Lorenza Petrini

Prof. Lorenza Petrini

Department of Civil and Environmental Engineering, Politecnico di Milano, Milan, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2002 in Journal of Biomechanics
Verified
Journal Article
Closed access
FMFrancesco Migliavacca
Francesco Migliavacca
Lorenza PetriniLorenza Petrini
Lorenza Petrini
MCMaurizio Colombo
Maurizio Colombo
FAFerdinando Auricchio
Ferdinando Auricchio
RPRiccardo Pietrabissa
Riccardo Pietrabissa

23 August 2004 in International Journal for Numerical Methods in Engineering
Verified
Journal Article
Closed access
PDF file
FAFerdinando Auricchio
Ferdinando Auricchio
Lorenza PetriniLorenza Petrini
Lorenza Petrini

5 November 2004 in Medical Engineering & Physics
Verified
Journal Article
Closed access
FMFrancesco Migliavacca
Francesco Migliavacca
Lorenza PetriniLorenza Petrini
Lorenza Petrini
VMValeria Montanari
Valeria Montanari
IQIsabella Quagliana
Isabella Quagliana
FAFerdinando Auricchio
Ferdinando Auricchio
GDGabriele Dubini
Gabriele Dubini
Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent expansion is an important factor to define the effectiveness of the surgical procedure: it depends on the stent geometry and includes large displacements and deformations, geometric and material non-linearity. Numerical analyses seem appropriate to study such a complex behaviour after a free stent expansion. In this study the finite element method (FEM) was applied to a new generation coronary stent. Results from computations were compared with those from a laboratory experiment in terms of radial expansion and elastic recoil. By means of a scanning electronic microscopy the area of plastic deformation were also detected and compared with those obtained in the numerical simulation. Matching between the different measurements was quite satisfactory even if some discrepancies were present due to the absence of the balloon in the numerical model.

1 April 2011 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DGDario Gastaldi
Dario Gastaldi
VSV. Sassi
V. Sassi
Lorenza PetriniLorenza Petrini
Lorenza Petrini
MVM. Vedani
M. Vedani
STStefano Trasatti
Stefano Trasatti
FMFrancesco Migliavacca
Francesco Migliavacca

1 January 2008 in Journal of Biomechanics
Verified
Journal Article
Closed access
FGFrancesca Gervaso
Francesca Gervaso
CCClaudio Capelli
Claudio Capelli
Lorenza PetriniLorenza Petrini
Lorenza Petrini
SLSimone Lattanzio
Simone Lattanzio
LVLuca Di Virgilio
Luca Di Virgilio
FMFrancesco Migliavacca
Francesco Migliavacca

5 September 2002 in International Journal for Numerical Methods in Engineering
Verified
Journal Article
Closed access
PDF file
FAFerdinando Auricchio
Ferdinando Auricchio
Lorenza PetriniLorenza Petrini
Lorenza Petrini