Maryam Tabrizian

Dr. Maryam Tabrizian

James McGill Professor, Professor of Biomedical Engineering, Professor of Bioengineering, Professor of Experimental Surgery, Department of Biomedical Engineering, Faculty of Medicine/Faculty of Dentistry, Duff Medical Science Building, 3775 University Str
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AFAmir M. Foudeh
Amir M. Foudeh
TDTohid Fatanat Didar
Tohid Fatanat Didar
TVTeodor Veres
Teodor Veres
MTMaryam Tabrizian
Maryam Tabrizian
Effective pathogen detection is an essential prerequisite for the prevention and treatment of infectious diseases. Despite recent advances in biosensors, infectious diseases remain a major cause of illnesses and mortality throughout the world. For instance in developing countries, infectious diseases account for over half of the mortality rate. Pathogen detection platforms provide a fundamental tool in different fields including clinical diagnostics, pathology, drug discovery, clinical research, disease outbreaks, and food safety. Microfluidic lab-on-a-chip (LOC) devices offer many advantages for pathogen detection such as miniaturization, small sample volume, portability, rapid detection time and point-of-care diagnosis. This review paper outlines recent microfluidic based devices and LOC design strategies for pathogen detection with the main focus on the integration of different techniques that led to the development of sample-to-result devices. Several examples of recently developed devices are presented along with respective advantages and limitations of each design. Progresses made in biomarkers, sample preparation, amplification and fluid handling techniques using microfluidic platforms are also covered and strategies for multiplexing and high-throughput analysis, as well as point-of-care diagnosis, are discussed.

3 September 2022 in Biomaterials
Verified
Journal Article
Closed access
MBMika Brown
Mika Brown
JLJianyu Li
Jianyu Li
CMChristopher Moraes
Christopher Moraes
MTMaryam Tabrizian
Maryam Tabrizian
NLNicole Y.K. Li-Jessen
Nicole Y.K. Li-Jessen

19 August 2009 in Biotechnology Letters
Verified
Journal Article
Closed access
PDF file
ZHZiyad Haidar
Ziyad Haidar
RHReggie C. Hamdy
Reggie C. Hamdy
MTMaryam Tabrizian
Maryam Tabrizian

1 December 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LMLidija Malic
Lidija Malic
DBDaniel Brassard
Daniel Brassard
TVTeodor Veres
Teodor Veres
MTMaryam Tabrizian
Maryam Tabrizian
The ambition of lab-on-a-chip (LOC) systems to achieve chip-level integration of a complete analytical process capable of performing a complex set of biomedical protocols is hindered by the absence of standard fluidic components able to be assembled. As a result, most microfluidic platforms built to date are highly specialized and designed to fulfill the requirements of a single particular application within a limited set of operations. Electrowetting-on-dielectric (EWOD) digital microfluidic technology has been recently introduced as a new methodology in the quest for LOC systems. Herein, unit volume droplets are manipulated along electrode arrays, allowing a microfluidic function to be reduced to a set of basic operations. The highly reprogrammable architecture of these systems can satisfy the needs of a diverse set of biochemical assays and ensure reconfigurability, flexibility and portability between different categories of applications and requirements. While important progress was made over past years in the fabrication, miniaturization and function programming of the basic EWOD fluidic operations, the success of this technology will in great part depend on the ability of researchers to couple or integrate digital microfluidics to detection approaches that can make the system competitive for LOC applications. The detection techniques should be able to circumvent the limitations of hydrophobic surfaces and exploit the advantages of the array format, high droplet transport speeds and rapid mixing schemes. This review provides an in-depth look at recent developments for the coupling and integration of detection techniques with digital microfluidic platforms for bio-chemical applications.

29 September 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
TDTohid Fatanat Didar
Tohid Fatanat Didar
MTMaryam Tabrizian
Maryam Tabrizian
The detection, isolation and sorting of cells are important tools in both clinical diagnostics and fundamental research. Advances in microfluidic cell sorting devices have enabled scientists to attain improved separation with comparative ease and considerable time savings. Despite the great potential of Lab-on-Chip cell sorting devices for targeting cells with desired specificity and selectivity, this field of research remains unexploited. The challenge resides in the detection techniques which has to be specific, fast, cost-effective, and implementable within the fabrication limitations of microchips. Adhesion-based microfluidic devices seem to be a reliable solution compared to the sophisticated detection techniques used in other microfluidic cell sorting systems. It provides the specificity in detection, label-free separation without requirement for a preprocessing step, and the possibility of targeting rare cell types. This review elaborates on recent advances in adhesion-based microfluidic devices for sorting, detection and enrichment of different cell lines, with a particular focus on selective adhesion of desired cells on surfaces modified with ligands specific to target cells. The effect of shear stress on cell adhesion in flow conditions is also discussed. Recently published applications of specific adhesive ligands and surface functionalization methods have been presented to further elucidate the advances in cell adhesive microfluidic devices.