David Infield

Prof. David Infield


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
CMConor McKinnon
Conor McKinnon
JCJames Carroll
James Carroll
AMAlasdair McDonald
Alasdair McDonald
SKSofia Kokoura
Sofia Kokoura
DIDavid Infield
David Infield
CSConaill Soraghan
Conaill Soraghan
Anomaly detection for wind turbine condition monitoring is an active area of research within the wind energy operations and maintenance (O & M) community. In this paper three models were compared for multi-megawatt operational wind turbine SCADA data. The models used for comparison were One-Class Support Vector Machine (OCSVM), Isolation Forest (IF), and Elliptical Envelope (EE). Each of these were compared for the same fault, and tested under various different data configurations. IF and EE have not previously been used for fault detection for wind turbines, and OCSVM has not been used for SCADA data. This paper presents a novel method of condition monitoring that only requires two months of data per turbine. These months were separated by a year, the first being healthy and the second unhealthy. The number of anomalies is compared, with a greater number in the unhealthy month being considered correct. It was found that for accuracy IF and OCSVM had similar performances in both training regimes presented. OCSVM performed better for generic training, and IF performed better for specific training. Overall, IF and OCSVM had an average accuracy of 82% for all configurations considered, compared to 77% for EE.

1 July 2013 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
YWYue Wang
Yue Wang
DIDavid Infield
David Infield
Offshore wind energy is catching increasing worldwide interest. However, access and maintenance offshore can be difficult and will be more costly than onshore, and hence, availability is correspondingly lower. As a result, there is a growing interest in wind turbine condition monitoring with condition‐based rather than responsive and scheduled maintenance. A non‐linear state estimation technique (NSET) model is presented here to model a healthy wind turbine gearbox using stored historical data. These data capture the inter‐relationship between the model input and output parameters. The state vectors comprising the data should cover as much as turbine operational range, including the extreme conditions in order to obtain an accurate model performance. A model so constructed can be applied to assess the operational data. Welch's t ‐test is employed in the fault detection algorithm, together with suitable time series filtering, to identify incipient anomalies in the turbine gearbox before they develop into catastrophic faults. Two case studies based on 10‐minute supervisory control and data acquisition data from a commercial wind farm are presented to demonstrate the model's effectiveness. Comparison is made with neural network modelling, and the NSET approach is demonstrated to be superior.

16 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Ravi PanditRavi Pandit
Ravi Pandit
DIDavid Infield
David Infield
TDTim Dodwell
Tim Dodwell
Offshore wind turbines are complex pieces of engineering and are, generally, exposed to harsh environmental conditions that are making them to susceptible unexpected and potentially catastrophic damage. This results in significant downtime and high maintenance costs. Therefore, early detection of major failures is important to improve availability, boost power production, and reduce maintenance costs. This article proposes a supervisory control and data acquisition (SCADA) data-based Gaussian process (GP) (a data-driven, machine learning approach) fault detection algorithm where additional model inputs called operational variables (pitch angle and rotor speed) are used. First, comparative studies of these operational variables are carried out to establish whether the parameter leads to improved early fault detection capability; it is then used to construct an improved GP fault detection algorithm. The developed model is then validated against existing methods in terms of capability to detect in advance (and by how much) signs of failure with a low false positive rate. Failure due to yaw misalignment results in significant downtime and a reduction in power production was found to be a useful case study to demonstrate the effectiveness of the proposed algorithms. Historical SCADA 10-min data obtained from pitch-regulated turbines were used for models training and validation purposes. Results show that: 1) additional model inputs were able to improve the accuracy of GP power curve models with rotor speed responsible for a significant improvement in performance and 2) inclusion of rotor speed enhanced early failure detection without any false positives, in contrast to the other methods investigated.

5 September 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Open access
Ravi PanditRavi Pandit
Ravi Pandit
DIDavid Infield
David Infield
Matilde SantosMatilde Santos
Matilde Santos
Continuous assessment of wind turbine performance is a key to maximising power generation at a very low cost. A wind turbine power curve is a non-linear function between power output and wind speed and is widely used to approach numerous problems linked to turbine operation. According to the current IEC standard, power curves are determined by a data reduction method, called binning, where hub height, wind speed and air density are considered as appropriate input parameters. However, as turbine rotors have grown in size over recent years, the impact of variations in wind speed, and thus of power output, can no longer be overlooked. Two environmental variables, namely wind shear and turbulence intensity, have the greatest impact on power output. Therefore, taking account of these factors may improve the accuracy as well as reduce the uncertainty of data-driven power curve models, which could be helpful in performance monitoring applications. This paper aims to quantify and analyse the impact of these two environmental factors on wind turbine power curves. Gaussian process (GP) is a data-driven, nonparametric based approach to power curve modelling that can incorporate these two additional environmental factors. The proposed technique's effectiveness is trained and validated using historical 10-minute average supervisory control and data acquisition (SCADA) datasets from variable speed, pitch control, and wind turbines rated at 2.5 MW. The results suggest that (i) the inclusion of the additional environmental parameters increases GP model accuracy and reduces uncertainty in estimating the power curve; (ii) a comparative study reveals that turbulence intensity has a relatively greater impact on GP model accuracy, together with uncertainty as compared to blade pitch angle. These conclusions are confirmed using performance error metrics and uncertainty calculations. The results have practical beneficial consequences for O&M related activities such as early failure detection.

12 October 2018 in International Journal of Energy and Environmental Engineering
Verified
Journal Article
Open access
PDF file
Ravi PanditRavi Pandit
Ravi Pandit
DIDavid Infield
David Infield
The unexpected failure of wind turbine components leads to significant downtime and loss of revenue. To prevent this, supervisory control and data acquisition (SCADA) based condition monitoring is considered as a cost-effective approach. In several studies, the wind turbine power curve has been used as a critical indicator for power performance assessment. In contrast, the application of the blade pitch angle curve has hardly been explored for wind turbine condition monitoring purposes. The blade pitch angle curve describes the nonlinear relationship between pitch angle and hub height wind speed and can be used for the detection of faults. A support vector machine (SVM) is an improved version of an artificial neural networks (ANN) and is widely used for classification- and regression-related problems. Support vector regression is a data-driven approach based on statistical learning theory and a structural risk minimization principle which provides useful nonlinear system modeling. In this paper, a support vector regression (a nonparametric machine learning approach)-based pitch curve is presented and its application to anomaly detection explored for wind turbine condition monitoring. A radial basis function (RBF) was used as the kernel function for effective SVR blade pitch curve modeling. This approach is then compared with a binned pitch curve in the identification of operational anomalies. The paper will outline the advantages and limitations of these techniques.

14 December 2012 in Energies
Verified
Journal Article
Open access
PDF file
PGPeng Guo
Peng Guo
DIDavid Infield
David Infield
With appropriate vibration modeling and analysis the incipient failure of key components such as the tower, drive train and rotor of a large wind turbine can be detected. In this paper, the Nonlinear State Estimation Technique (NSET) has been applied to model turbine tower vibration to good effect, providing an understanding of the tower vibration dynamic characteristics and the main factors influencing these. The developed tower vibration model comprises two different parts: a sub-model used for below rated wind speed; and another for above rated wind speed. Supervisory control and data acquisition system (SCADA) data from a single wind turbine collected from March to April 2006 is used in the modeling. Model validation has been subsequently undertaken and is presented. This research has demonstrated the effectiveness of the NSET approach to tower vibration; in particular its conceptual simplicity, clear physical interpretation and high accuracy. The developed and validated tower vibration model was then used to successfully detect blade angle asymmetry that is a common fault that should be remedied promptly to improve turbine performance and limit fatigue damage. The work also shows that condition monitoring is improved significantly if the information from the vibration signals is complemented by analysis of other relevant SCADA data such as power performance, wind speed, and rotor loads.