Francesco Migliavacca

Dr. Francesco Migliavacca

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2011 in Journal of Metallurgy
Verified
Journal Article
Open access
PDF file
LPLorenza Petrini
Lorenza Petrini
FMFrancesco Migliavacca
Francesco Migliavacca
Shape memory alloys, and in particular NiTi alloys, are characterized by two unique behaviors, thermally or mechanically activated: the shape memory effect and pseudo-elastic effect. These behaviors, due to the peculiar crystallographic structure of the alloys, assure the recovery of the original shape even after large deformations and the maintenance of a constant applied force in correspondence of significant displacements. These properties, joined with good corrosion and bending resistance, biological and magnetic resonance compatibility, explain the large diffusion, in the last 20 years, of SMA in the production of biomedical devices, in particular for mini-invasive techniques. In this paper a detailed review of the main applications of NiTi alloys in dental, orthopedics, vascular, neurological, and surgical fields is presented. In particular for each device the main characteristics and the advantages of using SMA are discussed. Moreover, the paper underlines the opportunities and the room for new ideas able to enlarge the range of SMA applications. However, it is fundamental to remember that the complexity of the material and application requires a strict collaboration between clinicians, engineers, physicists and chemists for defining accurately the problem, finding the best solution in terms of device design and accordingly optimizing the NiTi alloy properties.

30 September 2019 in European Heart Journal
Verified
Journal Article
Open access
FGFrank Gijsen
Frank Gijsen
YKYuki Katagiri
Yuki Katagiri
PBPeter Barlis
Peter Barlis
CBChristos Bourantas
Christos Bourantas
CCCarlos Collet
Carlos Collet
PSPatrick Serruys
Patrick Serruys

1 June 2002 in Journal of Biomechanics
Verified
Journal Article
Closed access
FMFrancesco Migliavacca
Francesco Migliavacca
Lorenza PetriniLorenza Petrini
Lorenza Petrini
MCMaurizio Colombo
Maurizio Colombo
FAFerdinando Auricchio
Ferdinando Auricchio
RPRiccardo Pietrabissa
Riccardo Pietrabissa

1 March 1996 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
MLM.R. de Leval
M.R. de Leval
GDG. Dubini
G. Dubini
FMFrancesco Migliavacca
Francesco Migliavacca
HJH. Jalali
H. Jalali
GAG. Camporini a
G. Camporini a
RPR. Pietrabissa
R. Pietrabissa

1 July 2007 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Closed access
SSSilvia Schievano
Silvia Schievano
LCLouise Coats
Louise Coats
FMFrancesco Migliavacca
Francesco Migliavacca
WNWendy Norman
Wendy Norman
AFAlessandra Frigiola
Alessandra Frigiola
ATAndrew M. Taylor
Andrew M. Taylor
Our aim was to identify sub-groups of right ventricular outflow tract morphology that would be suitable for percutaneous pulmonary valve implantation and to document their prevalence in our patient population. Eighty-three consecutive patients with right ventricular outflow tract dysfunction (5-41 years, 76% tetralogy of Fallot) referred to our center for cardiovascular magnetic resonance were studied. A morphological classification was created according to visual assessment of three-dimensional reconstructions and detailed measurement. Diagnosis, right ventricular outflow tract type, surgical history and treatment outcomes were documented. Right ventricular outflow tract morphology was heterogeneous; nevertheless, 5 patterns were visually identified. Type I, a pyramidal morphology, was most prevalent (49%) and related to the presence of a transannular patch. Other types (II-V) were seen more commonly in patients with conduits. Two patients had unclassifiable morphology. Ninety-five percent of patients were assigned to the correct morphological classification by visual assessment alone. Percutaneous pulmonary valve implantation was performed successfully in 10 patients with Type II-V morphology and in 1 patient with unclassifiable morphology. Percutaneous implantation was not performed in patients with Type I morphology. Only right ventricular outflow tract diameters < 22 mm in diameter were suitable for the current device. We have created a morphological classification of the RVOT in patients referred for assessment of RVOT dysfunction. Though only 13% of our patients underwent percutaneous implantation, > 50% of outflow tract morphologies may be suitable for this approach, in particular with the development of new devices appropriate for larger outflow.

1 February 2007 in Radiology
Verified
Journal Article
Closed access
SSSilvia Schievano
Silvia Schievano
FMFrancesco Migliavacca
Francesco Migliavacca
LCLouise Coats
Louise Coats
SKSachin Khambadkone
Sachin Khambadkone
MCMario Carminati
Mario Carminati
ATAndrew M. Taylor
Andrew M. Taylor
To determine if magnetic resonance (MR) imaging data can be used to create rigid models that are accurate representations of the right ventricular outflow tract (RVOT) and pulmonary trunk anatomy and if such models can be used to refine the selection of patients for percutaneous pulmonary valve implantation (PPVI). Institutional review board approval and informed patient consent were obtained. Twelve patients' MR data were analyzed and elaborated for input into a rapid prototyping (RP) system. RP models were successfully built and presented to two experienced cardiologists, who were retrospectively asked if they would have attempted PPVI. Their responses were compared with the documented decisions and outcomes of PPVI. For four subjects, both cardiologists correctly determined, on the basis of MR image or three-dimensional (3D) RP model findings, that PPVI should not have been attempted. Two patients in whom PPVI was attempted were considered to be unsuitable for the procedure after balloon sizing, and in another two patients, implantation was unsuccessful because of device instability. For the four patients in whom PPVI was suitable and the four in whom it was unsuitable, observers 1 and 2 correctly determined suitability for PPVI in four and two patients, respectively, by using the MR images alone. Both observers correctly determined the suitability of five patients by using the 3D models alone. Using 3D RP models resulted in more accurate selection of patients for PPVI than did using MR images.