The purpose of this study was to compare the correlation and agreement between AS derived from either an energy-integrating detector CT (EID-CT) or a photon-counting detector CT (PCD-CT). Reproducibility was also compared. In total, 26 calcified coronary lesions (from five cadaveric hearts) were identified for inclusion. The hearts were positioned in a chest phantom and scanned in both an EID-CT and a prototype PCD-CT. The EID-CT and PCD-CT acquisition and reconstruction parameters were matched. To evaluate the reproducibility, the phantom was manually repositioned, and an additional scan was performed using both methods. The EID-CT reconstructions were performed using the dedicated calcium score kernel Sa36. The PCD-CT reconstructions were performed with a vendor-recommended kernel (Qr36). Several monoenergetic energy levels (50–150 keV) were evaluated to find the closest match with the EID-CT scans. A semi-automatic evaluation of calcium score was performed on a post-processing multimodality workplace. The best match with Sa36 was PCD-CT Qr36 images, at a monoenergetic level of 72 keV. Statistical analyses showed excellent correlation and agreement. The correlation and agreement with regards to the Agatston score (AS) between the two methods, for each position as well as between the two positions for each method, were assessed with the Spearman´s rank correlation. The correlation coefficient, rho, was 0.98 and 0.97 respectively 0.99 and 0.98. The corresponding agreements were investigated by means of Bland–Altman plots. High correlation and agreement was observed between the AS derived from the EID-CT and a PCD-CT. Both methods also demonstrated excellent reproducibility.
27 February 2013 in Magnetic Resonance in Medicine
Purpose: Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture.Methods: Atherosclerotic plaques from 10 patients (three asymptomatic and seven symptomatic) were investigated. Plaque vulnerability was classified using ultrasound and immunohistochemistry and correlated to Fe(III) measured by electron paramagnetic resonance spectroscopy.Results: Large intra‐plaque Fe(III) variations were found. Plaques from symptomatic patients had a higher Fe(III) concentration as compared with asymptomatic plaques (0.36 ± 0.21 vs. 0.06 ± 0.04 nmol Fe(III)/mg tissue, P < 0.05, in sections adjoining narrowest part of the plaques). All but one plaque from symptomatic patients showed signs of cap rupture. No plaque from asymptomatic patients showed signs of cap rupture. There was a significant increase in cap macrophages in plaques from symptomatic patients compared with asymptomatic patients (31 ± 11% vs. 2.3 ± 2.3%, P < 0.01).Conclusion: Fe(III) distribution varies substantially within atherosclerotic plaques. Plaques from symptomatic patients had significantly higher concentrations of Fe(III), signs of cap rupture and increased cap macrophage activity. Magn Reson Med 71:885–892, 2014.
Machine learning (ML) is rapidly progressing in many scientific fields, including medicine.1 For breast cancer, we are beholding the emergence of commercially available artificial intelligence (AI) systems for breast cancer detection (AI-CADe),2–8 triaging, diagnosis, and risk assessment.9 If the performance of such systems proves to be accurate and robust in a clinical setting, incorporating them into the screening process can significantly benefit both the hospital and the screening participants. The most common use case, AI-CADe, would reduce radiologist workload and potentially reduce the rate of missed cancers.10 Some challenges remain despite the potential impact of adopting these technologies in the screening process. Collectively these challenges are known as the AI translational gap, which is currently under special investigation by the Federal Drug Administration in the United States of America (USA).11
Objective: To evaluate the cost-effectiveness of AI-assisted digital mammography (AI-DM) compared to conventional biennial breast cancer digital mammography screening (cDM) with double reading of screening mammograms, and to investigate the change in cost-effectiveness based on four different sub-strategies of AI-DM. Materials and methods: A decision-analytic state-transition Markov model was used to analyse the decision of whether to use cDM or AI-DM in breast cancer screening. In this Markov model, one-year cycles were used, and the analysis was performed from a healthcare perspective with a lifetime horizon. In the model, we analysed 1000 hypothetical individuals attending mammography screenings assessed with AI-DM compared with 1000 hypothetical individuals assessed with cDM. Results: The total costs, including both screening-related costs and breast cancer-related costs, were €3,468,967 and €3,528,288 for AI-DM and cDM, respectively. AI-DM resulted in a cost saving of €59,320 compared to cDM. Per 1000 individuals, AI-DM gained 10.8 quality-adjusted life years (QALYs) compared to cDM. Gained QALYs at a lower cost means that the AI-DM screening strategy was dominant compared to cDM. Break-even occurred at the second screening at age 42 years. Conclusion: This analysis showed that AI-assisted mammography for biennial breast cancer screening in a Swedish population of women aged 40–74 years is a cost-saving strategy compared to a conventional strategy using double human screen reading. Further clinical studies are needed, as scenario analyses showed that other strategies, more dependent on AI, are also cost-saving. Key Points: QuestionTo evaluate the cost-effectiveness of AI-DM in comparison to conventional biennial breast cDM screening . FindingsAI-DM is cost-effective, and the break-even point occurred at the second screening at age 42 years . Clinical relevanceThe implementation of AI is clearly cost-effective as it reduces the total cost for the healthcare system and simultaneously results in a gain in QALYs . Graphical
Inactin is a long lasting anesthetic agent commonly used in rat studies, but is also shown to exert physiological effects such as reducing renal blood flow, glomerular filtration rate and depressing tubular transport capacity. The effect of inactin on isolated kidney mitochondria is unknown and may be important when studying related topics in anaesthetized animals. The aim of this study was to determine whether inactin exerts effects on mitochondrial function and production of reactive oxygen species. Kidney mitochondrial function and production of reactive oxygen after acutely (5 min) or longer (1.5 hour) anesthetizing rats with inactin was evaluated using high-resolution respirometry. The results demonstrate that inactin significantly improves respiratory control ratio, inhibits complex I in the mitochondrial respiratory chain, reduce both unregulated proton leak and time dependently reduce the regulated proton leak via uncoupling protein-2 and adenine nucleotide translocase. Inactin also contributes to increased mitochondrial hydrogen peroxide production. In conclusion, inactin exerts persistent effects on mitochondrial function and these profound effects on mitochondrial function should to be considered when studying mitochondria isolated from animals anesthesized with inactin.