers onto the gold surface. A detection range from 1 ng/mL to 401 ng/mL of non glycated HSA antigen in PBS buffer was obtained with the impedance spectroscopy technique. The experiment led to the observation of a significant impedance difference between the glycated and non-glycated antigen of HSA. SPRi measurements confirmed these findings and allowed us to suggest an increase of the dielectric permittivity for human serum albumin upon glycation.

15 February 2022 in Nanotechnology
Verified
Journal Article
Closed access
SBSyrine Behi
Syrine Behi
JCJuan Casanova-Cháfer
Juan Casanova-Cháfer
Ernesto GonzalezErnesto Gonzalez
Ernesto Gonzalez
NBNadra Bohli
Nadra Bohli
Eduard LlobetEduard Llobet
Eduard Llobet
AAAbdelghani Adnane
Abdelghani Adnane
Many research works report a sensitive detection of a wide variety of gas species. However, their in-lab detection is usually performed by using single gases and, therefore, selectivity often remains an unsolved issue. This paper reports a four-sensor array employing different nano-carbon sensitive layers (bare graphene, SnO 2 @Graphene, WO 3 @Graphene, and Au@CNTs). The different gas-sensitive films were characterised via several techniques such as FESEM, TEM, and Raman. First, an extensive study was performed to detect isolated NO 2 , CO 2 , and NH 3 molecules, unravelling the sensing mechanism at the operating temperatures applied. Besides, the effect of the ambient moisture was also evaluated. Afterwards, a model for target gas identification and concentration prediction was developed. Indeed, the sensor array was used in mixtures of NO 2 and CO 2 for studying the cross-sensitivity and developing a calibration model. As a result, the NO 2 detection with different background levels of CO 2 was achieved with an R 2 of 0.987 and an RMSE of about 22 ppb.

4 December 2019 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
NBNadra Bohli
Nadra Bohli
MBMeryem Belkilani
Meryem Belkilani
JCJuan Casanova-Cháfer
Juan Casanova-Cháfer
Eduard LlobetEduard Llobet
Eduard Llobet
AAAbdelghani Adnane
Abdelghani Adnane
Aromatic volatile organic compound (VOC) sensors are attracting growing interest as a response to the pressing market need for sensitive, fast response, low power consumption and stable sensors. Benzene and toluene detection is subject to several potential applications such as air monitoring in chemical industries or even biosensing of human breath. In this work, we report the fabrication of a room temperature toluene and benzene sensor based on multiwall carbon nanotubes (MWCNTs) decorated with gold nanoparticles and functionalised with a long-chain thiol self-assembled monolayer, 1-hexadecanethiol (HDT). High-resolution transmission electron microscopy (HRTEM) and Fourier transform infrared spectroscopy (FTIR) were performed to characterize the gold nanoparticle decoration and to examine the thiol monolayer bonding to the MWCNTs. The detection of aromatic vapours using Au-MWCNT and HDT/Au-MWCNT sensors down to the ppm range shows that the presence of the self-assembled layer increases the sensitivity (up to 17 times), selectivity and improves the response dynamics of the sensors.

29 May 2019 in Micro & Nano Letters
Verified
Journal Article
Open access
PDF file
NBNadra Bohli
Nadra Bohli
MBMeryem Belkilani
Meryem Belkilani
LMLaurence Mora
Laurence Mora
AAAbdelghani Adnane
Abdelghani Adnane
Electrochemical immunosensors are generally layer‐by‐layer or sandwich systems designed to detect an analyte in a solution. Immunosensors are mainly based on the high affinity and specificity of the antibody towards its antigen. This work aims to answer the following question: if we ‘flip’ the immunosensor and build it backwards, thus detecting the antibody with the antigen instead of detecting the antigen with the antibody, will we obtain the same immunosensors properties or not? To answer this question, they tested a system composed of glycated human serum albumin and antibody‐functionalised gold nanoparticles. Impedance spectrum results showed a difference in both the sensitivity and linear range of the built impedimetric immunosensors. The sensitivity of the sensor using the antibody as a bioreceptor was approximated to 0.32 [%. [% (Glycated to total albumin])] − 1] against a sensitivity of 0.80 [%. [% (Glycated to total albumin])] − 1] for the ‘upside‐down’ sensor, using the antigen as a bioreceptor. This study observed also a shift to high glycation levels in the linear range of the upside‐down sensor. These differences could be explained by the effect of steric hindrance and a higher degree of freedom allowing better characteristics for the upside‐down immunosensor.