Due to overlapping tremor features, the medical diagnosis of Parkinson’s disease (PD) and essential tremor (ET) mainly relies on the clinical experience of doctors, which often leads to misdiagnosis. Seven predictive models using machine learning algorithms including random forest (RF), eXtreme Gradient Boosting (XGBoost), support vector machine (SVM), logistic regression (LR), ridge classification (Ridge), backpropagation neural network (BP), and convolutional neural network (CNN) were evaluated and compared aiming to better differentiate between PD and ET by using accessible demographics and tremor information of the upper limbs. The tremor information including tremor acceleration and surface electromyogram (sEMG) signals were collected from 398 patients (PD = 257, ET = 141) and then were used to train the established models to separate PD and ET. The performance of the models was evaluated by indices of accuracy and area under the curve (AUC), which indicated the ensemble learning models including RF and XGBoost showed the best overall predictive ability with accuracy above 0.84 and AUC above 0.90. Furthermore, the relative importance of sex, age, four postures, and five tremor features was analyzed and ranked showing that the dominant frequency of sEMG of flexors, the average amplitude of sEMG of flexors, resting posture, and winging posture had a greater impact on the diagnosis of PD, whereas sex and age were less important. These results provide a reference for the intelligent diagnosis of PD and show promise for use in wearable tremor suppression devices.
Parkinsonian tremor (PT) and Essential tremor (ET) exist as upper limb tremors in clinical practice. Notably, their types of trembling share similar presentations and overlapping frequencies. To enhance objectivity and efficiency in the diagnosis of these two diseases, there is a pressing need for more objective tremor classification procedures. This study proposes a novel multimodal fusion network based on a cross-attention mechanism (MFCA-Net) to automate the classification of upper limb tremors between PTs and ETs. To this end, 140 patients with PTs and ETs were recruited, and acceleration and surface electromyography (sEMG) signals were collected from the forearm during tremor episodes. To comprehensively capture the global and local features of input signals, a multiscale convolution in MFCA-Net was designed. Furthermore, the cross-attention mechanism was applied to fuse the features of the two input signals. The results demonstrate that the final classification accuracy exceeded 97.18% when MFCA-Net was used. Compared with the single acceleration signal and single sEMG signal inputs, the recognition accuracies increased by 18.91% and 10.04%, respectively. Therefore, the proposed MFCA-Net in this study serves as an objective and potential tool for assisting clinicians in the diagnosis of PT and ET patients.
Purpose: A control algorithm for radio-frequency-induced intestinal tissue fusion was developed to explore the effects of different control parameters on intestinal tissue fusion. Materials and methods: Radio-frequency-induced fusion was performed on ex vivo small intestine tissue. The effect on the fusion was observed by changing the control parameters (power, interval time, and terminal impedance) in the algorithm. The quality of fusion was evaluated using the burst pressure and thermal damage measurement. Histological evaluation was used to assess the fusion quality indirectly. Results: A maximum burst pressure of 8.460 ± 0.2674 KPa was acquired when the power was set to 100 W, the interval time was set to 2000 ms, and the terminal impedance was set to 50 Ω. Moreover, the thermal damage range increased with an increase in power but decreased with an increase in the interval time and terminal impedance. Furthermore, the thermal damage range and temperature were presumably related. Conclusions: For an ex vivo small intestine tissue, the appropriate control parameters could be set when the power was approximately 100 W, the interval time was approximately 2000 ms, and the terminal impedance was approximately 50 Ω. This study could provide a basis for the selection of control parameters for intestinal tissue fusion.