This article presents the control of a three-phase three-wire (3P-3W) dual-stage grid-tied PV-battery storage system using a multi-objective grass-hopper optimization (MOGHO) algorithm. The voltage source converter (VSC) control of the presented system is implemented with adaptive kernel width sixth-order maximum correntropy criteria (AKWSOMCC) and maximum power point tracking (MPPT) control is accomplished using the variable step-size incremental conductance (VSS-InC) technique. The proposed VSC control offers lower mean square error and better accuracy, convergence rate and speed as compared to peer adaptive algorithms, i.e., least mean square (LMS), least mean fourth (LMF), maximum correntropy criteria (MCC), etc. The adaptive Gaussian kernel width is a function of the error signal, which changes to accommodate and filter Gaussian and non-Gaussian noise signals in each iteration. The VSS-InC based MPPT is provided with a MOGHO based modulation factor for better and faster tracking of the maximum power point during changing solar irradiation. Similarly, an optimized gain conventional PI controller regulates the DC bus to improve the power quality, and DC link stability during dynamic conditions. The optimized DC-link generates an accurate loss component of current, which further improves the VSC capability of fundamental load current component extraction. The VSC is designed to perform multi-functional operations, i.e., harmonics elimination, reactive power compensation, load balancing and power balancing at point of common coupling during diverse dynamic conditions. The MOSHO based VSS-InC, and DC bus performance is compared to particle swarm optimization (PSO) and genetic algorithm (GA). The proposed system operates satisfactorily as per IEEE519 standards in the MATLAB simulation environment.
The presented work employs the multiple random feature kernel mean p-power algorithm (MRFKMP) for the voltage source converter (VSC) control of a three-phase four-wire grid-tied dual-stage photovoltaic-hybrid energy storage system (HESS) to achieve multiple objectives during various induced dynamic conditions. The proposed control enables the VSC to accomplish manifold goals, i.e., reactive power compensation, power quality enhancement, load, power balancing at common coupling point and grid voltage balancing during unity power factor mode of operation. The proposed system is scrutinized under steady-state and numerous dynamic states such as irradiation variation, specified power mode, abnormal grid voltage, load, and grid voltage unbalancing. The seamless control facilitates the swift resynchronization of the grid as well as maintaining stability during islanding and re-synchronization operations while satisfying the necessary load requirements. The associated HESS consisting of battery and ultra-capacitor is competent enough in managing the interruptions occurring on the grid, load and photovoltaic side. The DC bus voltage is controlled by the PI controller, which is tuned by the generalized normal distribution algorithm and kept at the desired level during diverse operating conditions. The optimized DC bus generates an accurate loss component of current and further enhances the VSC performance. The proposed system is investigated by simulation and found acceptable as per IEEE 519 standards.
27 July 2022 in IEEE Transactions on Industry Applications
This paper presents a photovoltaic (PV)-battery energy storage (BES) system functioning in both grid-tied and standalone modes while performing multi-functional operations, including reactive power compensation, power balancing, and power quality (PQ) enhancement. The PV-BES system ensures uninterrupted power supply to the critical loads even during seamless transition from grid-tied to islanded mode and vice versa. The incremental conductance (InC) technique controls the boost converter and confirms maximum PV power extraction. The bi-directional converter (BDC) connects BES to the DC bus. The DC bus voltage $( {{\mathbf{V}}_{\mathbf{dc}}} )$ is regulated by a slime mould optimized (SMO) proportional-integral (PI) controller to limit the dynamic state variation and improve stability. The voltage source converter (VSC) is controlled by a minimum kernel risk-sensitive mean p-power loss (MKRSMPL) algorithm during grid-synchronization mode. In contrast, the voltage control algorithm executes islanded control of VSC. The VSC control transition is achieved seamlessly without any significant disturbance at the point of common coupling (PCC). The hardware test results demonstrate that the present system remains stable during dynamic conditions and performs adequately as per the IEEE 519-2014 standard.
This paper presents the stability improvement of the three-phase four-wire (3P-4W) grid-tied PV-hybrid energy storage system (HESS) using chaotic grew wolf optimization (CGWO) for DC bus voltage and AC bus voltage control. The CGWO tuned fractional order proportional–integral (FOPI) controllers reduce the and variations during diverse, dynamic conditions, i.e., sudden irradiation variations, deep voltage sag/swell, etc. The DC bus is responsible for the current injection/extraction control, maximum PV power extraction, bi-directional power flow, dc second-harmonics component elimination, and active power balance. At the point of common coupling (PCC), the AC bus is accountable for bi-directional power flow and active and reactive power control. The two-level voltage source converter (VSC) is controlled by a novel variable step-size incremental least mean square (VSS-ILMS) in zero voltage regulation (ZVR) mode. Due to its varying step size, VSC control is less prone to noise signals offers better stability, improved convergence rate, dc offset rejection, and tracking speed during dynamics, i.e., large oscillations. A battery and ultracapacitor are coupled to the DC link by buck-boost converters in the HESS. To regulate power transit between the DC bus and the grid, the HESS current control technique is designed to shift frequently from charging to discharging stage and vice versa. The novelty of the PV-HESS system lies in CGWO tuned VSS-ILMS control of VSC, which effectively and efficiently filter out the active fundamental constituents of load current and eliminate dc offset from VSC output. The HESS control maintains the DC bus voltage profile by absorbing and delivering energy (during dynamic conditions) rather than curtailing it. The presented system is simulated in a MATLAB/SIMULINK environment. The simulation results in graphical and numerical forms verify the stable and satisfactory operation of the proposed system as per IEEE519 standard.
12 October 2023 in Electric Power Systems Research
The presented system is a three-phase three-wire (3P–3W), seamless, capable, dual-stage PV power generation system without battery storage for rural residential loads to ensure a continuous power supply during the daytime. This system effortlessly shifts from the grid-connected (GC) mode to the standalone (SA) mode when the grid utility is unavailable. During the GC mode, a voltage source converter (VSC) is regulated by the polynomial zero-attracting least mean square (PZA-LMS) algorithm-based current control scheme. During the GC mode, the power balance is achieved at the point of common coupling (PCC) by exchanging active power with the grid, whereas the VSC delivers reactive power. Considering the low efficiency of PV power generation systems, an incremental conductance (InC)-based maximum power point tracking (MPPT) algorithm is necessary for the maximum power extraction out of a PV array. During the unavailability of the grid, the presented system operates in the SA mode, when the load is delivered with PV power only via VSC. Considering the high cost of the battery storage system (BSS), bi-directional converter, and charge control circuitry incurred by rural consumers, they were omitted from the system. Without a BSS, the InC-based MPPT is executed in the derated mode, extracting the PV power to exactly match the load demand. Without derated PV power generation operation, the load may be damaged due to excess PV power flow to the load end or the load may remain underpowered, leading to load shedding or complete disconnection. A synchronous reference frame (SRF)-based voltage control scheme is responsible for the VSC control during the SA operation of the system. The presented system performance was observed and found satisfactory during the irradiation variation, load balancing, islanding, and re-synchronization of the grid. The presented system was found to carry out harmonics suppression and active and reactive power balance at the PCC during both the GC and SA modes. The grid’s total harmonics distortion (THD) levels were shown to be kept below 5% as per the IEEE 519 standard in the GC mode.