Kyriaki Manoli

Kyriaki Manoli


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2013 in Chemical Society Reviews
Verified
Journal Article
Closed access
PDF file
Luisa TorsiLuisa Torsi
Luisa Torsi
MMMaria Magliulo
Maria Magliulo
KMKyriaki Manoli
Kyriaki Manoli
Gerardo PalazzoGerardo Palazzo
Gerardo Palazzo
The functioning principles of electronic sensors based on organic semiconductor field-effect transistors (OFETs) are presented. The focus is on biological sensors but also chemical ones are reviewed to address general features. The field-induced electronic transport and the chemical and biological interactions for the sensing, each occurring at the relevant functional interface, are separately introduced. Once these key learning points have been acquired, the combined picture for the FET electronic sensing is proposed. The perspective use of such devices in point-of-care is introduced, after some basics on analytical biosensing systems are provided as well. This tutorial review includes also a necessary overview of the OFET sensing structures, but the focus will be on electronic rather than electrochemical detection. The differences among the structures are highlighted along with the implications on the performance level in terms of key analytical figures of merit such as: repeatability, sensitivity and selectivity.

5 June 2017 in Advanced Biosystems
Verified
Journal Article
Open access
PDF file
BHBrigitte Holzer
Brigitte Holzer
KMKyriaki Manoli
Kyriaki Manoli
NDNicoletta Ditaranto
Nicoletta Ditaranto
Eleonora MacchiaEleonora Macchia
Eleonora Macchia
ATAmber Tiwari
Amber Tiwari
Luisa TorsiLuisa Torsi
Luisa Torsi
Bioconjugated gold surfaces constitute interesting platforms for biosensing applications. The immobilization of antibodies such as anti‐immunoglobulin G and M (anti‐IgG and anti‐IgM) on gold electrodes via self‐assembled monolayers (SAMs) is here studied as a model system for further immunoassays development. The biolayer is characterized by means of X‐ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), a dedicated thin‐film transistor (TFT)‐based platform and electrochemical surface plasmon resonance (EC‐SPR). XPS analysis confirms the presence of all the chemical species involved in the fabrication process as well as the covalent attachment of the antibodies with high reproducibility. Visualization of the biolayer topography by AFM shows nanostructures with a thickness consistent with the actual size of the protein, which is also verified by SPR measurements. EC‐SPR allows taking advantage of complementary electrochemical and optical signals during the functionalization steps. Moreover, the functionalization of gold leads to a change in the work function, which is demonstrated in an electrolyte gated thin‐film transistor configuration. Such configuration enables also to evaluate the electrostatic changes occurring on the gate that are connected with the threshold voltage shifts. The data support that functional biomodified gold surfaces can be reproducibly prepared, which is a prerequisite for further biosensor development.

16 November 2015 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
MMM. Magliulo
M. Magliulo
MMMohammad Yusuf Shafi Mulla
Mohammad Yusuf Shafi Mulla
MSM. Singh
M. Singh
Eleonora MacchiaEleonora Macchia
Eleonora Macchia
ATA. Tiwari
A. Tiwari
KMKyriaki Manoli
Kyriaki Manoli
This review discusses the state-of-the-art strategies for realizing TFTs by printing compatible techniques, focusing the attention on label-free electronic biosensors.

11 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
KMKyriaki Manoli
Kyriaki Manoli
LDLiviu Mihai Dumitru
Liviu Mihai Dumitru
MMMohammad Yusuf Shafi Mulla
Mohammad Yusuf Shafi Mulla
MMMaria Magliulo
Maria Magliulo
CFCinzia Di Franco
Cinzia Di Franco
Luisa TorsiLuisa Torsi
Luisa Torsi
Bottom- and top-contact organic thin film transistors (OTFTs) were fabricated, using poly(3-hexylthiophene-2,5-diyl) (P3HT) and poly[2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene] (PBTTT-C16) as p-type channel semiconductors. Four different types of OTFTs were fabricated and investigated as gas sensors against three volatile organic compounds, with different associated dipole moments. The OTFT-based sensor responses were evaluated with static and transient current measurements. A comparison between the different architectures and the relative organic semiconductor was made.

30 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LSLucia Sarcina
Lucia Sarcina
Luisa TorsiLuisa Torsi
Luisa Torsi
Rosaria Anna PiccaRosaria Anna Picca
Rosaria Anna Picca
KMKyriaki Manoli
Kyriaki Manoli
Eleonora MacchiaEleonora Macchia
Eleonora Macchia
The continuous improvement of the technical potential of bioelectronic devices for biosensing applications will provide clinicians with a reliable tool for biomarker quantification down to the single molecule. Eventually, physicians will be able to identify the very moment at which the illness state begins, with a terrific impact on the quality of life along with a reduction of health care expenses. However, in clinical practice, to gather enough information to formulate a diagnosis, multiple biomarkers are normally quantified from the same biological sample simultaneously. Therefore, it is critically important to translate lab-based bioelectronic devices based on electrolyte gated thin-film transistor technology into a cost-effective portable multiplexing array prototype. In this perspective, the assessment of cost-effective manufacturability represents a crucial step, with specific regard to the optimization of the bio-functionalization protocol of the transistor gate module. Hence, we have assessed, using surface plasmon resonance technique, a sustainable and reliable cost-effective process to successfully bio-functionalize a gold surface, suitable as gate electrode for wide-field bioelectronic sensors. The bio-functionalization process herein investigated allows to reduce the biorecognition element concentration to one-tenth, drastically impacting the manufacturing costs while retaining high analytical performance.

1 January 2020
Verified
Book Chapter
Closed access
MMMohammad Y Mulla
Mohammad Y Mulla
LTLuisa Torsi
Luisa Torsi
KMKyriaki Manoli
Kyriaki Manoli