In closed hazardous waste (i.e. industrial) landfills, impermeable covers are used to seal in the waste so as to minimise water infiltration and the accumulation of leachate inside the waste. In this paper, we present a geophysical study performed on a French landfill where the cover was designed using impermeable (clay) and drainage (sand) layers along with a Geosynthetic Clay Liner (GCL) in between. As observed, the quantity of leachate increases after rain events making the leachate treatment more expensive. This could be due to areas of weakness in the cover that have developed over time or which date back to its installation. Three different geophysical methods were employed and confronted to detect and assess such damage, and, if necessary, to help choose the most suitable remediation of the cover: Automatic Resistivity Profiling (ARP) which enables a rapid mapping of the entire landfill; the self‐potential method (SP) as one of its sources is water drainage; and electrical resistivity tomography (ERT) to obtain 2D resistivity models. Based on the ARP results revealing high lateral heterogeneities of the superficial cover materials, the SP and ERT measurements were conducted on a limited area. A negative SP anomaly was observed at the top of the landfill, where the cover is the thinnest and the GCL the most damaged, suggesting preferential infiltration under the GCL. The 2D ERT profile showed both vertical and horizontal variations. Comparison with manual auger holes showed that the alternating clayey and sandy layers did not conform to plans for the original cover when it was installed at this site about twenty years ago. Variations in electrical resistivity noticed at the depth of the GCL were attributed to possible damage to the GCL and a greater than expected permeability since the GCL is normally very resistive. The results obtained in this study were important to understand the damage to the cover due to the use of different types and thicknesses of cover materials compared to what was originally planned, and deterioration of the GCL.
The Lascaux Cave has been studied and instrumented for over 60 years. Since 1963, the cave has been increasingly monitored in an effort to order to better examine and manage the various diseases and dissolution linked to environmental factors that have begun to emerge, risking damage to the rock art and the supporting rock. Over the past decade, non-invasive geophysical methods, particularly electrical resistivity tomography, have been employed to study the surrounding massif. This approach combines monthly measurements along profiles and 2D surveys at varying scales, locations and seasons, enabling the reconstruction of 3D models using geostatistics. Analysis of both a decade profile time-lapse and of the 3D models acquired at different periods has improved understanding of water circulation in this unsaturated zone, highlighting temporary reservoirs. Long-term datasets have also been repurposed to, for example, identify the impact of tree felling on resistivity measurements and the massif. Electrical resistivity heterogeneities in 3D models, linked to geological formations and alteration levels, have provided input thermal studies, demonstrating their influence on heat propagation and natural convection within the cave. These findings underscore the critical role of the surrounding massif in preserving the cave.
We have evaluated the uncertainty analysis of the 3D electrical tomography inverse problem using model reduction via singular-value decomposition and performed sampling of the nonlinear equivalence region via an explorative member of the particle swarm optimization (PSO) family. The procedure begins with the local inversion of the observed data to find a good resistivity model located in the nonlinear equivalence region. Then, the dimensionality is reduced via the spectral decomposition of the 3D geophysical model. Finally, the exploration of the uncertainty space is performed via an exploratory version of PSO (RR-PSO). This sampling methodology does not prejudge where the initial model comes from as long as this model has a geologic meaning. The 3D subsurface conductivity distribution is arranged as a 2D matrix by ordering the conductivity values contained in a given earth section as a column array and stacking parallel sections as columns of the matrix. There are three basic modes of ordering: mode 1 and mode 2, by using vertical sections in two perpendicular directions, and mode 3, by using horizontal sections. The spectral decomposition is then performed using these three 2D modes. Using this approach, it is possible to sample the uncertainty space of the 3D electrical resistivity inverse problem very efficiently. This methodology is intrinsically parallelizable and could be run for different initial models simultaneously. We found the application to a synthetic data set that is well-known in the literature related to this subject, obtaining a set of surviving geophysical models located in the nonlinear equivalence region that can be used to approximate numerically the posterior distribution of the geophysical model parameters (frequentist approach). Based on these models, it is possible to perform the probabilistic segmentation of the inverse solution found, meanwhile answering geophysical questions with its corresponding uncertainty assessment. This methodology has a general character could be applied to any other 3D nonlinear inverse problems by implementing their corresponding forward model.