Piotr Cisek

Dr. Piotr Cisek

Department of Energy, Faculty of Environmental and Energy Engineering, Cracow University of Technology, al. Jana Pawła II 37, 31-864 Kraków, Poland
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Energy Conversion and Management
Verified
Journal Article
Closed access
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
PCPiotr Cisek
Piotr Cisek
MPMarcin Pilarczyk
Marcin Pilarczyk
Dawid TalerDawid Taler
Dawid Taler

1 September 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
MBMarco Bittelli
Marco Bittelli
PCPiotr Cisek
Piotr Cisek
EKEva Kroener
Eva Kroener
MPMarcin Pilarczyk
Marcin Pilarczyk
AVAndrea Vallati
Andrea Vallati

1 January 2018 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
PCPiotr Cisek
Piotr Cisek
MRMonika Rerak
Monika Rerak
Dawid TalerDawid Taler
Dawid Taler
RRR. Venkata Rao
R. Venkata Rao
MPMarcin Pilarczyk
Marcin Pilarczyk

1 May 2019 in Energy
Verified
Journal Article
Closed access
Jan TalerJan Taler
Jan Taler
WZWiesław Zima
Wiesław Zima
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
Sławomir GrądzielSławomir Grądziel
Sławomir Grądziel
DTDawid Taler
Dawid Taler
KMKarol Majewski
Karol Majewski

1 October 2020 in Energy Conversion and Management
Verified
Journal Article
Closed access
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
PCPiotr Cisek
Piotr Cisek
EKEwa Kozak-Jagieła
Ewa Kozak-Jagieła
Jan TalerJan Taler
Jan Taler
DTDawid Taler
Dawid Taler
MFMałgorzata Fedorczak-Cisak
Małgorzata Fedorczak-Cisak

6 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
Paweł OcłońPaweł Ocłoń
Paweł Ocłoń
JPJanusz Pobędza
Janusz Pobędza
PWPaweł Walczak
Paweł Walczak
PCPiotr Cisek
Piotr Cisek
AVAndrea Vallati
Andrea Vallati
This paper presents the laboratory test stand that is used for experimental validation of underground power cable system models. Determination of temperature distribution in the vicinity of the cable is the main goal of the study. The paper considers a system of three power cables, situated in the in-line arrangement, and buried in sand. Three electrical heaters of special construction are used in order to simulate the heat flux that is generated in the power cables during their operation. The test stand is designed to be placed in a thermoclimatic chamber, which allows testing the system in various thermal conditions when the ambient temperature changes by 20 °C to 30 °C. Numerical computations of the steady-state temperature fields are performed using the finite element method.