Hiromasa Kawana

Prof. Hiromasa Kawana

Kanagawa Dental University
+1
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2021 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
KNKoudai Nagata
Koudai Nagata
KFKei Fuchigami
Kei Fuchigami
RKRyoji Kitami
Ryoji Kitami
YOYurie Okuhama
Yurie Okuhama
KWKana Wakamori
Kana Wakamori
HKHiromasa Kawana
Hiromasa Kawana
Background: In locations where the alveolar bone height is low, such as at the maxillary molars, implant placement can be difficult, or even impossible, without procedures aimed at generating new bone, such as sinus lifts. Various types of bone graft materials are used after a sinus lift. In our study, a three-dimensional image analysis using a volume analyzer was performed to measure and compare the volume of demineralized bovine bone mineral (Bio-Oss®) and carbonate apatite (Cytrans®) after a sinus lift, as well as the amount of bone graft material resorption. Patient data were collected from cone-beam computed tomography images taken before, immediately following, and 6 months after the sinus lift. Using these images, both the volume and amount of resorption of each bone graft material were measured using a three-dimensional image analysis system.Results: The amount of bone resorption in the Bio-Oss®-treated group was 25.2%, whereas that of the Cytrans®-treated group was 14.2%. A significant difference was found between the two groups (P< 0.001).Conclusions: Our findings indicate that the volume of bone resorption was smaller in the Cytrans®-treated group than in the Bio-Oss®-treated group, suggesting that Cytrans® is more promising for successful implant treatments requiring a sinus lift.

23 September 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
KNKoudai Nagata
Koudai Nagata
KFKei Fuchigami
Kei Fuchigami
YOYurie Okuhama
Yurie Okuhama
KWKana Wakamori
Kana Wakamori
HTHayato Tsuruoka
Hayato Tsuruoka
HKHiromasa Kawana
Hiromasa Kawana
Background: The use of intraoral scanners (IOS) has facilitated the use of digital workflows for the fabrication of implant-supported prostheses not only for single missing teeth, but also for multiple missing teeth. However, the clinical application of IOS and computer-aided design/manufacturing (CAD/CAM) in implant-supported prosthodontics remains unclear. This study aimed to compare the accuracy of digital and silicone impressions for single-tooth implants for bounded edentulous spaces and two-unit and three-unit implant-supported fixed dental prostheses for free-end edentulous spaces. Methods: This study enrolled 30 patients (n = 10 for each of the three groups) with an average age of 61.9 years. Conventional silicone-based and digital IOS-based impressions were made for all patients, and the implant superstructures were fabricated. We measured the scan-body misfit and compared the accuracy of the impressions for single-unit, two-unit, and three-unit implant prostheses with a bounded edentulous space by superimposing the standard triangulated language (STL) data obtained from IOS over the STL data of the plaster model used for final prosthesis fabrication. The scan bodies of the superimposed single-molar implant, two-unit implant prosthesis without teeth on the mesial side, two-unit implant prosthesis without teeth on the distal side, three-unit implant prosthesis without teeth on the mesial side, and three-unit implant prosthesis without teeth on the distal side were designated as A, B1, B2, C1, and C2, respectively. The misfit for each scan body was calculated and the accuracies were compared using the Tukey–Kramer method. Results: The average scan-body misfit for conditions A, B1, B2, C1, and C2 was 40.5 ± 18.9, 45.4 ± 13.4, 56.5 ± 9.6, 50.7 ± 14.9, and 80.3 ± 12.4 μm, respectively. Significant differences were observed between the accuracies of A and B2, A and C2, and C1 and C2 (P < 0.001). Conclusions: IOS and CAD/CAM can find clinical applications for implant-supported prostheses of up to three units for a bounded edentulous saddle. The use of IOS could render implant treatment easier, benefiting both the surgeons and patients. Prosthesis maladjustment may lead to peri-implantitis and prosthetic fracture. Therefore, further validation of the accuracy of IOS impressions is required in patients with multiple missing teeth in long-span implant prostheses.

YTYukihiko Takemura
Yukihiko Takemura
KKKanta Kido
Kanta Kido
HKHiromasa Kawana
Hiromasa Kawana
Tatsuo TatsuoTatsuo Tatsuo
Tatsuo Tatsuo
TSTakuro Sanuki
Takuro Sanuki
YMYoshiharu Mukai
Yoshiharu Mukai
Intravenous cannulation is an invasive procedure that causes stress, anxiety, and pain for many patients. A recent animal study found that exposure to green light induced antinociceptive and anxiolytic effects. This study examined whether green color exposure reduced stress, anxiety, and pain during peripheral intravenous cannulation (PIC) for sedation in dental patients. In this controlled clinical trial, 24 patients (mean age 40.9 years) were randomized to wear clear glasses or green-colored glasses for 15 min before PIC on two separate days in a cross-over manner. The primary outcome measures were salivary alpha-amylase (sAA) activity and stress-related hemodynamic changes, and the secondary outcome measures were the visual analog scale anxiety (VAS-A) and pain (VAS-P) scores during PIC. The sAA level in the clear group significantly increased during PIC compared with baseline, but did not increase in the green group. Median VAS-P scores during PIC were lower in the green group than in the clear group (VAS-P, 17.0 vs. 50.0). Green color exposure with glasses significantly reduced stress and pain during PIC without any adverse effects. This simple, safe, and effective method may be useful during painful medical procedures.

10 June 2016 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
HMHidetaka Miyashita
Hidetaka Miyashita
SASeiji Asoda
Seiji Asoda
TSTomoya Soma
Tomoya Soma
KMKanako Munakata
Kanako Munakata
MYMasaki Yazawa
Masaki Yazawa
HKHiromasa Kawana
Hiromasa Kawana
Desmoid-type fibromatosis is defined as an intermediate tumor that rarely occurs in the head and neck of children. There is no doubt as to the value of complete surgical excision for desmoid-type fibromatosis. However, in pediatric patients, surgeons may often be concerned about making a wide excision because of the potential for functional morbidity. Some studies have reported a lack of correlation between margin status and recurrence. Therefore, we discussed our findings with a focus on the state of surgical margins. We report an unusual case of a 9-month-old Japanese girl who prior to presenting at our hospital underwent debulking surgery twice with chemotherapy for desmoid-type fibromatosis of the tongue at another hospital. We performed a partial glossectomy and simultaneous reconstruction with local flap and achieved microscopic complete resection. We also reviewed available literature of pediatric desmoid-type fibromatosis in the head and neck. We described successful treatment for the refractory case of pediatric desmoid-type fibromatosis. The review results showed that some microscopic incomplete resections of tumors in pediatric patients with desmoid-type fibromatosis tended to be acceptable with surgical treatment.

14 July 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
YOYurie Okuhama
Yurie Okuhama
KNKoudai Nagata
Koudai Nagata
HKHyunjin Kim
Hyunjin Kim
HTHayato Tsuruoka
Hayato Tsuruoka
MAMihoko Atsumi
Mihoko Atsumi
HKHiromasa Kawana
Hiromasa Kawana
Background: Several devices have been developed to measure implant-bone stability as an indicator of successful implant treatment; these include Osstell®, which measures the implant stability quotient (ISQ), and the more recent AnyCheck®, which relies on percussion for the implant stability test (IST). These devices make it possible to measure implant stability. However, no studies have compared the performance of AnyCheck® and Osstell® (i.e., IST and ISQ values) in clinical practice. Therefore, this study aimed to determine the correlation between primary and secondary implant stability using the Osstell® and AnyCheck® devices. Methods: Ten patients (7 women; age [mean ± standard deviation]: 49.1 ± 13.3 years) with partially edentulous jaws who received a total of 15 implants were included. IST (AnyCheck®) and ISQ (Osstell®) values were measured immediately after implantation and at 1, 2, 3, 4, and 6 weeks post-implantation. Each measurement was performed three times, and the average value was used as the result. The correlation between measurements obtained using the two devices was determined using Spearman's rank correlation coefficient. Results: The IST values ranged from 79.1 ± 2.87 to 82.4 ± 2.65. The ISQ values ranged from 76.0 ± 2.8 to 80.2 ± 2.35. Spearman's rank correlation coefficient was r = 0.64 immediately after implantation, r = 0.29 at 1 week, r = 0.68 at 2 weeks, r = 0.53 at 3 weeks, r = 0.68 at 4 weeks, and r = 0.56 at 6 weeks. A positive correlation was found in all cases, except at week 1 when the correlation was weak; the IST and ISQ values decreased the most during the first postoperative week and increased during the second week. The IST values were also slightly higher at all measurement points. Conclusion: The ability to assess implant stability without removing the abutment during healing is essential for determining the timing of loading without the risk of bone resorption. The results of this study suggest that AnyCheck® is useful for determining primary and secondary implant stability.

9 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TITomoki Itamiya
Tomoki Itamiya
MTMasahiro To
Masahiro To
TOTakeshi Oguchi
Takeshi Oguchi
SFShinya Fuchida
Shinya Fuchida
MMMasato Matsuo
Masato Matsuo
KKKatsuhiko Kimoto
Katsuhiko Kimoto
Several efforts have been made to use virtual reality (VR) and augmented reality (AR) for medical and dental education and surgical support. The current methods still require users to wear devices such as a head-mounted display (HMD) and smart glasses, which pose challenges in hygiene management and long-term use. Additionally, it is necessary to measure the user’s inter-pupillary distance and to reflect it in the device settings each time to accurately display 3D images. This setting is difficult for daily use. We developed and implemented a novel anatomy education method using a spatial reality display capable of stereoscopic viewing with the naked eye without an HMD or smart glasses. In this study, we developed two new applications: (1) a head and neck anatomy education application, which can display 3D-CG models of the skeleton and blood vessels of the head and neck region using 3D human body data available free of charge from public research institutes, and (2) a DICOM image autostereoscopic viewer, which can automatically convert 2D CT/MRI/CBCT image data into 3D-CG models. In total, 104 students at the School of Dentistry experienced and evaluated the system, and the results suggest its usefulness. A stereoscopic display without a head-mounted display is highly useful and promising for anatomy education.