Franz Baudenbacher

Prof. Dr. Franz Baudenbacher

Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2005 in Review of Scientific Instruments
Verified
Journal Article
Closed access
LFL. E. Fong
L. E. Fong
JHJ. R. Holzer
J. R. Holzer
KMK. K. McBride
K. K. McBride
ELE. A. Lima
E. A. Lima
Franz BaudenbacherFranz Baudenbacher
Franz Baudenbacher
MRM. Radparvar
M. Radparvar
We have developed a scanning superconducting quantum interference device (SQUID) microscope system with interchangeable sensor configurations for imaging magnetic fields of room-temperature (RT) samples with submillimeter resolution. The low-critical-temperature (Tc) niobium-based monolithic SQUID sensors are mounted on the tip of a sapphire and thermally anchored to the helium reservoir. A 25μm sapphire window separates the vacuum space from the RT sample. A positioning mechanism allows us to adjust the sample-to-sensor spacing from the top of the Dewar. We achieved a sensor-to-sample spacing of 100μm, which could be maintained for periods of up to four weeks. Different SQUID sensor designs are necessary to achieve the best combination of spatial resolution and field sensitivity for a given source configuration. For imaging thin sections of geological samples, we used a custom-designed monolithic low-Tc niobium bare SQUID sensor, with an effective diameter of 80μm, and achieved a field sensitivity of 1.5pT∕Hz1∕2 and a magnetic moment sensitivity of 5.4×10−18Am2∕Hz1∕2 at a sensor-to-sample spacing of 100μm in the white noise region for frequencies above 100Hz. Imaging action currents in cardiac tissue requires a higher field sensitivity, which can only be achieved by compromising spatial resolution. We developed a monolithic low-Tc niobium multiloop SQUID sensor, with sensor sizes ranging from 250μm to 1mm, and achieved sensitivities of 480–180fT∕Hz1∕2 in the white noise region for frequencies above 100Hz, respectively. For all sensor configurations, the spatial resolution was comparable to the effective diameter and limited by the sensor-to-sample spacing. Spatial registration allowed us to compare high-resolution images of magnetic fields associated with action currents and optical recordings of transmembrane potentials to study the bidomain nature of cardiac tissue or to match petrography to magnetic field maps in thin sections of geological samples.

8 February 2022 in JCI Insight
Verified
Journal Article
Open access
PDF file
DBDaniel J. Blackwell
Daniel J. Blackwell
MFMichela Faggioni
Michela Faggioni
MWMatthew J. Wleklinski
Matthew J. Wleklinski
NGNieves Gomez-Hurtado
Nieves Gomez-Hurtado
RVRaghav Venkataraman
Raghav Venkataraman
BKBjorn C. Knollmann
Bjorn C. Knollmann
Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an arrhythmia syndrome caused by gene mutations that render RYR2 Ca release channels hyperactive, provoking spontaneous Ca release and delayed afterdepolarizations (DADs). What remains unknown is the cellular source of ventricular arrhythmia triggered by DADs: Purkinje cells in the conduction system or ventricular cardiomyocytes in the working myocardium. To answer this question, we used a genetic approach in mice to knock out cardiac calsequestrin either in Purkinje cells or in ventricular cardiomyocytes. Total loss of calsequestrin in the heart causes a severe CPVT phenotype in mice and humans. We found that loss of calsequestrin only in ventricular myocytes produced a full-blown CPVT phenotype, whereas mice with loss of calsequestrin only in Purkinje cells were comparable to WT mice. Subendocardial chemical ablation or restoration of calsequestrin expression in subendocardial cardiomyocytes neighboring Purkinje cells was sufficient to protect against catecholamine-induced arrhythmias. In silico modeling demonstrated that DADs in ventricular myocardium can trigger full action potentials in the Purkinje fiber, but not vice versa. Hence, ectopic beats in CPVT are likely generated at the Purkinje–myocardial junction via a heretofore unrecognized tissue mechanism, whereby DADs in the ventricular myocardium trigger full action potentials in adjacent Purkinje cells.

20 March 2008 in Analytical Chemistry
Verified
Journal Article
Closed access
JXJunkai Xu
Junkai Xu
RRRon Reiserer
Ron Reiserer
JTJoel Tellinghuisen
Joel Tellinghuisen
†W† John P. Wikswo
† John P. Wikswo
Franz BaudenbacherFranz Baudenbacher
Franz Baudenbacher

1 October 2010 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
IGIgor A. Ges
Igor A. Ges
Franz BaudenbacherFranz Baudenbacher
Franz Baudenbacher

3 February 2016 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
RHRene Harder
Rene Harder
ADAndre Diedrich
Andre Diedrich
JWJonathan S. Whitfield
Jonathan S. Whitfield
MBMaciej Buchowski
Maciej Buchowski
JPJohn B. Pietsch
John B. Pietsch
Franz BaudenbacherFranz Baudenbacher
Franz Baudenbacher
Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r 2 =0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.

1 April 2012 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
IGIgor A. Ges
Igor A. Ges
KCKevin P.M. Currie
Kevin P.M. Currie
Franz BaudenbacherFranz Baudenbacher
Franz Baudenbacher