Maria Adele Marino

Dr. Maria Adele Marino

Department of Biomedical Sciences and Morphologic and Functional Imaging, University of Messina, Messina, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2019 in The Oncologist
Verified
Journal Article
Open access
PDF file
MMMaria Adele Marino
Maria Adele Marino
DADaly Avendano
Daly Avendano
PZPedro Zapata
Pedro Zapata
CRChristopher C. Riedl
Christopher C. Riedl
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
The detection of lymph node metastasis affects the management of patients with primary breast cancer significantly in terms of staging, treatment, and prognosis. The main goal for the radiologist is to determine and detect the presence of metastatic disease in nonpalpable axillary lymph nodes with a positive predictive value that is high enough to initially select patients for upfront axillary lymph node dissection. Features that are suggestive of axillary adenopathy may be seen with different imaging modalities, but ultrasound is the method of choice for evaluating axillary lymph nodes and for performing image-guided lymph node interventions. This review aims to provide a comprehensive overview of the available imaging modalities for lymph node assessment in patients diagnosed with primary breast cancer.

8 September 2018 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
DLDoris Leithner
Doris Leithner
LMLinda Moy
Linda Moy
EMElizabeth A Morris
Elizabeth A Morris
MMMaria Adele Marino
Maria Adele Marino
THThomas H Helbich
Thomas H Helbich
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
MRI of the breast is the most sensitive test for breast cancer detection and outperforms conventional imaging with mammography, digital breast tomosynthesis, or ultrasound. However, the long scan time and relatively high costs limit its widespread use. Hence, it is currently only routinely implemented in the screening of women at an increased risk of breast cancer. To overcome these limitations, abbreviated dynamic contrast‐enhanced (DCE)‐MRI protocols have been introduced that substantially shorten image acquisition and interpretation time while maintaining a high diagnostic accuracy. Efforts to develop abbreviated MRI protocols reflect the increasing scrutiny of the disproportionate contribution of radiology to the rising overall healthcare expenditures. Healthcare policy makers are now focusing on curbing the use of advanced imaging examinations such as MRI while continuing to promote the quality and appropriateness of imaging. An important cornerstone of value‐based healthcare defines value as the patient's outcome over costs. Therefore, the concept of a fast, abbreviated MRI exam is very appealing, given its high diagnostic accuracy coupled with the possibility of a marked reduction in the cost of an MRI examination. Given recent concerns about gadolinium‐based contrast agents, unenhanced MRI techniques such as diffusion‐weighted imaging (DWI) are also being investigated for breast cancer diagnosis. Although further larger prospective studies, standardized imaging protocol, and reproducibility studies are necessary, initial results with abbreviated MRI protocols suggest that it seems feasible to offer screening breast DCE‐MRI to a broader population. This article aims to give an overview of abbreviated and fast breast MRI protocols, their utility for breast cancer detection, and their emerging role in the new value‐based healthcare paradigm that has replaced the fee‐for‐service model.Level of Evidence: 1Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;49:e85–e100.

22 June 2017 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
MMMaria Adele Marino
Maria Adele Marino
THThomas Helbich
Thomas Helbich
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig

12 September 2019 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
DLDoris Leithner
Doris Leithner
JHJoao V. Horvat
Joao V. Horvat
MMMaria Adele Marino
Maria Adele Marino
BBBlanca Bernard-Davila
Blanca Bernard-Davila
MJMaxine Jochelson
Maxine Jochelson
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
Background: To evaluate the diagnostic performance of radiomic signatures extracted from contrast-enhanced magnetic resonance imaging (CE-MRI) for the assessment of breast cancer receptor status and molecular subtypes. Methods: One hundred and forty-three patients with biopsy-proven breast cancer who underwent CE-MRI at 3 T were included in this IRB-approved HIPAA-compliant retrospective study. The training dataset comprised 91 patients (luminal A, n = 49; luminal B, n = 8; HER2-enriched, n = 11; triple negative, n = 23), while the validation dataset comprised 52 patients from a second institution (luminal A, n = 17; luminal B, n = 17; triple negative, n = 18). Radiomic analysis of manually segmented tumors included calculation of features derived from the first-order histogram (HIS), co-occurrence matrix (COM), run-length matrix (RLM), absolute gradient (GRA), autoregressive model (ARM), discrete Haar wavelet transform (WAV), and lesion geometry (GEO). Fisher, probability of error and average correlation (POE + ACC), and mutual information coefficients were used for feature selection. Linear discriminant analysis followed by k-nearest neighbor classification (with leave-one-out cross-validation) was used for pairwise radiomic-based separation of receptor status and molecular subtypes. Histopathology served as the standard of reference. Results: In the training dataset, radiomic signatures yielded the following accuracies > 80%: luminal B vs. luminal A, 84.2% (mainly based on COM features); luminal B vs. triple negative, 83.9% (mainly based on GEO features); luminal B vs. all others, 89% (mainly based on COM features); and HER2-enriched vs. all others, 81.3% (mainly based on COM features). Radiomic signatures were successfully validated in the separate validation dataset for luminal A vs. luminal B (79.4%) and luminal B vs. triple negative (77.1%). Conclusions: In this preliminary study, radiomic signatures with CE-MRI enable the assessment of breast cancer receptor status and molecular subtypes with high diagnostic accuracy. These results need to be confirmed in future larger studies.

27 February 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
JHJoao V. Horvat
Joao V. Horvat
BBBlanca Bernard‐Davila
Blanca Bernard‐Davila
THThomas H. Helbich
Thomas H. Helbich
MZMichelle Zhang
Michelle Zhang
EMElizabeth A. Morris
Elizabeth A. Morris
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
Background: Diffusion‐weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping is one of the most useful additional MRI parameters to improve diagnostic accuracy and is now often used in a multiparameric imaging setting for breast tumor detection and characterization.Purpose: To evaluate whether different ADC metrics can also be used for prediction of receptor status, proliferation rate, and molecular subtype in invasive breast cancer.Study Type: Retrospective.Subjects: In all, 107 patients with invasive breast cancer met the inclusion criteria (mean age 57 years, range 32–87) and underwent multiparametric breast MRI.Field Strength/Sequence: 3 T, readout‐segmented echo planar imaging (rsEPI) with IR fat suppression, dynamic contrast‐enhanced (DCE) T1‐weighted imaging, T2‐weighted turbo‐spin echo (TSE) with fatsat.Assessment: Two readers independently drew a region of interest on ADC maps on the whole tumor (WTu), and on its darkest part (DpTu). Minimum, mean, and maximum ADC values of both WTu and DpTu were compared for receptor status, proliferation rate, and molecular subtypes.Statistical Tests: Wilcoxon rank sum, Mann–Whitney U‐tests for associations between radiologic features and histopathology; histogram and q‐q plots, Shapiro–Wilk's test to assess normality, concordance correlation coefficient for precision and accuracy; receiver operating characteristics curve analysis.Results: Estrogen receptor (ER) and progesterone receptor (PR) status had significantly different ADC values for both readers. Maximum WTu (P = 0.0004 and 0.0005) and mean WTu (P = 0.0101 and 0.0136) were significantly lower for ER‐positive tumors, while PR‐positive tumors had significantly lower maximum WTu values (P = 0.0089 and 0.0047). Maximum WTu ADC was the only metric that was significantly different for molecular subtypes for both readers (P = 0.0100 and 0.0132) and enabled differentiation of luminal tumors from nonluminal (P = 0.0068 and 0.0069) with an area under the curve of 0.685 for both readers.Data Conclusion: Maximum WTu ADC values may be used to differentiate luminal from other molecular subtypes of breast cancer.Level of Evidence: 3Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;50:836–846.

14 January 2021 in Clinical Cancer Research
Verified
Journal Article
Open access
PDF file
PCPaola Clauser
Paola Clauser
BKBarbara Krug
Barbara Krug
HBHubert Bickel
Hubert Bickel
MDMatthias Dietzel
Matthias Dietzel
KPKatja Pinker
Katja Pinker
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
Purpose: Diffusion-weighted imaging with the calculation of an apparent diffusion coefficient (ADC) has been proposed as a quantitative biomarker on contrast-enhanced MRI (CE-MRI) of the breast. There is a need to approve a generalizable ADC cutoff. The purpose of this study was to evaluate whether a predefined ADC cutoff allows downgrading of BI-RADS 4 lesions on CE-MRI, avoiding unnecessary biopsies. Experimental Design: This was a retrospective, multicentric, cross-sectional study. Data from five centers were pooled on the individual lesion level. Eligible patients had a BI-RADS 4 rating on CE-MRI. For each center, two breast radiologists evaluated the images. Data on lesion morphology (mass, non-mass), size, and ADC were collected. Histology was the standard of reference. A previously suggested ADC cutoff (≥1.5 × 10−3 mm2/second) was applied. A negative likelihood ratio of 0.1 or lower was considered as a rule-out criterion for breast cancer. Diagnostic performance indices were calculated by ROC analysis. Results: There were 657 female patients (mean age, 42; SD, 14.1) with 696 BI-RADS 4 lesions included. Disease prevalence was 59.5% (414/696). The area under the ROC curve was 0.784. Applying the investigated ADC cutoff, sensitivity was 96.6% (400/414). The potential reduction of unnecessary biopsies was 32.6% (92/282). Conclusions: An ADC cutoff of ≥1.5 × 10−3 mm2/second allows downgrading of lesions classified as BI-RADS 4 on breast CE-MRI. One-third of unnecessary biopsies could thus be avoided.