Yongsang Lee

Dr. Yongsang Lee

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
YLYongsang Lee
Yongsang Lee
SKSung Yong Kim
Sung Yong Kim
KOKyung Chul Oh
Kyung Chul Oh
Hong Seok MoonHong Seok Moon
Hong Seok Moon

1 January 2020 in The Journal of Korean Academy of Prosthodontics
Verified
Journal Article
Open access
PDF file
ICIn-Ho Choi
In-Ho Choi
SKSeong-A Kim
Seong-A Kim
NKNa-Hong Kim
Na-Hong Kim
YLYongsang Lee
Yongsang Lee
최인호, et al. J Korean Acad Prosthodont. 2020 Apr;58(2):145-152. https://doi.org/10.4047/jkap.2020.58.2.145

20 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KKKiWon Kim
KiWon Kim
SKSung Yong Kim
Sung Yong Kim
SKSeong-A Kim
Seong-A Kim
HJHeeWon Jang
HeeWon Jang
KLKeun-Woo Lee
Keun-Woo Lee
YLYongsang Lee
Yongsang Lee
In this study, we aimed to investigate the differences in tissue surface adaptation and the variations in distances between reference points on the polished surfaces of 3D-printed denture bases produced at different build angles. The build angles were 0°, 30°, 60°, and 90°, with 15 denture bases printed for each angle. Using the Geomagic Control® software, a 3D best-fit alignment was conducted between the denture base tissue surface and the reference shape of the edentulous maxilla model to calculate the root mean square error. The distances between reference points on the polished surface were measured using digital calipers. A one-way analysis of variance was conducted for statistical analysis. The adaptation, as measured by the root mean square error, varied significantly among denture bases with different build angles. The distances between the anterior and posterior reference points of the polished surface were also significantly different. However, within the limitations of this study, the variations in adaptations and dimensional accuracy across different build angles were within clinically acceptable ranges. In clinical practice, the print angle can be adjusted based on factors such as printing time, resin consumption, and the number of denture bases being printed simultaneously.

1 January 2024 in The Journal of Korean Academy of Prosthodontics
Verified
Journal Article
Open access
PDF file
MPMin-Jae Park
Min-Jae Park
JBJi-Won Bang
Ji-Won Bang
JBJoo-Hyuk Bang
Joo-Hyuk Bang
SLSeon-Young Lim
Seon-Young Lim
YLYongsang Lee
Yongsang Lee
SKSung Yong Kim
Sung Yong Kim
박민재, et al. J Korean Acad Prosthodont. 2024 Apr;62(2):104-112. https://doi.org/10.4047/jkap.2024.62.2.104

1 January 2019 in The Journal of Korean Academy of Prosthodontics
Verified
Journal Article
Open access
PDF file
BLBhumgey David Lee
Bhumgey David Lee
YLYongsang Lee
Yongsang Lee
Lee BD, et al. J Korean Acad Prosthodont. 2019 Jan;57(1):42-48. https://doi.org/10.4047/jkap.2019.57.1.42

1 January 2025 in The Journal of Korean Academy of Prosthodontics
Verified
Journal Article
Open access
PDF file
HLHyang Eun Lee
Hyang Eun Lee
SYSun-Young Yim
Sun-Young Yim
SKSung Yong Kim
Sung Yong Kim
HJHee-Won Jang
Hee-Won Jang
YLYongsang Lee
Yongsang Lee
JBJoo-Hyuk Bang
Joo-Hyuk Bang
이향은, et al. J Korean Acad Prosthodont. 2025 Apr;63(2):176-185. https://doi.org/10.4047/jkap.2025.63.2.176