Fang Tian

Dr. Fang Tian

Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin International Joint Research and Development Centre of Ophthalmology and Vision Science, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2019 in Journal of Cellular and Molecular Medicine
Verified
Journal Article
Open access
PDF file
JYJun Yang
Jun Yang
SZShaozhen Zhao
Shaozhen Zhao
FTFang Tian
Fang Tian
Emerging evidence illustrates the critical roles of long non‐coding RNAs (lncRNAs) in the diabetes. However, the deepgoing regulation of lncRNA PVT1 in the diabetic cataract (DC) is still unclear. Here, present research investigates the pathologic roles and underlying mechanism by which lncRNA PVT1 regulates the DC pathogenesis. Human lens epithelial (HLE) B‐3 cells were induced by the high glucose (HG) to simulate the DC microenvironment models. Results revealed that lncRNA PVT1 expression was up‐regulated in the HG‐induced HLE B‐3 cells as compared to the normal glucose group. Transcription factor SP1 could bind with the promoter region of PVT1 and activate its transcription. Functionally, PVT1 knock‐down could repress the proliferation and promote the apoptosis of HLE B‐3 cells. Mechanistically, PVT1 acted as the ‘miRNA sponge’ to target miR‐214‐3p/MMP2 axis. This finding revealed a novel insight of lncRNA PVT1 for the DC pathogenesis, providing an inspiration for the DC mechanism.

Verified
Journal Article
Open access
PDF file
FTFang Tian
Fang Tian
LDLijie Dong
Lijie Dong
YZYu Zhou
Yu Zhou
YSYan Shao
Yan Shao
WLWenbo Li
Wenbo Li
FWFei Wang
Fei Wang
Hepatocyte growth factor (HGF) induced the proliferation of lens epithelial cells (LECs) and may be a major cause of posterior capsule opacification (PCO), which is the most frequent postoperative complication of cataract surgery. To date, several agents that can block LECs proliferation have been studied, but none have been used in clinic. Recently, accumulating evidence has suggested rapamycin, the inhibitor of mTOR (mammalian target of Rapamycin), was associated with the induction of apoptosis in LECs. The purpose of our study was to investigate the potential effects of rapamycin on HGF-induced LECs and the underlying mechanisms by which rapamycin exerted its actions. Using cell proliferation, cell viability and flow cytometric apoptosis assays, we found that rapamycin potently not only suppressed proliferation but also induced the apoptosis of LECs in a dose-dependent manner under HGF administration. Further investigation of the underlying mechanism using siRNA transfection revealed that rapamycin could promote apoptosis of LECs via inhibiting HGF-induced phosphorylation of AKT/mTOR, ERK and JAK2/STAT3 signaling molecules. Moreover, the forced expression of AKT, ERK and STAT3 could induce a significant suppression of apoptosis in these cells after treatment of rapamycin. Together, these findings suggested that rapamycin-induced apoptosis in HGF-stimulated LECs is accompanied by inhibition of AKT/mTOR, ERK and JAK2/STAT3 pathways, which supports its use to inhibit PCO in preclinical studies and provides theoretical foundation for future possible practice.

5 March 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
XXXiaoli Xing
Xiaoli Xing
LHLiangyu Huang
Liangyu Huang
FTFang Tian
Fang Tian
YZYan Zhang
Yan Zhang
YLYingjuan Lv
Yingjuan Lv
ALAihua Liu
Aihua Liu
Background: To compare the anterior biometrics in eyes with secondary acute angle closure induced by occult lens subluxation (ASAC-LS), misdiagnosed as acute primary angle closure (APAC) at the first visit with APAC, chronic primary angle closure glaucoma (CPACG), and cataract. Methods: This retrospective case study included 17 eyes with angel closure due to occult LS, who were misdiagnosed as APAC on their first visit, 56 APAC eyes, 54 CPACG eyes, and 56 cataract eyes. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD) and lens thickness (LT) were recorded. Lens position (LP), relative lens position (RLP), corrected lens position (CLP) were calculated. Quantitative data were subject to one-way analysis of variance and correlation analysis. Categorical data were analyzed using the chi-squared test. Receiver operating characteristic (ROC) curves were plotted to obtain a suitable cutoff value of ocular biometrics. Results: The ASAC-LS patients had a longer ocular axial length than APAC and CPACG patients. Central corneal thickness of the ASAC-LS patients was not significantly different from APAC patients, but was significantly different from CPACG and cataract patients. The APAC patients had the smallest ACD, while the ASAC-LS patients had the smallest AD. The ASAC-LS patients had the largest lens thickness. According to ROC curve analysis, RLP, ACD, AD, CLP, LP had high power of discrimination. Conclusions: This study revealed that LS secondary PAC patients had a shallower AD, thicker CCT comparing to those of APAC, CPACG and cataract patients. For patients with acute angle-closure glaucoma, it is necessary to exclude lens zonula relaxation. Trial registration: NCT03752710, retrospectively registered.

3 February 2025 in Advances in Ophthalmology Practice and Research
Verified
Journal Article
Open access
YJYuanfeng Jiang
Yuanfeng Jiang
XCXiteng Chen
Xiteng Chen
YGYichen Gao
Yichen Gao
NGNan Gao
Nan Gao
HWHuiyu Wang
Huiyu Wang
FTFang Tian
Fang Tian
This prospective cohort study aimed to assess the influence of tear film stability on corneal refractive power measurement and surgical planning in cataract patients. Participants were divided into tear film instability (tear film stability level 2) and control (level 0–1) groups based on Keratograph 5M results. Using IOL Master 700, two consecutive measurements were obtained with a 10-min interval. Parameters including standard keratometry (Kf, Ks and K), keratometric corneal astigmatism (KCA), total keratometry (TKf, TKs and TK) and total corneal astigmatism (TCA) were recorded. IOL power was calculated using SRK-T, SRK-T TK, Haigis, Haigis TK, Barrett Universal II, and Barrett Universal II TK formulas. The results showed significantly higher differences between two measurements in Kf, K, KCA, TKf, TK, and TCA, as well as the vector variability of corneal astigmatism in the tear film instability group (all P ​< ​0.05). Of all formulas, only the SRK-T formula displayed significantly higher variability in IOL power calculations in the tear film instability group compared to the control group (P ​< ​0.05). This study highlights that tear film instability can lead to deviations in corneal refractive power and astigmatism measurements, contributing to increased prediction errors in IOL power calculation, particularly with the SRK-T formula.

14 January 2019 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
YJYuanfeng Jiang
Yuanfeng Jiang
SBShaochong Bu
Shaochong Bu
FTFang Tian
Fang Tian
JLJingli Liang
Jingli Liang
TWTiecheng Wang
Tiecheng Wang
XZXiaomin Zhang
Xiaomin Zhang
Purpose. To compare long-term clinical outcomes between patients with bilateral implantation of +3.0 diopter (D) multifocal intraocular lenses (IOLs) and mix and match implantation of +2.5 D and +3.0 D multifocal IOLs. Material and Methods. This retrospective observer-masked cohort study comprised 66 eyes of 33 patients with two different strategies of binocular multifocal IOLs implantation: bilateral +3.0 D (17 patients) (bilateral group) and mix and match +2.5 D and +3.0 D (16 patients) (blended group). Patients were recruited 1 year (±3 months) after second-eye surgery. The primary effectiveness endpoint was binocular uncorrected intermediate visual acuity (UCIVA) at 70 cm. The secondary assessments included binocular visual quality tests and quality-of-vision questionnaire. Results. The blended group showed clinically better UCIVA (0.10 ± 0.07 logMAR) at 70 cm than the bilateral group (0.26 ± 0.09 logMAR) with a difference of 0.16 ± 0.08 logMAR (P<0.001). Similar binocular visual acuities were achieved between the two groups at the near and far distance. The binocular defocus curves showed better performance in the blended group from 50 cm to 1 m. The mean binocular contrast sensitivities under the photopic conditions with or without glare and mesopic condition without glare were clinically better in the blended group. Both the groups reported low rate of visual phenomena, high rate of spectacle independence, and satisfaction. Conclusions. Comparing with bilateral implantation of +3.0 D multifocal IOLs during the cataract surgery, mix and match implantation of +2.5 D and +3.0 D multifocal IOLs provides a wider depth of binocular focus, especially for intermediate distances, and better binocular visual quality.

1 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YJYuanfeng Jiang
Yuanfeng Jiang
YQYing Qin
Ying Qin
SBShaochong Bu
Shaochong Bu
HZHong Zhang
Hong Zhang
XZXiaomin Zhang
Xiaomin Zhang
FTFang Tian
Fang Tian
The aim of the study is to explore the distribution patterns and internal correlations of the morphological parameters of the cornea in patients with age-related cataract. The Pentacam HR was used to measure anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), total corneal astigmatism (TCA) and keratometric corneal astigmatism (KCA). With age, the proportion of with-the-rule (WTR) ACA decreased from 65.31% to 23.63%, while the against-the-rule (ATR) ACA increased from 26.53% to 56.20%. PCA exceeded 0.50 D in 9.14% of eyes, while 76.35% of them were ATR. The magnitude of ACA was positively correlated with PCA in the whole sample, with a more significant correlation in WTR eyes (sr = 0.349, P < 0.001). The vector summation effect of PCA to ACA changed from compensation to augmentation with aging. In 57.53% of WTR eyes, KCA was overestimated by an average of 0.21 ± 0.17 D, while it was underestimated by 0.38 ± 0.27 D in 87.62% of ATR eyes. In conclusion, among age-related cataract patients, ACA and TCA gradually shifted from WTR to ATR with aging, while most PCA remained as ATR. Ignoring the age-related changes and real PCA might cause overestimation of WTR astigmatism and underestimation of ATR astigmatism.