Ashish Mathur

Dr. Ashish Mathur

University of Petroleum and Energy Studies, Dehra Dūn, India
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
Gourav BHATTACHARYAGourav BHATTACHARYA
Gourav BHATTACHARYA
SSShrawni Sas
Shrawni Sas
SWShikha Wadhwa
Shikha Wadhwa
Ashish MathurAshish Mathur
Ashish Mathur
JMJames McLaughlin
James McLaughlin
SRSusanta Sinha Roy
Susanta Sinha Roy
In the present work, the suitability of Aloe vera (AV) as a ‘green reducing agent’ has been investigated for the reduction of graphene oxide (GO). The extent of reduction was studied by varying the amount of AV. The physical and chemical properties of the GO and reduced graphene oxide (rGO) were investigated using UV-Vis spectrophotometry, FT-IR spectroscopy, High Resolution Transmission Electron Microscopy (HRTEM) and Selected Area Electron Diffraction (SAED). Partially reduced graphene oxide sheets obtained with 7.5 g of AV (rGO-7.5) demonstrated a maximum reduction efficiency of about 73% as evident from FT-IR data. Cyclic voltammetry and electrochemical impedance spectroscopy studies revealed a significant enhancement in current density and a decrease in charge transfer resistance for the rGO-7.5 sample. Moreover, the as prepared rGO-7.5 sample showed a remarkable dye removal ability with a maximum efficiency of ∼98%. The enhanced surface area, π–π interaction and strong electrostatic attraction were correlated with the dye removal capability. The adsorption kinetics were also studied and pseudo second order adsorption phenomena were confirmed. The recyclability of the rGO-7.5 sample was further investigated and an excellent desorption capability was established.

1 February 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JNJagriti Narang
Jagriti Narang
NMNitesh Malhotra
Nitesh Malhotra
CSChaitali Singhal
Chaitali Singhal
Ashish MathurAshish Mathur
Ashish Mathur
DCDhritiman Chakraborty
Dhritiman Chakraborty
CPChandra S. Pundir
Chandra S. Pundir

1 May 2020 in Bioresource Technology
Verified
Journal Article
Closed access
KBKannikka Behl
Kannikka Behl
PSPasupuleti SeshaCharan
Pasupuleti SeshaCharan
MJMonika Joshi
Monika Joshi
MSMahima Sharma
Mahima Sharma
Ashish MathurAshish Mathur
Ashish Mathur
SNSubhasha Nigam
Subhasha Nigam

1 November 2009 in Current Applied Physics
Verified
Journal Article
Closed access
Ashish MathurAshish Mathur
Ashish Mathur
SRSusanta Sinha Roy
Susanta Sinha Roy
MTM. Tweedie
M. Tweedie
SMS. Mukhopadhyay
S. Mukhopadhyay
SMSushanta Mitra
Sushanta Mitra
JIm Andrew MclaughlinJIm Andrew Mclaughlin
JIm Andrew Mclaughlin

27 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SNShalini Nagabooshanam
Shalini Nagabooshanam
SRSouradeep Roy
Souradeep Roy
Ashish MathurAshish Mathur
Ashish Mathur
IMIrani Mukherjee
Irani Mukherjee
SKSatheesh Krishnamurthy
Satheesh Krishnamurthy
LBLalit M. Bharadwaj
Lalit M. Bharadwaj
An Electrochemical micro Analytical Device (EµAD) was fabricated for sensitive detection of organophosphate pesticide chlorpyrifos in the food chain. Gold microelectrode (µE) modified with Zinc based Metal Organic Framework (MOF-Basolite Z1200) and Acetylcholinesterase (AChE) enzyme served as an excellent electro-analytical transducer for the detection of chlorpyrifos. Electrochemical techniques such as Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and Differential Pulse Voltammetry (DPV) were performed for electrochemical analysis of the developed EµAD. The sensor needs only 2 µL of the analyte and it was tested within the linear range of 10 to 100 ng/L. The developed EµAD’s limit of detection (LoD) and sensitivity is 6 ng/L and 0.598 µ A/ng L−1/mm2 respectively. The applicability of the device for the detection of chlorpyrifos from the real vegetable sample was also tested within the range specified. The fabricated sensor showed good stability with a shelf-life of 20 days. The EµAD’s response time is of 50 s, including an incubation time of 20 s. The developed EµAD was also integrated with commercially available low-cost, handheld potentiostat (k-Stat) using Bluetooth and the results were comparable with a standard electrochemical workstation.

1 November 2018 in Process Biochemistry
Verified
Journal Article
Closed access
CSChaitali Singhal
Chaitali Singhal
ADAmidha Dubey
Amidha Dubey
Ashish MathurAshish Mathur
Ashish Mathur
CPC.S. Pundir
C.S. Pundir
JNJagriti Narang
Jagriti Narang