The usual way to guarantee stability of model predictive control (MPC) strategies is based on a terminal cost function and a terminal constraint region. This note analyzes the stability of MPC when the terminal constraint is removed. This is particularly interesting when the system is unconstrained on the state. In this case, the computational burden of the optimization problem does not have to be increased by introducing terminal state constraints due to stabilizing reasons. A region in which the terminal constraint can be removed from the optimization problem is characterized depending on some of the design parameters of MPC. This region is a domain of attraction of the MPC without terminal constraint. Based on this result, it is proved that weighting the terminal cost, this domain of attraction of the MPC controller without terminal constraint is enlarged reaching (practically) the same domain of attraction of the MPC with terminal constraint; moreover, a practical procedure to calculate the stabilizing weighting factor for a given initial state is shown. Finally, these results are extended to the case of suboptimal solutions and an asymptotically stabilizing suboptimal controller without terminal constraint is presented.
The interest in variable-speed multiphase induction- motor drives has substantially increased in recent years and novel proposals show good prospects for industrial implementation in high-power applications. The additional degrees of freedom existing in multiphase machines have allowed for new applications with high torque density by current harmonic injection in concentrated winding machines. This paper addresses, for the first time, the bifurcation analysis of a five-phase induction-motor drive when a third harmonic is injected for torque-enhancement purposes. The main focus of this paper is to present a mathematically based study of the nonlinear dynamics of the proposed drive with torque enhancement. The overall bifurcation analysis for both concentrated and distributed winding machines confirms that the harmonic injection provides not only torque enhancement but also more robust controllers. This further advantage offers improved performance of multiphase drives compared to their three-phase counterparts.
This paper addresses the problems associated with the dc-link capacitor voltages of the three-level neutral-point-clamped power converter: the imbalance of the capacitor voltages as well as the presence of an ac-voltage low-frequency oscillation in the dc link of the converter. In order to cope with them, a mathematical analysis of the capacitor voltage difference dynamics, based on a direct average continuous model, is carried out, considering a singular perturbation approach. The analysis leads to a final expression where a sinusoidal disturbance appears explicitly. Consequently, the two problems can be handled together using the ordinary formulation of a problem of regulating the output of a system subject to sinusoidal disturbances, applying classical control theory to design the controller. In this way, the controller is designed including the disturbance estimate provided by a Luenberger observer to asymptotically cancel the disturbance, while keeping also balanced the capacitor voltages. Experiments for a synchronous three-level neutral-point-clamped converter prototype are carried out to evaluate the performance and usefulness of the converter working as a grid-connected inverter under the proposed control law.MICINN-FEDER DPI2009-09661Junta de Andalucía P07-TIC-0299