To understand influenza vaccination and its correlates among health-careworkers (HCWs) during the 2019/2020 season in China, we used a self-administeredelectronic questionnaire to collect information on demographics, occupational characteristics, influenza vaccination status and access to free vaccination on the “Breath Circles”, a Chinese media platform for respiratory medical professionals. The reported influenza vaccine coverage among HCWs during this season was 67%, with more HCWs in a workplace with free vaccination than those with no free vaccination (79% vs.34%,p < .001). The influenza vaccine coverage among HCWs who were required or encouraged to get vaccinated by the workplace was significantly higher than that without any intervention measures (80% & 70 vs.39%,p < .001). The vaccine coverage in the workplaces with free and required vaccination simultaneously was highest compared to that with neither free vaccination nor any intervention measures (OR = 14.86, 95% CI: 10.93–20.20). The influenza vaccination coverage of HCWs in high-riskdepartments was significantly higher than that of other departments (70% vs.58%,p =.023). HCWs’ vaccine coverage was related to personal opinions and attitudes toward influenza or influenza vaccines, as well as other constraints such as availability of influenza vaccines, workplace regulations, and access to free vaccines.
Magnetic particle imaging (MPI) is a radiation-free vessel- and target-imaging modality that can sensitively detect nanoparticles. A static magnetic gradient field, referred to as a selection field, is required in MPI to provide a field-free region (FFR) for spatial encoding. The image resolution of MPI is closely related to the size of the FFR, which is determined by the selection field gradient amplitude. Because of the limitations of existing gradient coil hardware, the image resolution of MPI cannot satisfy the clinical requirements of human in vivo imaging. Pulsed excitation has been confirmed to improve the image resolution of MPI by breaking down the ’relaxation wall.’ This work proposes the use of a pulsed waveform magnetic gradient from magnetic resonance imaging to further improve the image resolution of MPI. Through alignment of the gradient direction along the field-free line (FFL), each location on the FFL is able to have a unique excitation field strength that generates a specific relaxation-induced decay signal. Through excitation of nanoparticles on the FFL with many gradient profiles, a high-resolution, one-dimensional (1D) image can be reconstructed on the FFL. For larger magnetic nanoparticles, simulation results revealed that a pulsed excitation field with a greater flat portion generates a 1D bar pattern phantom image with a higher correlation and spatial resolution. With parallel FFL and gradient coil movements, high-resolution, two-dimensional (2D) Shepp–Logan phantom and brain vessel maps were reconstructed through repetition of the spatially resolved measurement of magnetic nanoparticles on the FFL.
Background: To evaluate the immunogenicity, antibody persistence, and safety of the 60 µg hepatitis B vaccine in hemodialysis patients in China. Methods: We conducted a multicenter, randomized, double-blind, parallel-controlled trial including 352 hemodialysis patients who were centrally randomized in a ratio of 1:1 to receive a 20 µg (IM20 group) or 60 µg (IM60 group) recombinant hepatitis B vaccine at months 0, 1, and 6. Results: The vaccine-elicited antibody responses peaked at month 7, and declined at month 12. At month 7, the IM60 group had stronger GMC of anti-HBs, and a higher proportion of seroconversion and high-level response than the IM20 group did (P < 0.05). Better immune responses were observed in the IM60 group, especially for those aged or in the high-frequency hemodialysis population. Conclusion: The high dose 60 µg recombinant hepatitis B vaccines elicited stronger immune responses than the 20 µg hepatitis B vaccine did among hemodialysis patients. Clinical trial registration: ClinicalTrials.gov, number NCT02963714.