Introduction: Visualization of B-lines via lung ultrasound provides a non-invasive estimation of pulmonary hydration. Extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) assessed by transpulmonary thermodilution (TPTD) represent the most validated parameters of lung water and alveolocapillary permeability, but measurement is invasive and expensive. This study aimed to compare the correlations of B-lines scores from extensive 28-sector and simplified 4-sector chest scan with EVLWI and PVPI derived from TPTD in the setting of intensive care unit (primary endpoint). Methods: We performed scoring of 28-sector and 4-sector B-Lines in 50 critically ill patients. TPTD was carried out with the PiCCO-2-device (Pulsion Medical Systems SE, Maquet Getinge Group). Median time exposure for ultrasound procedure was 12 minutes for 28-sector and 4 minutes for 4-sector scan. Results: Primarily, we found close correlations of 28-sector as well as 4-sector B-Lines scores with EVLWI (R2 = 0.895 vs. R2 = 0.880) and PVPI (R2 = 0.760 vs. R2 = 0.742). Both B-lines scores showed high accuracy to identify patients with specific levels of EVLWI and PVPI. The extensive 28-sector B-lines score revealed a moderate advantage compared to simplified 4-sector scan in detecting a normal EVLWI ≤ 7 (28-sector scan: sensitivity = 81.8%, specificity = 94.9%, AUC = 0.939 versus 4-sector scan: sensitivity = 81.8%, specificity = 82.1%, AUC = 0.902). Both protocols were approximately equivalent in prediction of lung edema with EVLWI ≥ 10 (28-sector scan: sensitivity = 88.9%, specificity = 95.7%, AUC = 0.977 versus 4-sector scan: sensitivity = 81.5%, specificity = 91.3%, AUC = 0.958) or severe pulmonary edema with EVLWI ≥ 15 (28-sector scan: sensitivity = 91.7%, specificity = 97.4%, AUC = 0.995 versus 4-sector scan: sensitivity = 91.7%, specificity = 92.1%, AUC = 0.978). As secondary endpoints, our evaluations resulted in significant associations of 28-sector as well as simplified 4-sector B-Lines score with parameters of respiratory function. Conclusion: Both B-line protocols provide accurate non-invasive evaluation of lung water in critically ill patients. The 28-sector scan offers a marginal advantage in prediction of pulmonary edema, but needs substantially more time than 4-sector scan.
Acute-on-chronic liver failure (ACLF) is associated with high mortality. Objective prognostic scores are important for treatment decisions. EASIX (Endothelial Activation and Stress Index) is a simple biomarker consisting of LDH, platelets, and creatinine, reflecting endothelial dysfunction after allogeneic stem cell transplantation. Considering endothelial dysfunction in the pathogenesis of ACLF, this study aimed to test the discriminative ability of EASIX in advanced liver disease. We retrospectively analysed the prognostic potential of EASIX to predict 28-day and 3-month mortality in a total of 188 liver cirrhotic patients requiring treatment at the intensive care unit. We evaluated the ability of EASIX to rule out early infections and predict the need for hemodialysis. EASIX performed moderately better than established scores in predicting 28-day mortality (AUC = 0.771) and was nearly equivalent (AUC = 0.791) to SOFA and APACHE-II in the prediction of 3-month mortality. Importantly, EASIX showed better diagnostic potential in ruling out clinically apparent infections than common proinflammatory markers (AUC = 0.861, p < 0.001) and showed suitable accuracy in predicting the need for hemodialysis (AUC = 0.833). EASIX is an accurate, objective and easily assessable biomarker for predicting mortality and complications in patients with advanced liver disease.
Malnutrition in critically ill patients with cirrhosis is a frequent but often overlooked complication with high prognostic relevance. The Nutrition Risk in Critically ill (NUTRIC) score and its modified variant (mNUTRIC) were established to assess the nutrition risk of intensive care unit patients. Considering the high mortality of cirrhosis in critically ill patients, this study aims to evaluate the discriminative ability of NUTRIC and mNUTRIC to predict outcome. We performed a retro-prospective evaluation in 150 Caucasian cirrhotic patients admitted to our ICU. Comparative prognostic analyses between NUTRIC and mNUTRIC were assessed in 114 patients. On ICU admission, a large proportion of 65% were classified as high NUTRIC (6–10) and 75% were categorized as high mNUTRIC (5–9). High nutritional risk was linked to disease severity and poor outcome. NUTRIC was moderately superior to mNUTRIC in prediction of 28-day mortality (area under curve 0.806 vs. 0.788) as well as 3-month mortality (area under curve 0.839 vs. 0.819). We found a significant association of NUTRIC and mNUTRIC with MELD, CHILD, renal function, interleukin 6 and albumin, but not with body mass index. NUTRIC and mNUTRIC are characterized by high prognostic accuracy in critically ill patients with cirrhosis. NUTRIC revealed a moderate advantage in prognostic ability compared to mNUTRIC.
Background Early identification of patients with acute severe pancreatitis is important for prompt and adequate treatment. Existing scores for pancreatitis are often laborious or require serial patient evaluation, whereas the qSOFA score, that was established to predict outcome in patients with suspected infection, is simple to perform. Aims and Methods In this cohort study, we analyse the potential of the qSOFA score to predict outcome of patients with acute pancreatitis and refine the qSOFA score by rapid available laboratory parameters to the emergency room assessment of acute pancreatitis (ERAP) score. Validation was performed in a separate patient cohort. Results In total 203 patients with acute pancreatitis were recruited. The qSOFA score has the potential to predict ICU admission (AUC = 0.730, p = 0.002) and organ failure (AUC = 0.799, p = 0.013) in acute pancreatitis. Respiratory rate, mental status, blood urea nitrogen and C-reactive protein are the rapid available parameters with the highest individual impact in binary logistic regression analyses. Their combination to the ERAP score can predict severity of acute pancreatitis according to the revised Atlanta classification (AUC = 0.689 ± 0.041, p < 0.001), ICU admission (AUC = 0.789 ± 0.067, p < 0.001), multi-organ dysfunction syndrome (AUC = 0.963 ± 0.024, p < 0.001) and mortality (AUC = 0.952 ± 0.028, p = 0.001). The performance and prognostic validity for organ failure and mortality were validated in an independent patient cohort. Conclusion The qSOFA is a rapidly available prognostic score in acute pancreatitis with limited prognostic validity. A combination with the laboratory parameters BUN and CRP results in the new ERAP score with outstanding prognostic validity for multi-organ dysfunction syndrome and mortality.
Ascites is a major and common complication of liver cirrhosis. Large or refractory ascites frequently necessitates paracentesis. The aim of our study was to investigate the effects of paracentesis on hemodynamic and respiratory parameters in critically ill patients.
Ascites is a major complication of decompensated liver cirrhosis. Intraabdominal hypertension and structural alterations of parenchyma involve decisive changes in hepatosplanchnic blood flow. Clearance of indo-cyanine green (ICG) is mainly dependent on hepatic perfusion and hepatocellular function. As a consequence, plasma disappearance rate of ICG (ICG-PDR) is rated as a useful dynamic parameter of liver function. This study primarily evaluates the impact of large-volume paracentesis (LVP) on ICG-PDR in critically ill patients with decompensated cirrhosis. Additionally, it describes influences on intraabdominal pressure (IAP), abdominal perfusion pressure (APP), hepatic blood flow, hemodynamic and respiratory function. We analyzed LVP in 22 patients with decompensated liver cirrhosis. ICG-PDR was assessed by using noninvasive LiMON technology (Pulsion® Medical Systems; Maquet Getinge Group), and hepatic blood flow was analyzed by color-coded duplex sonography. Paracentesis of a median volume of 3450 mL ascites evoked significant increases of ICG-PDR from 3.6 (2.8–4.6) to 5.1 (3.9–6.2)%/min (p < 0.001). Concomitantly, we observed a raise in “ICG-Clearance” from 99 (73.5–124.5) to 104 (91–143.5) mL/min/m2 (p = 0.005), while circulating blood volume index was unchanged [2412 (1983–3025) before paracentesis vs. 2409 (1997–2805) mL/m2, p = 0.734]. Sonography revealed a significant impact of paracentesis on hepatic blood flow: Hepatic artery resistance index dropped from 0.74 (0.68–0.75) to 0.68 (0.65–0.71) (p < 0.001) and maximum flow velocity in hepatic vein increased from 24 (17–30) to 30 (22–36) cm/s (p < 0.001). Consistent with previous studies, paracentesis caused significant decreases in IAP from 19.0 (15.0–20.3) to 11.0 (8.8–12.3) mmHg (p < 0.001) and central venous pressure from 22.5 (17.8–29.0) to 17.5 (12.8–24.0) mmHg (p < 0.001) with inverse increases in APP from 63.0 (56.8–69.5) to 71.0 (65.5–78.5) mmHg (p < 0.001). Changes in ICG-PDR were concomitant with changes in IAP (r = − 0.602) and APP (r = 0.576). Moreover, we found a substantial improvement in respiratory function. By contrast, hemodynamic parameters assessed by transpulmonary thermodilution, serum bilirubin and international normalized ratio did not change after paracentesis. Critically ill patients with decompensated cirrhosis and elevated IAP showed dramatically impaired ICG-PDR. Paracentesis evoked an improvement in ICG-PDR in parallel with a decreased IAP and an increased APP, while conventional parameters of liver function did not change. This effect on ICG-PDR is mainly referable to a relief of intraabdominal hypertension and changes in hepatosplanchnic blood flow.