Accurate temperature and thermal dose prediction are crucial to high-intensity focused ultrasound (HIFU) hyperthermia, which has been used successfully for the non-invasive treatment of solid tumors. For the conventional method of prediction, the tissue properties are usually set as constants. However, the temperature rise induced by HIFU irradiation in tissues will cause changes in the tissue properties that in turn affect the acoustic and temperature field. Herein, an acoustic–thermal coupling model is presented to predict the temperature and thermal damage zone in tissue in terms of the Westervelt equation and Pennes bioheat transfer equation, and the individual influence of each dynamic tissue property and the joint effect of all of the dynamic tissue properties are studied. The simulation results show that the dynamic acoustic absorption coefficient has the greatest influence on the temperature and thermal damage zone among all of the individual dynamic tissue properties. In addition, compared with the conventional method, the dynamic acoustic absorption coefficient leads to a higher focal temperature and a larger thermal damage zone; on the contrary, the dynamic blood perfusion leads to a lower focal temperature and a smaller thermal damage zone. Moreover, the conventional method underestimates the focal temperature and the thermal damage zone, compared with the simulation that was performed using all of the dynamic tissue properties. The results of this study will be helpful to guide the doctors to develop more accurate clinical protocols for HIFU treatment planning.
In this work, a high-sensitivity terahertz (THz) biosensor is achieved by using a graphene/Bragg reflector hybrid structure. This high-sensitivity THz biosensor is developed from the sharp Fano resonance transmission peak created by coupling the graphene Tamm plasmons (GTPs) mode to a defect mode. It is found that the proposed THz biosensor is highly sensitive to the Fermi energy of graphene, as well as the thickness and refractive index of the sensing medium. Through specific parameter settings, the composite structure can achieve both a liquid biosensor and a gas biosensor. For the liquid biosensor, the maximum sensitivity of is obtained by selecting appropriate parameters. We believe the proposed layered hybrid structure has the potential to fabricate graphene-based high-sensitivity biosensors.
6 September 2018 in Advances in Condensed Matter Physics
The coupled effects of blood vessels and thermal relaxation time on temperature and thermal lesion region in biological tissue during high-intensity focused ultrasound (HIFU) hyperthermia are numerically investigated. Considering the non-Fourier behavior of heat conduction in biological tissue, the traditional Pennes bioheat equation was modified to thermal wave model of bioheat transfer (TWMBT). Consequently, a joint physical model, which combines TWMBT for tissue and energy transport equation for blood vessel, is presented to predict the evolution of temperature and the thermal lesion region. In this study, pulsatile blood flow is first introduced into numerical study of HIFU hyperthermia, and thermal relaxation time, ultrasonic focus location, blood vessel radius, and blood flow velocity are all taken into account. The results show that the thermal relaxation time plays a key role in the temperature and the thermal lesion region. Larger thermal relaxation time results in lower temperature and smaller thermal lesion region, which indicates that TWMBT leads to lower temperature and smaller thermal lesion region compared to Pennes bioheat transfer model. In addition, we found that the ultrasonic focus location and blood vessel radius significantly affected the temperature and thermal lesion region, while the heartbeat frequency and amplitude factor of pulsating blood flow as well as the average velocity of blood flow had only a slight effect.
PurposeSegmentation of ultrasound images for medical diagnosis, monitoring, and research is crucial, and although existing methods perform well, they are limited by specific organs, tumors, and image devices. Applications of the Segment Anything Model (SAM), such as SAM-med2d, use a large number of medical datasets that contain only a small fraction of the ultrasound medical images.ApproachIn this work, we proposed a SAM-MedUS model for generic ultrasound image segmentation that utilizes the latest publicly available ultrasound image dataset to create a diverse dataset containing eight site categories for training and testing. We integrated ConvNext V2 and CM blocks in the encoder for better global context extraction. In addition, a boundary loss function is used to improve the segmentation of fuzzy boundaries and low-contrast ultrasound images.ResultsExperimental results show that SAM-MedUS outperforms recent methods on multiple ultrasound datasets. For the more easily datasets such as the adult kidney, it achieves 87.93% IoU and 93.58% dice, whereas for more complex ones such as the infant vein, IoU and dice reach 62.31% and 78.93%, respectively.ConclusionsWe collected and collated an ultrasound dataset of multiple different site types to achieve uniform segmentation of ultrasound images. In addition, the use of additional auxiliary branches ConvNext V2 and CM block enhances the ability of the model to extract global information and the use of boundary loss allows the model to exhibit robust performance and excellent generalization ability.
Experimental studies have shown that ultrasonic cavitation can reversibly open the blood-brain barrier (BBB) to assist drug delivery. Nevertheless, the majority of the present study focused on experimental aspects of BBB opening. In this study, we developed a three-bubble-liquid-solid model to investigate the dynamic behavior of multiple bubbles within the blood vessels, and elucidate the physical mechanism of drug molecules through endothelial cells under ultrasonic cavitation excitation. The results showed that the large bubbles have a significant inhibitory effect on the movement of small bubbles, and the vibration morphology of intravascular microbubbles was affected by the acoustic parameters, microbubble size, and the distance between the microbubbles. The ultrasonic cavitation can significantly enhance the unidirectional flux of drug molecules, and the unidirectional flux growth rate of the wall can reach more than 5 %. Microjets and shock waves emitted from microbubbles generate different stress distribution patterns on the vascular wall, which in turn affects the pore size of the vessel wall and the permeability of drug molecules. The vibration morphology of microbubbles is related to the concentration, arrangement and scale of microbubbles, and the drug permeation impact can be enhanced by optimizing bubble size and acoustic parameters. The results offer an extensive depiction of the factors influencing the blood-brain barrier opening through ultrasonic cavitation, and the model may provide a potential technique to actively regulate the penetration capacity of drugs through endothelial layer of the neurovascular system by regulating BBB opening.
Through the introduction of multifrequency ultrasound technology, remarkable results have been achieved in tissue ablation and other aspects. By using the nonlinear dynamic equation of spherical bubble, the effects of the combination mode of multifrequency ultrasound, the peak negative pressure and its duration, the phase angle difference, and the polytropic index on the transient cavitation threshold in four different media of water, blood, brain, and liver are simulated and analyzed. The simulation results show that under the same frequency difference and initial bubble radius, the transient cavitation threshold of the high-frequency, triple-frequency combination is higher than that of the low-frequency, triple-frequency combination. When the lowest frequency of triple frequencies is the same, the larger the frequency difference, the higher the transient cavitation threshold. When the initial bubble radius is small, the frequency difference has little effect on the transient cavitation threshold of the triple-frequency combination. With the increase of initial bubble radius, the influence of frequency difference on the transient cavitation threshold of the higher frequency combination of triple frequency is more obvious than that of the lower frequency combination of triple frequency. When the duration of peak negative pressure or peak negative pressure of the multifrequency combined ultrasound is longer than that of the single-frequency ultrasound, the transient cavitation threshold of the multifrequency combined ultrasound is lower than that of the single-frequency ultrasound; on the contrary, the transient cavitation threshold of the multifrequency combined ultrasound is higher than that of the single-frequency ultrasound. When the phase angle difference of multifrequency excitation is zero, the corresponding transient cavitation threshold is the lowest, while the change of the polytropic index has almost no effect on the transient cavitation threshold for the multifrequency combination. The research results can provide a reference for multifrequency ultrasound to reduce the transient cavitation threshold, which is of great significance for the practical application of cavitation.