Alexandru Bitoleanu

Prof. Dr. Alexandru Bitoleanu

Department of Electromechanics Environment and Applied Informatics, Faculty of Eletrical Engineering, University of Craiova, 200585 Craiova, Romania
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2012 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Mihaela PopescuMihaela Popescu
Mihaela Popescu
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
VSVlad Suru
Vlad Suru
This paper presents a three-phase three-wire shunt active power filtering system based on two level voltage source inverter which is intended to compensate both current harmonic distortion and reactive power under nonideal voltage conditions. The concepts of the p-q theory are used to calculate the reference compensating current according to the compensation strategy. An improvement in an existing phase-locked loop circuit is proposed to handle the shape of the small amount of additional current needed to cover the power system losses. In the dc-voltage loop, an optimal set point value which minimizes the harmonic distortion of the supply current and depends on power to be compensated is also proposed. Digital signal processor based implementation of the whole control system is described with details on the developed experimental platform dSPACE DS1103 for rapid prototyping. Experimental results obtained from a 15 kVA laboratory setup verify the effectiveness of the active filtering system.

21 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
Mihaela PopescuMihaela Popescu
Mihaela Popescu
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
This study is focused on the topical issue of increasing the energy efficiency in DC railway systems, in the context of global concerns for reducing the CO2 emissions by minimizing the energy consumption and energy loss. The main achievements in this complex issue are synthesized and discussed in a comprehensive review, emphasizing the implementation and application of the existing solutions on concrete case studies. Thus, all specific subtopics related to the energy efficiency are covered, starting with power quality conditioning and continuing with the recovery of braking energy, of which a large part is lost in the classic DC-traction substations. The solutions of onboard and wayside storage systems for the braking energy are discussed and compared, and practical examples are given. Then, the achievements in transforming the existing DC-traction substations in reversible substations with capabilities of power quality improvement are systematically reviewed by illustrating the main results of recent research on this topic. They include the equipment available on the market and solutions validated through implementations on experimental models. Through the results of this extensive review, useful reference and support are provided for the research and development focused on energy efficient traction systems.

10 April 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Mihaela PopescuMihaela Popescu
Mihaela Popescu
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
APAlexandra Preda
Alexandra Preda
This paper concentrates on the LCL filter with damping resistance intended to connect the shunt active power filter of an active dc-traction substation to the point of common coupling with the transmission grid. In order to find design conditions and conceive a design algorithm, attention is directed to the transfer functions related to currents and the associated frequency response. The mathematical foundation of the design method is based on meeting the requirements related to the significant attenuation of the high-frequency switching current, concurrently with the unalterated flow of the current that needs to be compensated by active filtering. It is pointed out that there are practical limitations and a compromise must be made between the two requirements. To quantify the extent to which the harmonics to be compensated are influenced by imposing the magnitude response at both highest harmonic frequency to be compensated and switching frequency, a performance indicator is defined. As an additional design criterion, the damping power losses are taken into consideration. The validity and effectiveness of the proposed method are proved by simulation results and experimental tests on a laboratory test bench at small scale reproducing the specific conditions of a dc-traction substation with six-pulse diode rectifier.

24 November 2016
Verified
Conference Paper
Closed access
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
Mihaela PopescuMihaela Popescu
Mihaela Popescu
VSVlad Suru
Vlad Suru
This paper is focused on the optimal design of the controllers in an active filtering and regeneration system for DC railway traction substation. The control algorithm of the system is based on the indirect current control method and uses two closed loops with PI controllers: an outer one for the DC voltage control and the other for the grid current control. In order to perform the energy regeneration function during the braking process, the filtering and regeneration system is connected to the power grid by a regeneration transformer. Thus, comparative with the direct coupling and direct current control technique, the transfer functions of the system are different. The DC voltage controller is tuned in accordance with the Modulus Optimum criterion and the grid current controller is tuned by the Symmetrical Optimum criterion. In order to verify the operation of the system and assess its performance, detailed computer simulation studies were conducted using the Matlab/Simulink package. The practical case of the 12-pulse parallel rectifier in the traction substation is taken into consideration. The simulation results are presented to prove the validity of the proposed procedure of the controllers' design.

1 October 2013
Verified
Conference Paper
Closed access
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
Mihaela PopescuMihaela Popescu
Mihaela Popescu
The paper is focused on the presentation of the different theories of powers and current decomposition methods in the compensating current calculation for three-phase three-wire shunt active filtering systems. The decomposition methods are grouped into two categories, depending on the type of coordinate system used in the processing measurements involved in calculations. The former is based on the phase coordinates system and includes: the theory of Fryze, the theory of Fryze-Buchholz-Depenbrock, the so-called generalized theories of instantaneous reactive and non-active powers, the Currents' Physical Components Theory (CPC) and the Conservative Power Theory (CPT). The latter refers to the orthogonal reference frame-based approaches such as the p-q theory and id-iq method. The applicability of each theoretical approach in the control of a shunt active power filter was analyzed. A summary highlighting the applicability under non-sinusoidal voltage and the main performance of each method is performed. Next, our platform for testing the control strategies of shunt power filters, based on DSP DS1103 system, is presented. An implementation on a dSpace 1103 DSP system of the theories presented above and some experimental results are given in the second part of the paper.

1 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
Mihaela PopescuMihaela Popescu
Mihaela Popescu
Alexandru BitoleanuAlexandru Bitoleanu
Alexandru Bitoleanu
Mihaita LincaMihaita Linca
Mihaita Linca
Constantin SuruConstantin Suru
Constantin Suru
This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.