Fengfeng Zhang

Dr. Fengfeng Zhang

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
LCLong Chen
Long Chen
FZFengfeng Zhang
Fengfeng Zhang
WZWei Zhan
Wei Zhan
MGMinfeng Gan
Minfeng Gan
LSLining Sun
Lining Sun
Background: The traditional navigation interface was intended only for two-dimensional observation by doctors; thus, this interface does not display the total spatial information for the lesion area. Surgical navigation systems have become essential tools that enable for doctors to accurately and safely perform complex operations. The image navigation interface is separated from the operating area, and the doctor needs to switch the field of vision between the screen and the patient’s lesion area. In this paper, augmented reality (AR) technology was applied to spinal surgery to provide more intuitive information to surgeons. The accuracy of virtual and real registration was improved via research on AR technology. During the operation, the doctor could observe the AR image and the true shape of the internal spine through the skin. Methods: To improve the accuracy of virtual and real registration, a virtual and real registration technique based on an improved identification method and robot-assisted method was proposed. The experimental method was optimized by using the improved identification method. X-ray images were used to verify the effectiveness of the puncture performed by the robot. Results: The final experimental results show that the average accuracy of the virtual and real registration based on the general identification method was 9.73 ± 0.46 mm (range 8.90–10.23 mm). The average accuracy of the virtual and real registration based on the improved identification method was 3.54 ± 0.13 mm (range 3.36–3.73 mm). Compared with the virtual and real registration based on the general identification method, the accuracy was improved by approximately 65%. The highest accuracy of the virtual and real registration based on the robot-assisted method was 2.39 mm. The accuracy was improved by approximately 28.5% based on the improved identification method. Conclusion: The experimental results show that the two optimized methods are highly very effective. The proposed AR navigation system has high accuracy and stability. This system may have value in future spinal surgeries.

10 June 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
LCLong Chen
Long Chen
LMLi Ma
Li Ma
FZFengfeng Zhang
Fengfeng Zhang
XYXinrong Yang
Xinrong Yang
LSLining Sun
Lining Sun

1 January 2020 in IEEE Access
Verified
Journal Article
Open access
LCLong Chen
Long Chen
FZFengfeng Zhang
Fengfeng Zhang
LSLining Sun
Lining Sun
The Back Propagation (BP) neural network has the problems of low accuracy and poor convergence in the process of binocular camera calibration. A method based on BP neural network optimized by improved genetic simulated annealing algorithm (IGSAA-BP) is proposed to solve these problems to complete the binocular camera calibration. The method of combining Gaussian scale space and Harris corner detection operator is used for corner detection. A matched algorithm of homonymous corner is proposed by combining point-to-point spatial mapping and grid motion statistics. The pixel values of the homonymous corner and three-dimensional coordinate values are taken as the input and output of BP neural network respectively. The crossover and mutation probability of genetic simulated annealing algorithm and the annealing criterion are improved, the IGSAA-BP neural network is used to calibrate the binocular camera. The average calibration accuracy of BP neural network and IGSAA-BP neural network is 0.71mm and 0.03mm, respectively. The average calibration accuracy of binocular camera is improved by 96%. The iteration speed is increased by 20 times and global optimization ability is improved. It can be seen that the IGSAA-BP neural network can improve the calibration accuracy of binocular camera and accelerate convergence speed.

1 April 2016 in Journal of Luminescence
Verified
Journal Article
Closed access
MCMing Chen
Ming Chen
ZWZhi-Chao Wang
Zhi-Chao Wang
BWBaoshan Wang
Baoshan Wang
Feng YangFeng Yang
Feng Yang
GZGuochun Zhang
Guochun Zhang
ZXZu-Yan Xu
Zu-Yan Xu

4 January 2021 in IEEE Access
Verified
Journal Article
Open access
XZXin Zhang
Xin Zhang
LCLong Chen
Long Chen
FZFengfeng Zhang
Fengfeng Zhang
LSLining Sun
Lining Sun
In view of the problem that the doctor cannot quickly obtain the three-dimensional information of the liver surface during the traditional open resection of liver tumor without radiation, a new three-dimensional reconstruction system of liver surface based on binocular structured light is proposed in this paper to obtain three-dimensional information of liver surface rapidly. The hardware construction and software module design of the three-dimensional reconstruction system of the liver surface are carried out. The multi-frequency heterodyne method is proposed to solve the problem of the lack of three-dimensional reconstruction of the liver surface. A GPU-CPU collaborative acceleration method is proposed to speed up the three-dimensional reconstruction of intraoperative liver surface. On this basis, a human respiratory platform is built to simulate the effect of human respiration on three-dimensional reconstruction of the liver surface in a real surgical environment. The accuracy and speed of the system are verified by the liver experiments: The errors of three-dimensional reconstruction of liver surface at expiratory peak and inspiratory peak are 0.78 ± 0.18mm and 0.92 ± 0.21 mm, respectively. The average time required for three-dimensional reconstruction of liver surface based on GPU-CPU collaborative calculation is 3.93s. The speed of three-dimensional reconstruction of liver surface based on GPU-CPU collaborative calculation is 52% faster than that of three-dimensional reconstruction of liver surface based on CPU. It can be seen that the system has high accuracy and fast speed, which can meet the basic needs of the doctor in surgery.

25 December 2019 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
LCLong Chen
Long Chen
FZFengfeng Zhang
Fengfeng Zhang
WZWei Zhan
Wei Zhan
MGMinfeng Gan
Minfeng Gan
LSLining Sun
Lining Sun