Redouane Abouqal

Dr. Redouane Abouqal


Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2006 in Annals of Internal Medicine
Verified
Journal Article
Closed access
PDF file
VRVictor D. Rosenthal
Victor D. Rosenthal
DMDennis G. Maki
Dennis G. Maki
RSReinaldo Salomao
Reinaldo Salomao
CACarlos Alvarez-Moreno
Carlos Alvarez-Moreno
YMYatin Mehta
Yatin Mehta
FCfor the International Nosocomial Infection Control Consortium*
for the International Nosocomial Infection Control Consortium*
Health care–associated infections from invasive medical devices in the intensive care unit (ICU) are a major threat to patient safety. Most published studies of ICU-acquired infections have come from industrialized western countries. In a Centers for Disease Control and Prevention (CDC) National Nosocomial Infections Surveillance (NNIS) System report, the U.S. pooled mean rates of central venous catheter (CVC)–related bloodstream infections, ventilator-associated pneumonia, and catheter-associated urinary tract infections were 4.0 per 1000 CVC days, 5.4 per 1000 mechanical ventilator days, and 3.9 per Foley catheter days, respectively. To ascertain the incidence of device-associated infections in the ICUs of developing countries. Multicenter, prospective cohort surveillance of device-associated infection by using the CDC NNIS System definitions. 55 ICUs of 46 hospitals in Argentina, Brazil, Colombia, India, Mexico, Morocco, Peru, and Turkey that are members of the International Nosocomial Infection Control Consortium (INICC). Rates of device-associated infection per 100 patients and per 1000 device days. During 2002–2005, 21 069 patients who were hospitalized in ICUs for an aggregate 137 740 days acquired 3095 device-associated infections for an overall rate of 14.7% or 22.5 infections per 1000 ICU days. Ventilator-associated pneumonia posed the greatest risk (41% of all device-associated infections or 24.1 cases [range, 10.0 to 52.7 cases] per 1000 ventilator days), followed by CVC-related bloodstream infections (30% of all device-associated infections or 12.5 cases [range, 7.8 to 18.5 cases] per 1000 catheter days) and catheter-associated urinary tract infections (29% of all device-associated infections or 8.9 cases [range, 1.7 to 12.8 cases] per 1000 catheter days). Notably, 84% of Staphylococcus aureus infections were caused by methicillin-resistant strains, 51% of Enterobacteriaceae isolates were resistant to ceftriaxone, and 59% of Pseudomonas aeruginosa isolates were resistant to fluoroquinolones. The crude mortality rate for patients with device-associated infections ranged from 35.2% (for CVC-associated bloodstream infection) to 44.9% (for ventilator-associated pneumonia). These initial data are not adequate to represent any entire country, and likely variations in the efficiency of surveillance and institutional resources may have affected the rates that were detected. Device-associated infections in the ICUs of these developing countries pose greater threats to patient safety than in U.S. ICUs. Active infection control programs that perform surveillance of infection and implement guidelines for prevention can improve patient safety and must become a priority in every country. *For a list of members of the International Nosocomial Infection Control Consortium, see the Appendix.

1 June 2012 in American Journal of Infection Control
Verified
Journal Article
Closed access
VRVictor D. Rosenthal
Victor D. Rosenthal
HBHu Bijie
Hu Bijie
DMDennis G. Maki
Dennis G. Maki
YMYatin Mehta
Yatin Mehta
AAAnucha Apisarnthanarak
Anucha Apisarnthanarak
KJKushlani Jayatilleke
Kushlani Jayatilleke

1 September 2014 in American Journal of Infection Control
Verified
Journal Article
Closed access
VRVíctor Daniel Rosenthal
Víctor Daniel Rosenthal
DMDennis George Maki
Dennis George Maki
YMYatin Mehta
Yatin Mehta
HLHakan Leblebicioglu
Hakan Leblebicioglu
ZMZiad Ahmed Memish
Ziad Ahmed Memish
DADinh Pham Phuong Anh
Dinh Pham Phuong Anh

1 November 2005 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
YAYounès Aïssaoui
Younès Aïssaoui
AZAmine Ali Zeggwagh
Amine Ali Zeggwagh
AZAïcha Zekraoui
Aïcha Zekraoui
KAKhalid Abidi
Khalid Abidi
RARedouane Abouqal
Redouane Abouqal
Facial expression, upper limb movements, and compliance with mechanical ventilation. Two assessors observed and scored pain simultaneously with the BPS at rest and during painful procedures. The psychometric properties of the BPS that were studied were reliability, validity, and responsiveness. We achieved 360 observations in 30 patients. The BPS was internally reliable (Cronbach α = 0.72). The intraclass correlation coefficient to evaluate inter-rater reliability was high (0.95). Validity was demonstrated by the change in BPS scores, which were significantly higher during painful procedures, with averages of 3.9 ± 1.1 at rest and 6.8 ± 1.9 during procedures (P < 0.001), and by the principal components factor analysis, which revealed a large first-factor accounting for 65% of the variance in pain expression. The BPS exhibited excellent responsiveness, with an effect size ranging from 2.2 to 3.4. This study demonstrated that the BPS can be valid and reliable for measuring pain in noncommunicative intensive care unit patients....

24 April 2008 in Critical Care
Verified
Journal Article
Open access
PDF file
KAKhalid Abidi
Khalid Abidi
IKIbtissam Khoudri
Ibtissam Khoudri
JBJihane Belayachi
Jihane Belayachi
NMNaoufel Madani
Naoufel Madani
AZAicha Zekraoui
Aicha Zekraoui
RARedouane Abouqal
Redouane Abouqal
Introduction: Eosinopenia is a cheap and forgotten marker of acute infection that has not been evaluated previously in intensive care units (ICUs). The aim of the present study was to test the value of eosinopenia in the diagnosis of sepsis in patients admitted to ICUs. Methods: A prospective study of consecutive adult patients admitted to a 12-bed medical ICU was performed. Eosinophils were measured at ICU admission. Two intensivists blinded to the eosinophils classified patients as negative or with systemic inflammatory response syndrome (SIRS), sepsis, severe sepsis, or septic shock. Results: A total of 177 patients were enrolled. In discriminating noninfected (negative + SIRS) and infected (sepsis + severe sepsis + septic shock) groups, the area under the receiver operating characteristic curve was 0.89 (95% confidence interval (CI), 0.83 to 0.94). Eosinophils at <50 cells/mm3 yielded a sensitivity of 80% (95% CI, 71% to 86%), a specificity of 91% (95% CI, 79% to 96%), a positive likelihood ratio of 9.12 (95% CI, 3.9 to 21), and a negative likelihood ratio of 0.21(95% CI, 0.15 to 0.31). In discriminating SIRS and infected groups, the area under the receiver operating characteristic curve was 0.84 (95% CI, 0.74 to 0.94). Eosinophils at <40 cells/mm3 yielded a sensitivity of 80% (95% CI, 71% to 86%), a specificity of 80% (95% CI, 55% to 93%), a positive likelihood ratio of 4 (95% CI, 1.65 to 9.65), and a negative likelihood ratio of 0.25 (95% CI, 0.17 to 0.36). Conclusion: Eosinopenia is a good diagnostic marker in distinguishing between noninfection and infection, but is a moderate marker in discriminating between SIRS and infection in newly admitted critically ill patients. Eosinopenia may become a helpful clinical tool in ICU practices.

1 June 2009 in Seminars in Arthritis and Rheumatism
Verified
Journal Article
Closed access
FAFadoua Allali
Fadoua Allali
SASihame El Aichaoui
Sihame El Aichaoui
HKHamza Khazani
Hamza Khazani
BBBoubker Benyahia
Boubker Benyahia
BSBouchra Saoud
Bouchra Saoud
NHNajia Hajjaj-Hassouni
Najia Hajjaj-Hassouni