We present an easily accessible model for dispatch and expansion planning of the German multi-modal energy system from today until 2050. The model can be used with low efforts while comparing favorably with historic data and other studies of future developments. More specifically, the model is based on a linear programming partial equilibrium framework and uses a compact set of technologies to ease the comprehension for new modelers. It contains all equations and parameters needed, with the data sources and model assumptions documented in detail. All code and data are openly accessible and usable. The model can reproduce today’s energy mix and its CO2 emissions with deviations below 10%. The generated energy transition path, for an 80% CO2 reduction scenario until 2050, is consistent with leading studies on this topic. Our work thus summarizes the key insights of previous works and can serve as a validated and ready-to-use platform for other modelers to examine additional hypotheses.
CO$_2$ emission reduction and increasing volatile renewable energy generation mandate stronger energy sector coupling and the use of energy storage. In such multi-modal energy systems, it is challenging to determine the effect of an individual player's consumption pattern onto overall CO$_2$ emissions. This, however, is often important to evaluate the suitability of local CO$_2$ reduction measures. Due to renewables' volatility, the traditional approach of using annual average CO$_2$ intensities per energy form is no longer accurate, but the time of consumption should be considered. Moreover, CO$_2$ intensities are highly coupled over time and different energy forms due to sector coupling and energy storage. We introduce and compare two novel methods for computing time-dependent CO$_2$ intensities, that address different objectives: the first method determines CO$_2$ intensities of the energy system as is. The second method analyzes how overall CO$_2$ emissions would change in response to infinitesimal demand changes. Given a digital twin of the energy system in form of a linear program, we show how to compute these sensitivities very efficiently. We present the results of both methods for two simulated test energy systems and discuss their different implications.
We examine the carbon mitigation potential of operational adjustments for a German university campus. To this end, we compare the modeled cost-optimal operation with CO 2 -minimizing dispatch plans where different limits for the additional, specific CO 2 mitigation costs are set. At first, the operational mitigation potential of today's combined heat and power (CHP) driven energy system is analyzed. Then we examine the possible effects of increased flexibility of this multi-energy system by adding heat pumps and heat storage. We include a detailed account of today's operational cost structure including taxes and subsidies. To correctly represent the CO 2 footprint of consumed electricity from the grid, we consider the CO 2 intensity of Germany's electricity mix as time-dependent. This is important to correctly honor the impact of the multi-energy system's flexibility. We find that given the current regulatory environment, without considering investment costs, large CO 2 reductions compared to the modeled cost-optimal operation can only be achieved for specific CO 2 mitigation costs above 150€/t. Small reductions can be obtained at much lower cost when a heat pump operates in parallel with the CHP. However, for all scenarios the CO 2 reductions can only be realized by exploiting periods with low CO 2 intensity of the grid's electricity.