Cheng-Sheng Huang

Prof. Cheng-Sheng Huang

National Chiao Tung University , Hsinchu · Department of Mechanical Engineering

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2017 in The Analyst
Verified
Journal Article
Closed access
PDF file
MTMeng-Zhe Tsai
Meng-Zhe Tsai
CHChan-Te Hsiung
Chan-Te Hsiung
YCYang Chen
Yang Chen
CHCheng-Sheng Huang
Cheng-Sheng Huang
HHHsin-Yun Hsu
Hsin-Yun Hsu
PHPei-Ying Hsieh
Pei-Ying Hsieh
We demonstrate the detection of C-creative protein (CRP) from whole blood samples without sample pretreatment by using a lab-on-a-chip system consisting of a microfluidic chip and a label-free biosensor. The microfluidic chip includes an array of microposts for filtering blood cells and allows only plasma to flow through and reach the guided-mode resonance (GMR) biosensor for real-time monitoring. The developed GMR sensor can achieve a bulk sensitivity of 186 nm RIU−1, which supports a limit of detection of 3.2 ng mL−1 for recombinant CRP spiked in human serum. The results are comparable with those obtained using enzyme-linked immunosorbent assay. In addition, we demonstrate the efficacy of filtration of blood cells using microposts and simultaneous measurement of CRP concentration using a GMR sensor by using whole blood and plasma samples.

3 February 2016 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
HLHsin-An Lin
Hsin-An Lin
CHCheng-Sheng Huang
Cheng-Sheng Huang
In this letter, we fabricated and characterized a linear variable filter based on a guided-mode resonance filter (GMRF) with gradient grating periods. The GMRF was first fabricated through nanoreplica molding on a plastic substrate, which was followed by the deposition of a thin TiO 2 film. The grating periods of the GMRF vary from 250 to 550 nm with a 2-nm increment in each period consisting of 100 cycles. The results show that a 6-mm-long GMRF has a filtering range of 506-915 nm.

29 April 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
YTYi-Kai Tu
Yi-Kai Tu
MTMeng-Zhe Tsai
Meng-Zhe Tsai
ILI-Chin Lee
I-Chin Lee
HHHsin-Yun Hsu
Hsin-Yun Hsu
CHCheng-Sheng Huang
Cheng-Sheng Huang
The integration of a label-free biosensor of a guided-mode resonance filter and a microfluidic channel with a micropost filter.

15 January 2018 in IEEE Photonics Journal
Verified
Journal Article
Open access
HHHsin-Yun Hsu
Hsin-Yun Hsu
YLYi-Hsuan Lan
Yi-Hsuan Lan
CHCheng-Sheng Huang
Cheng-Sheng Huang
This paper reports a compact spectrometer based on a guided-mode resonance (GMR) filter mounted on a linear charge-coupled device (CCD). The GMR is specially designed to exhibit gradient grating periods laterally to ensure that the GMR functions as a linear variable bandstop filter. Each period corresponds to a resonant wavelength such that this wavelength is reflected back at its corresponding resonant period and transmitted to all other periods. Consequently, when a resonant wavelength is incident on the gradient grating period (GGP)-GMR attached to a linear CCD, the CCD pixel underneath its resonant period receives the minimum intensity and the other pixels receive higher intensities. In terms of the wavelength range of interest, by scanning a single wavelength at a time, a transmission efficiency matrix that contains the transmission efficiency of each wavelength at each pixel can be established. An unknown incident spectrum can be reconstructed using the established transmission efficiency matrix and the intensity measured using the CCD. In this study, a GGP-GMR spectrometer less than 3 mm long that can achieve a wavelength detection range of 200 nm was demonstrated to reconstruct various incident spectra, including a single wavelength of light with a resolution of 0.5 nm, single wavelength of light with varying intensity levels, and dual incident light sources.

7 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JYJia-Ming Yang
Jia-Ming Yang
NYNien-Zu Yang
Nien-Zu Yang
CCCheng-Hao Chen
Cheng-Hao Chen
CHCheng-Sheng Huang
Cheng-Sheng Huang
Portable systems for detecting biomolecules have attracted considerable attention, owing to the demand for point-of-care testing applications. This has led to the development of lab-on-a-chip (LOC) devices. However, most LOCs are developed with a focus on automation and preprocessing of samples; fluorescence measurement, which requires additional off-chip detection instruments, remains the main detection method in conventional assays. By incorporating optical biosensors into LOCs, the biosensing system can be simplified and miniaturized. However, many optical sensors require an additional coupling device, such as a grating or prism, which complicates the optical path design of the system. In this study, we propose a new type of biosensor based on gradient waveguide thickness guided-mode resonance (GWT-GMR), which allows for the conversion of spectral information into spatial information such that the output signal can be recorded on a charge-coupled device for further analysis without any additional dispersive elements. A two-channel microfluidic chip with embedded GWT-GMRs was developed to detect two model assays in a buffer solution: albumin and creatinine. The results indicated that the limit of detection for albumin was 2.92 μg/mL for the concentration range of 0.8–500 μg/mL investigated in this study, and that for creatinine it was 12.05 μg/mL for the concentration range of 1–10,000 μg/mL. These results indicated that the proposed GWT-GMR sensor is suitable for use in clinical applications. Owing to its simple readout and optical path design, the GWT-GMR is considered ideal for integration with smartphones or as miniaturized displays in handheld devices, which could prove beneficial for future point-of-care applications.

4 January 2019 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
CHChan-Te Hsiung
Chan-Te Hsiung
CHCheng-Sheng Huang
Cheng-Sheng Huang