Geoff Tansley

Geoff Tansley

Auto-generated profile, based on publicly available information

Geoff Tansley


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Microcirculation
Verified
Journal Article
Open access
PDF file
AMAntony P. McNamee
Antony P. McNamee
GTGeoff D. Tansley
Geoff D. Tansley
MSMichael Simmonds
Michael Simmonds
Blood exposure to supraphysiological shear stress within mechanical circulatory support is suspected of reducing red blood cell (RBC) deformability and being primal in the pathogenesis of several secondary complications. No prior works have explored RBC dynamics with the resolution required to determine shear elastic modulus, and/or cell capillary velocity, following exposure to mechanical stresses. Healthy RBCs were exposed to 0, 5, 50, and 100 Pa in a Couette shearing system. For comparison, blood was also exposed to heat treatment—a method that predictably increases RBC rigidity. Shear modulus assessment required aspiration of single RBCs through narrow micropipettes at known suction force. Cell transit velocities were measured within microchannels in regions of fully developed flow. Supraphysiological shear stress increased the elastic shear modulus by 39% and 69% following exposure to 50 and 100Pa, respectively. Cell transit velocity, however, did not change following shear, with concurrent decreases in cell volume likely nullifying increased shear modulus‐friction interactions. Differences observed were consistent with our internal control (heat treatment), supporting that cell mechanics are significantly impaired following supraphysiological‐sublethal shear exposure. Given mechanical circulatory support operates at shear stresses consistent with the present study, it is plausible that these devices induce fundamental impairment to the material properties of RBCs.

30 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
FGFarya Golesorkhie
Farya Golesorkhie
Fuwen YangFuwen Yang
Fuwen Yang
LVLjubo Vlacic
Ljubo Vlacic
GTGeoff Tansley
Geoff Tansley
Power quality and energy efficiency are of great importance in motor control. The motor of any medical device needs to have a smooth torque and minimal vibration in order to maximise its energy efficiency and patient comfort. Furthermore, in rotary blood pumps, excessive energy wasted due to vibration is converted into uncontrolled movement of the mechanical parts and thus could reduce the life of the motor-pump. Besides mechanical or hydraulic origin, one of the causes of vibration in any pump is torque ripple resulting from motor phase commutation. In this paper, using relevant equipment, two extreme scenarios were examined for vibration and electrical efficiency comparison due to power quality in a blood pump: one trapezoidal control with a trapezoidal phase current output; the other a field oriented control (FOC) with a non-distorted sinusoidal phase current. The test motor-pump was the Arteriovenous Fistula Eligibility (AFE) System that is used prior to haemodialysis. The trapezoidal technique was implemented utilising the Allegro a4941 fan driver (Allegro Microsystem, 2012), and the FOC technique was implemented using the Texas Instrument digital signal processor (TMS320F28335). The aim was to reduce the energy wasted over vibration, and to achieve smooth operation of the AFE System. Vibration was measured with a one-axis accelerometer; results showed considerably lower vibration due to less current ripple associated with the FOC control as well as lower power consumption.

17 January 2018 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
JPJo P. Pauls
Jo P. Pauls
LRLlion Roberts
Llion Roberts
TBTom Burgess
Tom Burgess
John Francis FraserJohn Francis Fraser
John Francis Fraser
SGShaun / D. Gregory
Shaun / D. Gregory
GTGeoff Tansley
Geoff Tansley
Rotary blood pumps (RBPs) used for mechanical circulatory support of heart failure patients cannot passively change pump flow sufficiently in response to frequent variations in preload induced by active postural changes. A physiological control system that mimics the response of the healthy heart is needed to adjust pump flow according to patient demand. Thus, baseline data are required on how the healthy heart and circulatory system (i.e., heart rate (HR) and cardiac output (CO)) respond. This study investigated the response times of the healthy heart during active postural changes (supine-standing-supine) in 50 healthy subjects (27 male/23 female). Early response times (te) and settling times (ts) were calculated for HR and CO from data continuously collected with impedance cardiography. The initial circulatory response of HR and CO resulted in te of 9.0–11.7 s when standing up and te of 4.7–5.7 s when lying back down. Heart rate and CO settled in ts of 50.0–53.6 s and 46.3–58.2 s when standing up and lying down, respectively. In conclusion, when compared to active stand up, HR and CO responded significant faster initially when subjects were lying down (p < 0.05); there were no significant differences in response times between male and female subjects. These data will be used during evaluation of physiological control systems for RBPs, which may improve patient outcomes for end-stage heart failure patients.

4 July 2020 in Prosthesis
Verified
Journal Article
Open access
PDF file
Muhammad Sana Ullah SaharMuhammad Sana Ullah Sahar
Muhammad Sana Ullah Sahar
MBMatthew Barton
Matthew Barton
GTGeoffrey Tansley
Geoffrey Tansley
Nerve prostheses are widely utilized to reconstruct segmental (gap) defects in peripheral nerves as an alternative to nerve grafting. However, with increasing gap length, the effectiveness of a nerve prosthesis becomes sub-optimal, which subsequently has made repairing larger gaps in peripheral nerves a significant challenge in the field of regenerative medicine. Recently, the structure of nerve prostheses has been significantly revised, which interestingly, has provided a promising avenue for the housing and proliferation of supportive cells. In this systematic review, cell implantation in synthetic nerve prostheses to enhance the regenerative capability of an injured nerve with a focus on identifying the cell type and mode of cell delivery is discussed. Of interest are the studies employing supportive cells to bridge gaps greater than 10 mm without the aid of nerve growth factors. The results have shown that cell therapy in conjunction with nerve prostheses becomes inevitable and has dramatically boosted the ability of these prostheses to maintain sustainable nerve regeneration across larger gaps and helped to attain functional recovery, which is the ultimate goal. The statistical analysis supports the use of differentiated bone-marrow-derived mesenchymal stem cells suspended in oxygen-carrying hydrogels in chitosan prostheses for bridging gaps of up to 40 mm; however, based on the imperfect repair outcomes, nerve grafting should not yet be replaced altogether.