JORGE A. CALVO-SANZ

Dr. JORGE A. CALVO-SANZ


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
APAlejandro Portero-Benito
Alejandro Portero-Benito
AAAlfonso Arias-Puente
Alfonso Arias-Puente

2 July 2020 in Chronobiology International
Verified
Journal Article
Closed access
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
CTCarlos E Tapia-Ayuga
Carlos E Tapia-Ayuga
Blue light, with wavelengths shorter than 440–450 nm, is the most energetic radiation of the visible spectrum for the human eye, and its possible multiple effects on the human nervous and other systems have become a line of research by many investigators. The use of mobile devices whose screens emit various amounts of blue light is common nowadays. This study evaluated the efficiency of the blue light screen and control software technologies of eight different mobile devices. Emitted screen spectra of the different mobile devices according to different conditions of blue light emission software control were obtained using a spectrograph, and the derived spectra were compared with the melatonin suppression action spectrum. The amount of blue light emission and predicted melatonin suppression varied according to the unique software control and screen technology of each device. AMOLED screen technology, compared with other screen technologies, achieved better control of blue light emission. The effect of blue light filters depends on the screen technology; however, the melatonin suppression index of mobile devices is not reduced sufficiently by the use of blue light-attenuating software.

1 January 2020 in Journal of Optometry
Verified
Journal Article
Open access
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
MSMiguel A. Sánchez-Tena
Miguel A. Sánchez-Tena
To characterize the optical performance of two models of refractive bifocal intraocular lenses, with medium and high addition, using defocus curves. 20 eyes from 20 subjects were included in this study. 10 eyes underwent caratact surgery with an implant of a medium addition refractive bifocal intraocular lens (IOL) (Lentis LS-313 MF20) and the other 10 eyes underwent cataract surgery with an implant of a high addition refractive bifocal IOL (Lentis LS-313 MF30). Six weeks after surgery, subjective refraction and defocus curve were made. Mean final residual refraction in spherical equivalent was +0.10±0.07D in the LS-313MF30 group and +0.12±0.10D in the LS-313MF20 group. Defocus curve showed a different optical performance in intermediate/near distance depending on the IOL model. The medium addition IOL provided good visual acuity (VA) at far and intermediate distance up to 50cms, and the high addition IOL provided better VA in near distance up to 25cms. The high addition intraocular lens provides better visual acuity in the spatial range from infinity to the point close to 25cm. The medium addition intraocular lens provides excellent visual acuity in far and intermediate vision. The defocus curve seems to be a valid and reproducible tool for evaluating the optical behavior of multifocal sector refractive lenses.

1 July 2018 in Journal of Optometry
Verified
Journal Article
Open access
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
JRJavier Ruiz-Alcocer
Javier Ruiz-Alcocer
MSMiguel A. Sánchez-Tena
Miguel A. Sánchez-Tena
To compare and analyze the interchangeability of three measuring systems, each based on a different technique, for central corneal thickness (CCT) analysis. CCT measurements were measured using optical coherence tomography (OCT), non-contact specular microscopy (NCSM), and ultrasonic pachymetry (USP) in 60 eyes of 60 healthy patients with a mean age of 66.5±15.0 years and a mean spherical equivalent of 0.43±1.14 D. Analysis of variations in measurement concordance and correlation among the three different methods were performed. Comparison of CCT measurements were done using Bland-Altman plots (with bias and 95% confidence intervals), intraclass correlation coefficient (ICC), and paired t-student analysis. Mean CCT values were: 549.20±26.91μm for USP (range 503-618μm), 514.20±27.49μm for NCSM (range 456-586μm) and 542.80±25.56μm for OCT (range 486-605μm). CCT values obtained with NCMS were significantly lower than those obtained with OCT and USP methods. NCMS CCT value was 36.08±10.72μm lower than USP value (p<0.05), and NCMS CCT value was 7.88±8.86μm lower than OCT value (p<0.05). ICC between USP-NCSM pair was 0.488 and 0.909 between USP-OCT pair. OCT and UPS offered highly comparable results, whereas NCSM offered lower mean CCT values compared to the other two methods. Therefore, NCSM should not be considered a reliable method for measuring CCT and should rather be considered for assessing longitudinal changes in the same patient.

28 April 2022 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
FPFrancisco Poyales
Francisco Poyales
YZYing Zhou
Ying Zhou
AAAlfonso Arias-Puente
Alfonso Arias-Puente
NGNuria Garzón
Nuria Garzón
Purpose: To evaluate the agreement between the biometric measurements used to calculate the size of the implantable collamer lenses (ICL) with different technologies: swept-source optical coherence tomography, spectral domain optical coherence tomography, and Scheimpflug tomography. Methods: This retrospective observational study included subjects undergoing refractive surgery with posterior chamber phakic IOL implantation to correct their myopia. The anterior chamber depth (ACD) and the horizontal white to white (WTW) or the angle to angle (ATA) distance were measured with the following four devices: the IOLMaster 700 biometer (Carl Zeiss Meditec, Jena, Germany), based on swept-source optical coherence tomography; the Cirrus and Visante optical coherence tomographs (Carl Zeiss Meditec) based on low-coherence interferometry; and the Pentacam rotating Scheimpflug camera (Oculus, Wetzlar, Germany). Results: In the horizontal corneal diameter measurements, there were statistically significant differences between Pentacam–IOLMaster 700 pair (P < 0.001) and Pentacam–Visante pair (P < 0.001). WTW from CIRRUS showed the lowest correlation when paired with Pentacam and IOLMaster 700 (R 2 = 0.452 and 0.385 for Visante and R 2 = 0.494 and 0.426 for Cirrus). Regarding the linear correlation of the ACD measurements, all pairs of devices were statistically significant and all of them showed a very good correlation index. Conclusion: There is a good agreement between the different devices under evaluation for ACD measurements. As for WTW, the values measured with the different devices showed large discrepancies with low correlation levels, especially when comparing the tomographs with the other devices under evaluation.

22 March 2018 in European Journal of Ophthalmology
Verified
Journal Article
Open access
NJNuria Garzón Jimenez
Nuria Garzón Jimenez
MRManuel Rodríguez-Vallejo
Manuel Rodríguez-Vallejo
DCDavid Carmona
David Carmona
JCJORGE A. CALVO-SANZ
JORGE A. CALVO-SANZ
FPFrancisco Poyales
Francisco Poyales
JFJoaquín Fernández
Joaquín Fernández
Purpose: To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (KSIM) or total corneal refractive power (TCRP) after temporal incisions. Methods: Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with KSIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with KSIM astigmatism <0.90 D and HIGH with KSIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis. Results: Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with KSIM, versus 0.28 D @ 90° with TCRP3, but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between KSIM- and TCRP3-based surgically induced astigmatism values were negligible in LOW group. Conclusion: Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the KSIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.