Weixing Guo

Dr. Weixing Guo

President and Principal Hydrogeologist/Modeler, Groundwater Tek, Inc., Naples, FL; Courtesy Faculty, Florida Gulf Coast University, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2014 in Environmental Earth Sciences
Verified
Journal Article
Closed access
PDF file
Weixing GuoWeixing Guo
Weixing Guo
KCKapo Coulibaly
Kapo Coulibaly
RMRobert G. Maliva
Robert G. Maliva

11 October 2017 in Water
Verified
Journal Article
Open access
PDF file
Thomas MissimerThomas Missimer
Thomas Missimer
Weixing GuoWeixing Guo
Weixing Guo
JWJohn Woolschlager
John Woolschlager
Robert MalivaRobert Maliva
Robert Maliva
Managed Aquifer Recharge (MAR) systems can be used within the context of integrated water management to create solutions to multiple objectives. Southwestern Florida is faced with severe environmental problems associated with the wet season discharge of excessive quantities of surface water containing high concentrations of nutrients into the Caloosahatchee River Estuary and a future water supply shortage. A 150,000 m3/day MAR system is proposed as an economic solution to solve part of the environmental and water supply issues. Groundwater modeling has demonstrated that the injection of about 150,000 m3/day into the Avon Park High Permeable Zone will result in the creation of a 1000 m wide plume of fresh and brackish-water (due to mixing) extending across the water short area over a 10-year period. The operational cost of the MAR injection system would be less than $0.106/m3 and the environmental benefits would alone more than cover this cost in the long term. In addition, the future unit water supply cost to the consumer would be reduced from $1 to $1.25/m3 to $0.45 to $0.65/m3.

15 July 2021 in Water
Verified
Journal Article
Open access
PDF file
QAQuillan Arico
Quillan Arico
Zoie KassisZoie Kassis
Zoie Kassis
Robert MalivaRobert Maliva
Robert Maliva
Weixing GuoWeixing Guo
Weixing Guo
WMW. Scott Manahan
W. Scott Manahan
Thomas MissimerThomas Missimer
Thomas Missimer
Brackish-water reverse osmosis (BWRO) desalination facilities are designed to treat feedwater within a fixed range in salinity. If the salinity and ion concentrations of the feedwater rises above the maximum design concentrations, then the plant may ultimately fail. BWRO plants typically use groundwater as a feedwater source. Prior to the process design, a detailed groundwater assessment is made to characterize the source aquifer system and to develop a solute-transport model that is used to project the changes in water quality over the expected useful life of the facility. Solute transport-modeling performed for the Collier County (Florida) South BWRO facility, which was designed to produce 30,303 m3/d with an expansion to 75,758 m3/d, used an aquifer system conceptual model that assumed upwards migration over time of brackish waters with higher salinities into the production zones. This conceptual model is typical of how most BWRO systems developed in the United States operate. The original solute transport model predicted a range of increases in dissolved chloride concentrations over a 20-year period from a low of 5 mg/L/yr, a mid-range of 35 mg/L/yr, and a high range of 85 mg/L/yr. Actual data collected over a 11- to 13.5-year period showed that the dissolved chloride concentration average of the feed water decreased by 16 mg/L/yr. The original conceptual model was found to be inaccurate in that it suggested an upwards recharging system, whereas downward leakage (or perhaps lateral migration) of fresher water appears to be occurring in the system. This is an example of a long-term solute-transport model audit, which is rarely performed, in which a new conceptual model was found to be applicable to an aquifer system used to feed a BWRO facility.

20 November 2021 in Water
Verified
Journal Article
Open access
PDF file
Weixing GuoWeixing Guo
Weixing Guo
Variable density flow (VDF) modeling is a valuable tool for assessing the potential impacts of global climate change and sea level rise on coastal aquifers. When using any of these modeling tools, a quantitative relationship is needed to compute the fluid density from salt concentration. A full understanding of the relationship between fluid density and solute concentration and the correct implementation of the equation of state are critical for variable density modeling. The works of Baxter and his colleagues in the early 20th century showed that fluid density could be linearly correlated to salt concentrations. A constant density slope of 0.7 is often assumed and applied. The assumption is reasonable when the salinity is less than 100‰. The density slope can also be defined from chloride concentration data with the assumption of a constant ratio (55%) between chloride and total dissolved solids (TDS). Field data from central Florida indicate that the chloride/TDS ratio can be as low as 5%. Therefore, TDS is the preferred water quality data for fluid density determination in variable density modeling. Other issues with density slope are also discussed, and some commonly used values of density slope are provided in this technical note.

7 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Zoie KassisZoie Kassis
Zoie Kassis
Weixing GuoWeixing Guo
Weixing Guo
Robert MalivaRobert Maliva
Robert Maliva
WMW. Scott Manahan
W. Scott Manahan
RRRachel Rose Rotz
Rachel Rose Rotz
Thomas MissimerThomas Missimer
Thomas Missimer
Brackish water reverse osmosis (BWRO) desalination of groundwater is believed to be a sustainable method of providing municipal utilities with a high-quality supply in regions where freshwater sources are stressed and not sustainable. A key aspect of water management is the ability to evaluate an aquifer containing brackish water to ascertain future pumping-induced water quality changes and their impacts on the facility operation and economics. The city of Hialeah, Florida, has operated a BWRO facility for the last 9 years. The facility has a maximum design capacity of about 88,000 m3/d but is currently operating at about 33,000 m3/d. The facility was designed to treat water with a TDS of up to 10,000 mg/L. A detailed hydrogeologic investigation, including groundwater solute-transport modeling, suggested that the salinity of the source water would remain under 10,000 mg/L of TDS during the 30-year life expectancy of the facility. However, after 9 years of operation, it was found that the rate of salinity increase was much higher than predicted (27.5%), at the low rate of 33,000 m3/d. If the faculty was operated at the maximum capacity, the ability of the plant to treat the source water might be between 5 and 10 years. The conceptual model used to guide the solute transport modeling was not accurate for this site because it did not incorporate the apparent enhanced leakance through the basal confining unit below the aquifer. The greater leakance was likely caused by undetected, irregularly distributed fracturing of the underlying confining dolostones. The facility will require a major redesign to upgrade the process to be able to treat seawater at a TDS significantly above 10,000 mg/L in the future, should that occur. While the change will be costly, with a high capital cost to change the process, increased energy consumption, and overall higher water treatment cost, it is still more sustainable and has less environmental impact compared to other alternatives (e.g., treating tidal sources of seawater). The use of electricity from nuclear or solar generation could mitigate the environmental impacts of higher power consumption.

1 February 2014 in Opflow
Verified
Journal Article
Closed access
RMRobert Maliva
Robert Maliva
WMWilliam Scott Manahan
William Scott Manahan
Weixing GuoWeixing Guo
Weixing Guo