4 April 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
XQXiao Qin
Xiao Qin
LTLei Tian
Lei Tian
HZHaixia Zhang
Haixia Zhang
XCXinyan Chen
Xinyan Chen
LLLin Li
Lin Li
Corneal biomechanical properties are important for the diagnosis of corneal diseases, individualized design and prognosis of corneal surgery. Clinical available devices such as Ocular Response Analyzer (ORA) and Corneal Visualization Scheimpflug Technology (Corvis ST) can provide corneal biomechanics related parameters, while corneal elastic modulus cannot be extracted directly from them at present. The aim of this study is to suggest a method to determine corneal elastic modulus based on the results of Corvis ST test according to Reissner’s theory on the relation between stress and small displacement in shallow spherical shell. Five rabbits (10 eyes) and 10 healthy humans (20 eyes) were measured with Corvis ST to obtain the normal range of corneal elastic modulus. Results showed Corneal elastic modulus of rabbit was 0.16 MPa to 0.35 MPa, human corneal elastic modulus was 0.16–0.30 MPa. Rabbit corneas were also measured at different intraocular pressures (IOP), and results showed corneal elastic modulus, first applanation time (A1T) and stiffness parameter (SP-A1) were positively correlated with IOP. Deformation amplitude (DA), the second applanations time (A2T), and peak distance (PD) were negatively correlated with IOP. Finite element method was used to simulate the Corvis measurements according to the calculated elastic modulus and the simulated corneal apical displacements were agreement with experimental results in general. The method to determine corneal elastic modulus based on Corvis test according to the relationship between force and displacements of shallow spherical shell is convenient and effective.

3 January 2021 in International Ophthalmology
Verified
Journal Article
Open access
PDF file
HZHui Zhang
Hui Zhang
LTLei Tian
Lei Tian
LGLili Guo
Lili Guo
XQXiao Qin
Xiao Qin
DZDi Zhang
Di Zhang
HZHaixia Zhang
Haixia Zhang
Objective: To more comprehensively evaluate the ability of the parameters reflecting the morphological and biomechanical properties of the cornea to distinguish clinical keratoconus (CKC) and forme fruste keratoconus (FFKC) from normal. Methods: Normal eyes (n = 50), CKC (n = 45) and FFKC (n = 15) were analyzed using Pentacam, Corvis ST and ORA. Stepwise logistic regression of all parameters was performed to obtain the optimal combination model capable of distinguishing CKC, FFKC from normal, named SLR1 and SLR2, respectively. Receiver operating characteristic (ROC) curves were applied to determine the predictive accuracy of the parameters and the two combination models, as described by the area under the curve (AUC). AUCs were compared using the DeLong method. Results: The SLR1 model included only the TBI output by Pentacam, while the SLR2 model included the morphological parameter F.Ele.Th and two parameters from the Corvis ST, HC DfA and SP-A1. The majority of the parameters had sufficient strength to differentiate the CKC from normal corneas, even the seven separate parameters and the SLR1 model had a discrimination efficiency of 100%. The predictive accuracy of the parameters was moderate for FFKC, and the SLR2 model (0.965) presented an excellent AUC, followed by TBI, F.Ele.Th and BAD-D. Conclusion: The F.Ele.Th from Pentacam was the most sensitive morphological parameter for FFKC, and the combination of F.Ele.Th, HC DfA and SP-A1 made the diagnosis of FFKC more efficient. The CRF and CH output by ORA did not improve the combined diagnosis, despite the corneal combination of morphological and biomechanical properties that optimized the diagnosis of FFKC.

10 January 2020 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
HZHui Zhang
Hui Zhang
ZSZhengtao Sun
Zhengtao Sun
LLLin Li
Lin Li
RSRan Sun
Ran Sun
HZHaixia Zhang
Haixia Zhang
Background: Accurate measurement of intraocular pressure (IOP) after corneal refractive surgery is of great significance to clinic, and comparisons among various IOP measuring instruments are not rare, but there is a lack of unified analysis. Although Goldmann Applanation Tonometer (GAT) is currently the internationally recognized gold standard for IOP measurement, its results are severely affected by central corneal thickness (CCT). Ocular Response Analyzer (ORA) takes certain biomechanical properties of cornea into account and is supposed to be less dependent of CCT. In this study, we conducted the meta-analysis to systematically assess the differences and similarities of IOP values measured by ORA and GAT in patients after corneal refractive surgery from the perspective of evidence-based medicine. Methods: The authors searched electronic databases (MEDLINE, EMBASE, Web of science, Cochrane library and Chinese electronic databases of CNKI and Wanfang) from Jan. 2005 to Jan. 2019, studies describing IOP comparisons measured by GAT and ORA after corneal refractive surgery were included. Quality assessment, subgroup analysis, meta-regression analysis and publication bias analysis were applied in succession. Results: Among the 273 literatures initially retrieved, 8 literatures (13 groups of data) with a total of 724 eyes were included in the meta-analysis, and all of which were English literatures. In the pooled analysis, the weighted mean difference (WMD) between IOPcc and IOPGAT was 2.67 mmHg (95% CI: 2.20~3.14 mmHg, p < 0.0001), the WMD between IOPg and IOPGAT was − 0.27 mmHg (95% CI: − 0.70~0.16 mmHg, p = 0.2174). In the subgroup analysis of postoperative IOPcc and IOPGAT, the heterogeneity among the data on surgical procedure was zero, while the heterogeneity of other subgroups was still more than 50%. The comparison of the mean difference of pre- and post-operative IOP (∆IOP) was: mean-∆IOPg > mean-∆IOPGAT > mean-∆IOPcc. Conclusions: IOPcc, which is less dependent on CCT, may be more close to the true IOP after corneal refractive surgery compared with IOPg and IOPGAT, and the recovery of IOPcc after corneal surface refractive surgery may be more stable than that after lamellar refractive surgery.

16 July 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
XQXiao Qin
Xiao Qin
MYMengyao Yu
Mengyao Yu
HZHaixia Zhang
Haixia Zhang
XCXinyan Chen
Xinyan Chen
LLLin Li
Lin Li
Purpose. Ocular Response Analyzer (ORA) is one of the most widely used devices in clinic, while the mechanical interpretations of parameters obtained from ORA have not been understood completely. The aim of this research is to explore the mechanical interpretation of ORA parameters. Methods. Rabbits aged 3-24 months were measured with ORA in vivo and corneal strips uniaxial tensile tests to get ORA parameters and corneal biomechanical parameters (corneal elastic modulus, relaxation time, and relaxation limit). The mechanical interpretation of ORA parameters was cognized preliminarily by analyzing the correlation between ORA parameters and corneal biomechanical parameters. On the other hand, finite element method was applied to simulate ORA measurements with different corneal biomechanical parameters to obtain quantitative relationship between ORA parameters and corneal biomechanical parameters further. Results. Biomechanical experimental results showed that Corneal Resistance Factor (CRF) was correlated with corneal elastic modulus and relaxation limit significantly, while the significant correlations between Corneal Hysteresis (CH) and corneal biomechanical parameters were not observed. Results of finite element analysis showed that both CH and CRF were correlated with corneal elastic modulus, relaxation limit, and relaxation time significantly. Besides, corneal elastic modulus was positively correlated with upslop1 and upslop2 and negatively correlated with w2. Conclusions. For all ORA parameters, CH, CRF, the upslope, and the width of the peaks are parameters which may reflect corneal elastic properties. It is viable to cognize mechanical interpretation of ORA parameters by the comparisons of the data from ORA and biomechanical tests of rabbits with different ages and the simulations of ORA based on finite element methods. Further studies are needed to confirm the mechanical interpretation.

1 January 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
HZHaixia Zhang
Haixia Zhang
XQXiao Qin
Xiao Qin
XCXiaomeng Cao
Xiaomeng Cao
DZDi Zhang
Di Zhang
LLLin Li
Lin Li
Purpose. To study the variations in corneal clinical biomechanical parameters (CCBP) and corneal geometrical parameters of rabbit in relation to age. Methods. Rabbits aged 3, 7, 12, 18, and 24 months were enrolled. Each eye of the rabbits was tested with Ocular Response Analyzer (ORA), Optical Coherence Tomography (OCT), and Pachymeter to obtain the intraocular pressure (IOP): Goldmann-correlated IOP (IOPg) and Corneal Compensated Intraocular Pressure (IOPcc); CCBP: Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF); corneal geometric parameters: corneal curvature radius (CCR) and central corneal thickness (CCT). Results. The IOP of the rabbits changes slightly from 3 to 7 months of age, while it significantly decreases from 7 to 18 months of age and increases from 18 to 24 months of age; CH and CRF decrease with the increase of age; CCT increases from 7 to 18 months and decreases from 3 to 7 months of age and from 18 to 24 months of age; CCR presents an upward trend from 3 to 18 months and a significant decrease between 18 and 24 months of age. Conclusion. CH and CRF are negatively correlated with age. CCT and CCR are positively correlated with age.

11 January 2018 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
HZHaixia Zhang
Haixia Zhang
MKMuhammad Ahmad Khan
Muhammad Ahmad Khan
DZDi Zhang
Di Zhang
XQXiao Qin
Xiao Qin
DLDing Lin
Ding Lin
LLLin Li
Lin Li
Background. The changes in corneal biomechanical properties after LASIK remain an unknown but important topic for surgical design and prognostic evaluation. This study aims to observe the postoperative corneal biomechanical properties one month after LASIK with amount of corneal cutting (ACC) greater than 50% of the central corneal thickness (CCT). Methods. FS-LASIK was performed in 10 left rabbit eyes with ACC being 60% (L60) and 65% (L65) of the CCT, while the right eyes (R) were the control. After 4 weeks, rabbits were executed and corneal strip samples were prepared for uniaxial tensile tests. Results. At the same strain, the stresses of L65 and L60 were larger than those of R. The elastic moduli of L60 and L65 were larger than those of R when the stress was 0.02 MPa, while they began to be less than those of R when stress exceeds the low-stress region. After 10 s relaxation, the stress of specimens L65, L60, and R increased in turn. Conclusion. The elastic moduli of the cornea after FS-LASIK with ACC greater than 50% of the CCT do not become less under normal rabbit IOP. The limit stress grows with the rise of ACC when relaxation becomes stable.