Tijmen Bos

Mr. Tijmen Bos

Vrije Universiteit Amsterdam
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2020 in Journal of Separation Science
Verified
Journal Article
Open access
PDF file
TBTijmen Bos
Tijmen Bos
WKWouter C. Knol
Wouter C. Knol
SMStef R.A. Molenaar
Stef R.A. Molenaar
LNLeon E. Niezen
Leon E. Niezen
PSPeter J. Schoenmakers
Peter J. Schoenmakers
BPBob W.J. Pirok
Bob W.J. Pirok
The proliferation of increasingly more sophisticated analytical separation systems, often incorporating increasingly more powerful detection techniques, such as high‐resolution mass spectrometry, causes an urgent need for highly efficient data‐analysis and optimization strategies. This is especially true for comprehensive two‐dimensional chromatography applied to the separation of very complex samples. In this contribution, the requirement for chemometric tools is explained and the latest developments in approaches for (pre‐)processing and analyzing data arising from one‐ and two‐dimensional chromatography systems are reviewed. The final part of this review focuses on the application of chemometrics for method development and optimization.

1 November 2022 in Analytical Chemistry
Verified
Journal Article
Open access
TBTijmen Bos
Tijmen Bos
JBJim Boelrijk
Jim Boelrijk
SMStef R. A. Molenaar
Stef R. A. Molenaar
BVBrian van ’T Veer
Brian van ’T Veer
LNLeon E. Niezen
Leon E. Niezen
BPBob W. J. Pirok
Bob W. J. Pirok
The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesian-optimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).

1 January 2021 in Journal of Chromatography A
Verified
Journal Article
Open access
TBTijmen Bos
Tijmen Bos
LNLeon E. Niezen
Leon E. Niezen
MUMimi J. Den Uijl
Mimi J. Den Uijl
SMStef R.A. Molenaar
Stef R.A. Molenaar
SLSascha Lege
Sascha Lege
BPBob W.J. Pirok
Bob W.J. Pirok
Rapid optimization of gradient liquid chromatographic (LC) separations often utilizes analyte retention modelling to predict retention times as function of eluent composition. However, due to the dwell volume and technical imperfections, the actual gradient may deviate from the set gradient in a fashion unique to the employed instrument. This makes accurate retention modelling for gradient LC challenging, in particular when very fast separations are pursued. Although gradient deformation has been addressed in method-transfer situations, it is rarely taken into account when reporting analyte retention parameters obtained from gradient LC data, hampering the comparison of data from various sources. In this study, a response-function-based algorithm was developed to determine analyte retention parameters corrected for geometry-induced deformations by specific LC instruments. Out of a number of mathematical distributions investigated as response-functions, the so-called "stable function" was found to describe the formed gradient most accurately. The four parameters describing the model resemble the statistical moments of the distribution and are related to chromatographic parameters, such as dwell volume and flow rate. The instrument-specific response function can then be used to predict the actual shape of any other gradient programmed on that instrument. To incorporate the predicted gradient in the retention modelling of the analytes, the model was extended to facilitate an unlimited number of linear gradient steps to solve the equations numerically. The significance and impact of distinct gradient deformation for fast gradients was demonstrated using three different LC instruments. As a proof of principle, the algorithm and retention parameters obtained on a specific instrument were used to predict the retention times on different instruments. The relative error in the predicted retention times went down from an average of 9.8% and 12.2% on the two other instruments when using only a dwell-volume correction to 2.1% and 6.5%, respectively, when using the proposed algorithm. The corrected retention parameters are less dependent on geometry-induced instrument effects.

26 April 2023 in Analytica Chimica Acta
Verified
Journal Article
Open access
HMHany A. Majeed
Hany A. Majeed
TBTijmen Bos
Tijmen Bos
RVRobert L.C. Voeten
Robert L.C. Voeten
RKRuben F. Kranenburg
Ruben F. Kranenburg
AAArian C. van Asten
Arian C. van Asten
IKIsabelle Kohler
Isabelle Kohler
New psychoactive substances (NPS) are synthetic derivatives of illicit drugs designed to mimic their psychoactive effects. NPS are typically not controlled under drug acts or their legal status depends on their molecular structure. Discriminating isomeric forms of NPS is therefore crucial for forensic laboratories. In this study, a trapped ion mobility spectrometry time-of-flight mass spectrometry (TIMS-TOFMS) approach was developed for the identification of ring-positional isomers of synthetic cathinones, a class of compounds representing two-third of all NPS seized in Europe in 2020. The optimized workflow features narrow ion-trapping regions, mobility calibration by internal reference, and a dedicated data-analysis tool, allowing for accurate relative ion-mobility assessment and high-confidence isomer identification. Ortho-, meta- and para-isomers of methylmethcathinone (MMC) and bicyclic ring isomers of methylone were assigned based on their specific ion mobilities within 5 min, including sample preparation and data analysis. The resolution of two distinct protomers per cathinone isomer added to the confidence in identification. The developed approach was successfully applied to the unambiguous assignment of MMC isomers in confiscated street samples. These findings demonstrate the potential of TIMS-TOFMS for forensic case work requiring fast and highly-confident assignment cathinone-drug isomers in confiscated samples.

25 December 2024 in Journal of Chromatography A
Verified
Journal Article
Open access
GHGerben B. van Henten
Gerben B. van Henten
JBJim Boelrijk
Jim Boelrijk
CKCéline Kattenberg
Céline Kattenberg
TBTijmen Bos
Tijmen Bos
BEBernd Ensing
Bernd Ensing
BPBob W.J. Pirok
Bob W.J. Pirok
Optimization algorithms play an important role in method development workflows for gradient elution liquid chromatography. Their effectiveness has not been evaluated for chromatographic method development using standardized comparisons across factors such as sample complexity, chromatographic response functions (CRFs), gradient complexity, and application type. This study compares six optimization algorithms - Bayesian optimization (BO), differential evolution (DE), a genetic algorithm (GA), covariance-matrix adaptation evolution strategy (CMA-ES), random search, and grid search - for the development of gradient elution LC methods. Utilizing a multi-linear retention modeling framework, these algorithms were assessed across diverse samples, CRFs, and gradient segments, considering two observation modes: dry (in silico, deconvoluted), and wet (search-based, requiring peak detection). The optimization algorithms were evaluated based on their data (i.e. number of iterations) and time efficiency. Of the algorithms compared in this study, DE proved to be a highly competitive method for dry optimization purposes in terms of both data and time efficiency. BO outperformed all other algorithms in terms of data efficiency and was found to be most effective for search-based optimization, which requires a low number of iterations (<200). However, BO was found to be impractical for dry optimization requiring a large iteration budget due to its unfavorable computational scaling. It was observed that both the CRF and the sample have a strong influence on the efficiency of the algorithms, emphasizing the need for better benchmark samples and highlighting the importance of assessing CRF-induced complexity in the optimization landscape.

4 April 2025 in Chromatographia
Verified
Journal Article
Open access
PDF file
RHRick S. van Den Hurk
Rick S. van Den Hurk
BPBob W. J. Pirok
Bob W. J. Pirok
TBTijmen Bos
Tijmen Bos
The application of artificial intelligence (AI) and machine learning (ML) is rapidly expanding and has begun to make a significant impact on polymer development and characterization. This perspective article explores the current state of AI in this field and highlights areas where its potential remains underutilized. While the optimization of polymer synthesis to achieve desired properties and the classification of polymer types are well-established, opportunities for AI integration in detailed characterization, analytical method development, and data processing remain largely untapped. Greater automation of the analytical laboratory, whether through dedicated algorithms or AI-driven solutions, will enable analytical chemists to focus more on addressing research questions and interpreting results, rather than on method development and routine measurements.